Building Inspection, Diagnosis & Repair Info

Sulphur bacteria stains in toilet tank (C) Daniel FriedmanWater Supply, Wells, Pumps & Tests

  • POST a QUESTION or COMMENT about installing, diagnosing, repairing, or replacing all of the components and controls for private well water systems.

This page provides an index to key articles about water supply systems installation, diagnosis, repair of wells, well pumps, water tanks.

These water, well, and water supply equipment articles answer inspection, diagnosis, and repair questions about the building water supply sources and equipment including water testing, water piping, water pumps, water wells, & water tanks.

Page top photo: orange brown water coming out of this bath tub faucet was traced to a combination of water having been unused or not run for several months while the home sat empty, combined with a whole house plumbed with rusted galvanized iron piping.

But take care: water color or odors (or test results) can point to a problem at your water source and may mean that the water unsafe to drink.

This water supply home page lists key articles on all building water supply topics including wells, water supply pumps, water tanks, water testing and water treatment equipment.

Page top photo: black muck and stains in this toilet tank may be caused by bacterial contamination.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Water Information Topics Organized Here

Photograph of  a modern steel well casing and cap extending properly above grade level and properly capped. You can see from
the gray plastic conduit that electrical wires enter the well, informing you that this well is served by an in-well submersible well pump.

Here we describe installing or repairing systems for delivering water to buildings, such as well pumps, pump controls, water filters, water heaters, water pressure problems, water supply piping, water softeners, water tank types, leaks, problems, repairs, water quality, water quantity, water contaminants, water testing, water treatment equipment, all types of wells, well piping, well controls.

The article series outlined below starts by organizing problems into categories. Each of the water supply system categories listed below is a link that will provide a list of helpful troubleshooting & repair articles.

To find what you need quickly, if you don't want to scroll through this index you are welcome to use the page top or bottom SEARCH BOX to search InspectApedia for specific articles and information.

Article Series Contents

Best bet for getting help with water related topics: use the search box found near the top or bottom of any InspectApedia article.

...

Water Tests, Water Contamination Limits, Drinking Water Testing Procedures

Photograph of  a modern steel well casing and cap extending properly above grade level and properly capped. You can see from
the gray plastic conduit that electrical wires enter the well, informing you that this well is served by an in-well submersible well pump.This page lists InspectApedia articles helpful in the diagnosis & testing of all types of drinking water contaminants, and in diagnosing & fixing water supply quantity and quality problems: wells, pumps, pipes, water tanks, water pressure, water flow.

How do we stop getting rusty water at the bath tub"

4/29/2014 john popa

Rusty water is coming from hot water in bathtub that is never used. Also it's coming from another sink. All of this was found during a home inspection. We have found nothing.

Inspector suggested could be a issue with the hot water heating coil. We think it is from non-use. Should we clean out the pipes using an acid wash? Can you make some suggestions? [This Q&A originally appeared at CLOGGED PIPES / TANKLESS COIL DE-SCALE]

Reply:

John, Don't do anything yet. If the home has galvanized iron pipes and water sat in piping without flowing for some time, rusty water would be no surprise and should flush out with use. An acid wash has other risks including toxicity - not something to undertake lightly.

And tankless coil tubing is copper, not likely to be a source of red rusty water.

I took the photo of reddish brown water running into a bath tub shown at the top of this page under just the same conditions as you describe. The home had galvanized iron pipes and had been unoccupied for many months. The ugly water flushed out and that was the end of the discoloration complaint.

As long as you are not seeing the same discoloration elsewhere, the unused pipe theory holds water.

Watch out: there may be other implications: galvanized pipes in an older home mean new piping is in your future.

Galvanized iron pipes are often nearing end of life and may be partly clogged by rust and scale in both the water supply piping and water drain piping - leading to a costly but ultimately necessary expense.

...

Well water contamination issues, questions, answers

(Sept 2, 2011) Frances Franconi

Our well came back with coliform and ecoli and disinfecting did not clear it up. We have had a lot of rain lately. We have had this well for some time. What could cause this issue?

(Nov 5, 2012) Sandra Sanders

We tried to shock our well with clorox bleach after finding out we had e coli in our well. I believe we used too much, it's been days and is still very strong. What can we do?

Reply: persistent bacteria problems are different from persistent bleach problems: here's dealing with each:

Persistent coliform and e coli in a well may be from

- surface runoff leaking into the well

- nearby septic system failure leaking in to the aquifer

- or sometimes inadequate well and plumbing cleaning/shocking

I'd look closely at the numbers on the bacteria test results as that can help diagnose the problem. If the starting count is high, shocking doesn't usually fix anything and we look for either a source of contaminants leaking into the well or we decide the aquifer is contaminated.

In any case a well water disinfection treatment system will be needed to assure potable water.

Watch out: where surface water leakage into a well brings bacteria it might bring chemicals or other contaminants along too.

Sandra: indeed improper well shocking procedure using solid bleach tablets or pool tablets, or improper installation of chlorine into the well can make it hard to flush out later. If you poured straight clorox down into the well you may have coated rusty well casing sides, piping, etc. with a too-strong bleach solution. Perhaps connecting a garden hose to an outside faucet and recycling water a bit to flush down the well casing sides and well piping followed by a flush-out will help.

Also, if you introduced bleach-disinfected water into a well water pressure tank or water heater tank you may need to drain those completely to speed the bleach flushout procedure.

...

Water odor complaints - smells like oil

I had a well put down in Dec. and when my home was put in the water was truned on and it had a bad smell and you cann't drink it. It smelled like oil. (Jan 15, 2012) Neater Poole

Reply:

Neater Poole, the oil contaminants in your well might be left from the drilling process and if so can be flushed out;

It is normal to TEST the water delivered by a new well, both a flow rate test and a rather broad spectrum of contamination tests to be sure the water is potable and the source is not contaminated.

Check to see if those tests were done when your well was drilled.

Watch out: hydrofracking and oil and gas well drilling operations in some areas have been related to oil and even gas odors in water wells nearby, though more often contamination issues seem to track to the disposal of drilling wastewater.

See ODORS IN WATER, CAUSES & CURES

...

Water Supply Piping, & Drain Piping

Photograph of  this interesting double s-trap. (C) Daniel Friedman at InspectApedia

...

Water Tanks: installation, adjustment, troubleshooting, repair of water storage tanks & water pressure tanks

Photograph of a 1-line jet pump (shallow well) and water softener

...

Water Treatment Equipment: water disinfection, water filters, water purifiers, water softeners, water odor removal

...

Water Pumps, Pump Controls, Water Pressure, troubleshooting, repairs

...

What do we do if The well pump runs, but we get air, not water

Two months ago I started having problems with our water well. The first thing to happen was the pressure switch caught fire, it was 25+ years old, I replaced it. Then I had the problem of the well pump kicking on and off every few seconds so I had to adjust the air in the air tank.

Everything was fine for a month, then last week we started getting air in the lines, at first it was just a little air but as time went on there was more and more air until there was more air than water coming out of the faucets.

Two days ago I turned on the faucet and just a trickle of water was coming out, I went outside, looked at the pressure gauge and it was at 20 pounds and the pump was still running.

I turned off the pump, checked for leaks in the house as well as all around the well housing to the home, no leaks. I left the pump off for a hour or so because I thought the water level maybe low, 20 inches of rain this month, didnt really think it would be low but I thought it maybe a possibility.

A hour later when I turned on the pump it still would only go up to 15-20lbs of pressure and the pump was still running.

When I turn off the pump I don't lose any pressure, it stays at 15-20lbs until I use water in the home. I looked again for leaks, didnt find any so I replaced the pressure switch, the pressure gauge, the wires from the breaker box to the pressure switch and the wires from the pressure switch to the other bigger switch.

I thought maybe the wires were bad and not allowing enough current to run the pump properly.

I filed all the points on the bigger switch box and cleaned all the connectors. I tried the pump again, still it will only go up to 15-20lbs of pressure and the pump will keep running.

The well is around 400 feet deep, I opened the top of the well housing and put my ear to it, I don't hear any water leaking back into the well and I can hear the pump running.

We replaced the pump and air tank 5-6 years ago. We have lived here for 20 years and have had only a problem one time with low water levels and that was in the middle of summer with very little rain for months, its always had water.

I also checked the air tank, the rubber thing inside of it is busted or something, I'm getting water out of the air valve on top of the tank. I don't think the air tank has anything to do with the amount of pressure the pump pumps up to the home but it will have to be fixed.

There is no one close that has a pump puller in service, the closest is almost 100 miles away, and its going to take them almost two weeks to get here to check out the problem.

So if anyone has any ideas, suggestions, or anything that maybe able to help please post! It will be greatly appreciated! We have 5 children with no water, its getting kind of crazy! Thank you! - Woody

Reply: Some Water Loss Diagnostic Suggestions for This Case

Usually we start diagnosing a well pump and water problem by focusing first on the obvious, known problem, assuming that the chances of multiple problems happening at once are less likely.

But in fact multiple well pump, water tank, piping, and pump control switch problems can occur in a given interval and might even be related to a single root cause.

If you want to click right over to a diagnostic article

see AIR DISCHARGE at FAUCETS, FIXTURES

But based on what you've said so far, it sounds as if:

1. You need to replace the water pressure tank. A burst bladder in the tank can briefly send air out through faucets and will end up leaving the well pump short cycling on and off as the water tank air charge becomes lost.

A burst bladder in the water tank can also interfere with water entering the tank and it might even interfere with proper operation of the pressure control switch.

2. A short cycling well pump for any cause can burn-up the pump pressure control switch.

On occasion it can also damage the pump itself - which in your case is a submersible down in the well, costly and a lot of trouble to replace. So we ought to be as thorough as we can with the above-ground tests and fixes before pulling the pump out of the well.

3. Some causes of a well pump running on without shutting off include loss of water in the well, a damaged pump, a well piping leak, and a pressure control switch set to a cut-off value higher than the pump can reach.

First swap out that bad water pressure tank and give us a comment back here on what happened.

At WATER PUMP DIAGNOSTIC TABLE you will find a catalog of things to check, and in particular, take a look

at WATER PUMP WONT STOP RUNNING

See WATER PRESSURE LOSS DIAGNOSIS & REPAIR for our complete diagnostic series.

Or choose one of the water pressure diagnosis and repair starting points listed at the beginning of this section.

...

Water Pump switch was broken, how do I get it going again?

Loss of electrical power to the well pump?

Reader Amy asks: Concrete blocks from the well pit wall fell onto my pump and pressure control switch, smashing everything. I'm trying to get it working again. How do I fix-up and get the pump switch going?

Please the power supply for my pump isnt on. so i ran a cord from my meter box to the pump. it got wet when it stromed and shorted out and melting the breaker on the pump. i replaced it and hooked back up my cord. nothing. i have tested the cord its give the electrity. what is wrong and what do i need to do help. - (Apr 2, 2012) charity

Reply: your pump pressure control switch may need replacement

Amy, take a look at WATER PUMP PRESSURE CONTROL SWITCH to see details on how these switches work, are wired, and are repaired or replaced. If the blocks broke off the switch from its mount, you'll probably find it easier and more reliable to just replace the switch and its mounting tubing or hardware.

Charity, considering that you have already risked death by electrocution once by your pump wiring, I hope you'll leave it off and hire a licensed electrician. It's no joke that you could kill yourself or someone else.

...

Water pressure loss diagnosis: the water pressure dropped throughout the whole house and the pipes are humming

What would cause a water pressure drop throughout whole house and after runs a little bit a loud humming sounds is produced through the pipes - anon reader

I just replaced my old water tank with a new "pressurized" tank. Now, when I take a shower and the pump hits the low/pump on pressure of 40 psi, I loose pressure (almost to a trickle) in the shower and the water temperature fluctuates. I did not have this problem with the old tank. What could be causing this? (Nov 30, 2011) mikebarber

Reply: look for a well or pump problem; humming may be transmitted from an aboveground pump.

Anon reader - About a water pressure drop throughout the whole house and humming pipes: the observation that it's the whole house that's affected argues that the problem is with your well or pump. But with no other information a diagnostic guess would be just too speculative.

See WATER PRESSURE LOSS DIAGNOSIS & REPAIR

or WATER PRESSURE PROBLEM DIAGNOSIS TABLE to see our diagnostic guide for loss of water pressure in a home.

Mike, we saw this question on another InspectApedia page just recently. If I recall, the reply could only be a speculation that offered some things to check:

If you replaced the pressure tank but kept the old pressure control switch, debris stirred during the plumbing work may have clogged the pressure sensing switch mounting nipple (that small diameter pipe) or the bottom of the switch itself, causing it to fail to respond to the pressure drop.

Try tapping on the switch, and also watch the pressure gauge at the pressure tank. Or replace the switch and its mounting nipple.

The fluctuating water temperature might be related to changes in the water flow rate through your water heater, especially if you're using a tankless coil to make hot water.

Reader follow-up:

Thanks Daniel: Yes I did ask the question on another page and couldn't figure out how to get back to it (I bookmarked this page).

The pressure control switch is mounted on the Sears Shallow Well Jet Pump (3/4 hp - 40 to 60 psi). There is no fitting on the tank since it is a pressure/bladder tank. There is a small black tube going from the pump body to the bottom of the pressure control switch/box. I did remove it from the pump at one point.

I have since drained the pump, tank and water lines via what looks like a car radiator drain cock on the bottom of the pump (hopefully clearing any debris or air from the PCS line). The pressure gauge is on the pump in the opening designated as the "priming port" in the pump manual.

This pressure gauge has always been there.

Recently I noticed that as the water runs and the pressure drops the gauge gets to 49 psi and stops, then suddenly drops to 40 psi and the pump turns on. It takes on average 4 mins and 15 secs for the pressure to return to 60 psi.

The tank manufacturer tells me that this is a 19 gal/ 45 gal equivalent with a 5.9 gal "draw down" which should be the same as my old steel 45 gal tank.

I have a gas fired "normal" water heater and I suspect the temperature change is as you suggest, just exacerbated because of the extremely low water pressure.

I will take the pressure switch hose and fittings off to make sure they aren't clogged (do you think the sudden pressure drop is a symptom of this?) mikebarber

...

Water Wells, Cisterns, Springs: installation, troubleshooting, repairs & maintenance

Schematic of a drilled well (C) Carson Dunlop Associates

...

What to do if our water filter plugs up after shocking the well; sand and debris in the water supply

After shocking my well, i had to replace my whole house water filter about 6 to 8 times, because it would plug up with black sediment. Is this normal? - Tom

And from another:

We are having issues with our well. Earlier in the season, we kept getting sand in our water.

Everyone kept saying "its the water table" because we were in a draught. But, we've been getting rains for the past month or so fairly regular and now we are getting mud in our water. A filter that should last about 6 months is barely making it for 2 weeks. Any ideas. (Oct 23, 2012) Sheila

Reply:

Tom, no it's not normal for shocking the well itself to cause the water filter to clog up.

If by shocking the well you simply poured a bleach solution into the well casing, that alone wouldn't explain the debris clogging at your water filter, but if you followed our recommended procedure of washing down the casing sides with recycled chlorinated water then indeed you may have stirred up debris in the well.

After replacing the filter a couple of times this problem should stop.

If the clogging of your water filter continues then I suspect that something has happened either to the well casing (a crack or opening admitting dirt), the aquifer (changed, perhaps due to nearby drilling or blasting), or the well piping (a leak).

If the problem persists you'll need to install a higher capacity sediment filter system on your water supply.

See FILTERS, WATER.

Watch out: the conditions you describe would lead me to also have a bacteria test for well contamination.

Sandra

Shut off water, drain your pressure tank and hot water tank, run water to an outside faucet to clear the well, then refill tanks and flush piping.

...

Water Pressure Diagnosis & Repair

...

Well Water Quantity - how much water can we get? There's not enough water

Photograph of an open well casing

...

Well Water Quality - what's in the water? Some water is not so good to drink

Water Well Bore Alignment & Plumbness

This discussion moved to its own page

at WELL BORE ALIGNMENT PLUMBNESS STRAIGHTNESS - standards, test procedures, why well bore alignment is important

...




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

How to install a replacement well tank and pump

Well cycling (C) InspectApedia.com DavidJI changed out my well tank and pump. They were completely different in design, new versus old. The new system cycles when the pressure reaches 50. No leaks to speak of.

Also does my well pump need to be higher than a couple inches above the supply/suction line.

Switch is mounted on pump. Do I need to move it to the t valve since that is the new style?

At a loss as to why the pump cycles.

I also have a smaller diameter hose for the water out from pump to tank.

That is the supply line is 1 1/4” and the pressure line to the tank is 1" until it gets to the check valve then it is 1 1/4”.

Is this a problem?

I also had to go to 3/4” 6 inches before th check valve. Maybe that’s the problem? On 2022-10-05 by David J

by InspectApedia-911 (mod)

What is the pressure tank pre-charge pressure, and did you set that with the tank empty?

by David J

@InspectApedia-911,

Yes I pre-charge the tank to 28 psi because my switch is a 30/50 psi switch

by InspectApedia-911 (mod)

@David J,

And just to be sure we've got this exactly right, the pre-charge is set when there's no pressure on the system. Otherwise you can get fooled about what the recharge actually is.

So if we are confident that the pre-charge is correct and that there is no valve or check valve that's blocking the flow between the pump and the pressure tank, and the pump is rapidly short cycling, I suspect that the pump output rate is getting ahead of what it can flow through the smaller diameter piping between the pump outlet and the pressure tank inlet.

by David J

@InspectApedia-911,

I suspect the same and am taking steps to change it now.

I will let you know how that goes with an update.

by InspectApedia-911 (mod)

@David J,

Thanks, do let us know what do you find as that will certainly help others who read this article.

by David J

@InspectApedia-911,

Hooray! It’s works as intended now. Thanks for your quick knowledge to guide us all.

by InspectApedia (Editor) - new pump is rapidly short cycling

@David J,

Thank you for following-up; am I right that you increased the pipe diameters between pump and tank?

Sand/shallow point well won't prime

I have a cottage where there is a sand/shallow point well installed. I try to prime the pump, but nothing happens. Where should I start with trying to get to the main issue here? Ive had plumbers look at it- they get it working after a lot of priming and then eventually stops producing any water. On 2022-03-16 by Kami D

by Inspectapedia Com Moderator -

@Kami D,

Rather than trying to give a complete answer here, please first take a look at

REPEATED LOSS OF WELL PRIME

where we provide common causes of lost well prime and step by step diagnosis and repair.

Start there and let us know if you have additional questions.

Water flow slows to a trickle in cycles - what's wrong?

I have a double jet pump for a well that appears to be low yield. If our bathtub faucet is fully open, the water trickles to nothing after about 1 minute. After a break of a minute or two, water returns, and we can proceed normally for all other uses (dishwasher, shower, toilets, other faucet etc.).

We have never lost water in any permanent way - it just stops momentarily when we use water too quickly. It has been this way for the entire 13 years that we have been living in the house.

Recognizing that the "proper solutions" would probably include getting a holding tank or drilling a new well, are there adjustments we could make (to either our pump system or faucets that would reduce the severity of the problem?

I am wondering, for example, if we could slightly restrict the flow of water out of our pressure tank so that water is used a bit slower, or potentially decrease the differential of the cut in/cut off settings so that the pump starts running a bit sooner.

Right now, the pump cuts in at about 26 PSI, and cuts out at about 36 PSI. Assuming no faucets are on, it takes about 8 minutes from when the pump cuts in for it to reach 36 and cut out. On 2021-12-09 by Karl Saidla

by Inspectapedia Com Moderator - low water yield may be due to pressure control switch that is clogged

@Karl Saidla,

Because you say that your well delivers plenty of water once it's gotten going, I suspect that that initial problem may not be a well flow rate but rather a pressure control switch that is clogged and not responding to the initial drop in water pressure.

Try replacing the switch and also clearing or replacing the tubing or pipe that conducts water pressure to the switch sensor port.

Diagnose & fix no water going into pressure tank

Water well troubles. Pulled the lines from the well, changed out foot valve, galvanized fittings, which had a leak, installed the well cap back on. Got a new well pump, now getting water to the faucet's/toilets, but no water going into pressure tank.

Having to turn switch from the pump on and off in order to get water and turn off water. The psi remains at 30 when pump switch is turned off. Looking for solutions to what the problem could be now? Thank you in advance. On 2021-11-17 by Trudy Drover

Repair Advice by Inspectapedia Com Moderator -

@Trudy Drover,

Old pressure switch may be debris clogged

No water enters pressure may be a closed valve or a stuck bladder

 

How do I fix a leaky air valve at the water pressure tank

Hi hope you can help me. I have a pressure tank leaking from the bottom fitting as well as water coming out of the schrodier valve at the switch.

The boost pump is attached top the wet side of the tank. Does the tank need replacing and can I just reattach the boost pump? On 2020-08-11 by Bill

by (mod) -

Photo of a water tank air inlet valveBill:

Look closely at the point of leakage; most likely you can remove, apply teflon paste, and reconnect a new fitting.

When it's a leak at the air valve or Schrader valve, look closely: is the leak at the threaded base of the valve?

If so you may be able to tighten the valve or to remove it, apply teflon tape, and re-install it to stop the leak.

If the Schrader valve is leaking at its stem or core, a **temporary** emergency repair is to simply install and tighten a valve stem cap over the open end of the valve.

This is a standard tire valve thread so any auto supplier has these caps as do the tires on your car. (In an emergency, I've borrowed the valve cap off of the car's spare tire.)

For a proper repair, it's possible to replace the Schrader valve stem core - again a standard automobile tire valve part, though on some water systems that use a snifter valve, the schrader valve stem core on that device uses a much weaker spring than an automobile tire valve core.

Exact details of how to repair a leaky water tank air valve are

at WATER TANK AIR VALVE REPAIRS

Help me understand my water and well flow test report

Well flow test report showing flow diminishing over time (C) InspectApedia.com Joan

I’m not sure if you are able to help with this question but I’m really hoping so.

We just received the results of a well flow test on a house we are in the middle of purchasing.

The GPMs started out at 7 but began to drop after 20 minutes. By the end of the two hours test the GPMs had dropped to 3.8. The total flow was 641 which is just over the state requirement if I’m not mistaken and I know the GPM should be at 5 but I’m not sure if that is 5 during the duration of the test or as an average? I’m hoping you can give me some insight on whether I should be concerned.

During the home inspection of the home the inspector tried to fill up the bathtub and it took over an hour and I’m really wondering if the well could be the reason for this. The home is a full three bath house at 3000 square feet.

I've attached the results for you to view

Thank you for your time. On 2020-08-10 by Joan

Answer by (mod) - Well flow test report interpretation

Joan:

"Flow rate" is defined in articles I'll cite below; basically it is not a useful number until you obtain it over a 24 hour period.

Otherwise you're simply exhausting the well - it's like claiming your car can get 80 mpg because you measured the fuel consumption rate after you drove a mile and turned off the engine.

5 GPM is a flow rate that is required for functional flow in the building; your well cannot sustain 5 gpm for more than one hour.

So if sometimes your flow rate is less, then you're depending on water storage to make up the difference; that is, for a low flow or limited flow rate well, a common step is to add a large water storage capacity, allowing the storage to recover at the lower flow rate overnight or during other periods of disuse.

Watch out: A well flow test is often run over a 24-hour period.

Your well flow rate fell from 7 gpm to under 4 gpm after two hours after drawing 600 gallons - about the typical daily water use for three people.

It's not that you couldn't live with this well, because you could, but you're starting off with a rather modest water supply.

You should be concerned, and you should budget for well flow improvement costs or water storage costs.

To understand this topic and thus to equip yourself to discuss it, I recommend reading these two brief articles:

WELL FLOW RATE
- how do we find out well water quantity - well flow rates or draw down tests

WELL FLOW TEST PROCEDURE
- how can a homeowner or home buyer make a simple well water quantity test

 

Well man says the leathers are rotted - what the heck does that mean?

I have just purchased an old brick school house. It has a 2 inch well that we believe is 90+ ft deep. I tried to run the pump and the elcetric motor ran for over 10 minutes without any luck bringing water up. Everything seems to be in working order.

My local well man says it could be the leathers are too worn or the pipe is rotted through as the well is from 1900. I was hoping to revive this well. Any ideas? Can a sandpoint be lowered into this pipe and solve the problem? I only need 4-5 gal / minute On 2020-08-08 by John

by Moderator - Leathers and well bores

90 ft deep wells with a 2in board don't use leathers. Leather was used as a washer on hand pumps that used to be able to pump from a depth of about 20 to 25 feet.

And metal well piping doesn't rot. Wood rots.

So what do you report having been told sounds to me like someone who either doesn't know much about wells or is speaking very carelessly.

In order to try to restore a 90 ft deep 2 in weII service I would start by finding out what's in the well.

That means hiring a more professional well service company who has a well inspection camera. Using the camera, you can find out the condition of the wellbore and whether it is collapsed or damaged and you can also find the depth of the water.

If the well bore used to be in good condition and there's a reasonable volume of water in the bore the next step would be to temporarily try pumping out the well to see if it has a usable flow rate or recovery rate. If it does then you'll probably install a two-line jet pump to provide water from your well.

 

When water requirements far exceed well capability to deliver water we see a huge water storage tank

I work at a facility with 11 buildings on the grounds all of which, will eventually need running water. The buildings are 50+ years old and have not been used in 15-20 years. We are remodeling 1 building at a time and at this time only need to use water in 1 of them.

We have 2 wells only one of which was working and 4 10,000 gallon holding tanks. We recently replaced all the underground pipes running from the well to the buildings.

It's been 1 problem after another. Brand new underground pipes were bursting for no apparent reason And leaks around the pressure pumps, specifically from one of the boosters.

We just installed 4 new pumps and everything was working well for 2 days, and then all of a sudden, there was no water pressure. I walked around the property, looking for evidence of another leak from the underground pipes and could not find any. I turned the swith on the pump off anyway and called the owner.

He called & notified the pump company and said they would be out in morning. They never showed up the next day but instead sent an electrician out to install a flow switch so that when water got too low in one tank, it would automatically switch to another.

Unfortunately, the damage was already done and now my boss has to pay another $20,000 because all 4 new pumps need to be replaced again. My boss is understandably very angry, but thinks I did something to cause this.

All I did was turn the pump off when I noticed there was no pressure. I've never turned it on and know better than to mess with things I know next to nothing about. I dont know if someone from the pump company put this in his head or if he just thinks because I was the only one on the grounds at the time, that I must have caused it.

Apparently, the cause of the low pressure was due to the water level in the holding tank getting too low. The holding tank has tiny holes in the top 1/3 of the tank so it water shoots straight out the holes when the tank is filled over 2/3 from top.

I believe the pump company knew this problem would eventually happen because they knew there was nothing installed to protect the pumps, should the well run dry and that we should not be held liable, after all, they're the professionals.

I believe they are reaming my boss because they believe they have found a money tree.

Apparently this whole ordeal has cost him $120,000.

I dont know if he is exaggerating the cost to me or if this is typical or if he is just dealing with an unethical company, and I dont know enough about wells & pressure pumps and holding tanks to offer my opinion but I feel so strongly that something just isn't right, I'd really appreciate some expert advice. On 2020-07-29 by Sue

by Moderator -

When you see 10,000 gallons of water storage at a site then you know the on-site water requirements far exceeded the ability of the wells on the site to deliver water. Strategy in such a case is to use wells that have a poor weak or slow recovery rate to refill water tanks slowly, typically over a 24-hour period, or at night when not much water is in use.

I can't second-guess your well company who was on site, but from what you have described it seems to me that what was missing was a very common system that uses a type of pump protection switch or device that will turn off a water pump to prevent it from pumping air or running dry. It's running dry that destroys a water pump.

So you can tell your manager that you did exactly the correct thing by immediately turning off the pumps when you saw that there was trouble.

You can add my explanation that unfortunately by the time that could be discovered it may have been too late in that the pumps were already damaged,

and you can add that the original installer short-changed you by not providing protection for the pumps or at the very least testing the well to establish their flow rate to prove that the system that was being installed would work correctly.

I can't really know, but I suspect that the fact that calls weren't returned means that the original installers knew perfectly well that they hadn't done the correct job.

Once you establish that you have functional well you should at least be sure that a well protection devices is part of your new installation. See WATER PUMP PROTECTION SWITCH and other pump protection devices like WELL PIPING TAIL PIECE - other devices that protect a water pump from damage

 

Why have I replaced my well pump 3 times in 10 years?

Hi- I've lived here for 10 years. I am on my 3rd 1.5hp pump, and 2nd 119 gal bladder tank.

Concerned with these higher expenses, I asked the well company what is the best scenario for maximizing well components life while irrigating my yard etc. They recommended getting the well's flow rate output matched to the irrigation output, so that the pump runs continuously without cycling.

I have done this, and the water pressure runs steady at 48psi on each 25 minute irrigation cycle. The pressure switch is at 40/60psi. Is pump cycling more wearing than continuous running?

Does it depend on the water temperature the pump is submersed in? How long the pump runs continuously?Any scenarios better than what I am doing is greatly appreciated! On 2020-07-18 by Jeffy

by Moderator

You will want to check with the pump manufacturers about the properties of the specific pump brand and model that you are selecting or planning to install.

Many pumps can tolerate running continuously for long intervals.

Rapid short cycling on and off is what damages a pump and / or the pump pressure control switch.

You should also consider including a pump protection switch to be sure that your long-running pump doesn't run dry and suffer damage from that condition.

See WATER PUMP PROTECTION SWITCH

How do I test for water hardness

What is the best water hardness kit to buy that will give me a close correct setting for my water softener On 2020-07-11 by Cheryl D

by (mod) -

Cheryl

Thanks for asking about water hardness testing.

Please take a look at WATER HARDNESS: HOW TO MEASURE

where we tested and demonstrated several different types of water hardness tests. The easiest, a simple test strip, properly used, will be fine for your purposes.

How much can a well bore deviate out of vertical?

What is deep well deviation limit from vertical/plumbline .any material for deviation measurement please share

Please I want to know the various standards defined by international groundwater agencies for deep well casing deviation (plumpness limit) from plumbline for 300 ft depth. On 2020-07-05 by Husnain Ahmed

Reply by (mod) -

Ahmed

Please find your question and our detailed reply now at

at WELL BORE ALIGNMENT PLUMBNESS STRAIGHTNESS - standards, test procedures, why well bore alignment is important

Thank you for asking a most helpful question. Let me know if you need more information

...

Continue reading at WATER TESTS for CONTAMINANTS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see WATER SUPPLY SYSTEM FAQs - questions and answers posted originally at this web page

Or see these

Recommended Articles

Suggested citation for this web page

WATER PUMPS, TANKS, TESTS, WELLS, REPAIRS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & Reviewers

In addition to any citations in the article above, a full list is available on request.

  • [1] Drinking Water from Household Wells - PDF, U.S. EPA, Original source last retrieved 2/13/2013, original source: http://www.epa.gov/privatewells/pdfs/household_wells.pdf
  • [2] Salzman, James, Drinking Water: A History, Overlook (2012), ISBN-10: 1590207203, ISBN-13: 978-1590207208,
  • [3] Soll, David, Empire of Water: An Environmental and Political History of the New York City Water Supply, Cornell University Press, (2013), ISBN-10: 0801449901, ISBN-13: 978-0801449901
  • [4] Mithen, Steven, Thirst: Water and Power in the Ancient World, Harvard University Press (2012), ASIN: B00EDZ5OHC.
  • [5] Pabich, Wendy J., Taking on Water: How One Water Expert Challenged Her Inner Hypocrite, Reduced Her Water Footprint (Without Sacrificing a Toasty Shower), and Found Nirvana, Sasquatch Books (2012), ASIN: B00EB0JTB6
  • 1-Bromo-3-chloro-5,5-dimethylhydantoin (C5H6BrClN2O2) is produced world-wide and is also used in cleaners and bathroom disinfectants and deodorizers. Here is an example MSDS for this product, provided by Leisure Time
  • "Bacteria in Drinking Water" - "Chlorine," Karen Mancl, water quality specialist, Agricultural Engineering, Ohio State University Extension. Mancl explains factors affecting the effectiveness of chlorine in water as a means to destroy bacteria and other microorganisms. OSU reports as follows:
    • Chlorine kills bacteria, including disease-causing organisms and the nuisance organism, iron bacteria. However, low levels of chlorine, normally used to disinfect water, are not an effective treatment for giardia cysts. A chlorine level of over 10 mg/1 must be maintained for at least 30 minutes to kill giardia cysts. -- http://ohioline.osu.edu/b795/index.html is the front page of this bulletin
  • "Chemicals and Our Health", Nicholas D. Kristof, New York Times, 16 July 2009, p. 27. This outstanding editorial calls for improvements in public health policy to address phthalates and other environmental contaminants from common chemicals and products in everyday use. - DJ Friedman
  • Crystal Clear Supply provides portable ceramic water filter purifiers and portable reverse osmosis water treatment equipment - see http://www.crystalclearsupply.com/category_s/7.htm
  • Endocrine Disruptor Exchange, Dr. theo Colborn (also see Our Stolen Future).

    From that website: The Endocrine Disruption Exchange, Inc. is the only organization that focuses primarily on the human health and environmental problems caused by low-dose and/or ambient exposure to chemicals that interfere with development and function, called endocrine disruptors. ...

    TEDX's work focuses on the endocrine system, which is the exquisitely balanced system of glands and hormones that regulates such vital functions as body growth, response to stress, sexual development and behavior, production and utilization of insulin, rate of metabolism, intelligence and behavior.

    Hormones are chemicals such as insulin, thyroxin, estrogen, and testosterone that interact with specific target cells. The interactions occur through a number of mechanisms, the easiest of which to conceptualize is through a lock and key arrangement.
  • Giardia exposure limits for drinking water: see www.mass.gov/dep/water/drinking/standards/giardia.htm is the current regulatory exposure limit (your minimum target for sterilization)
  • Health Effects of Chemical Contaminants in Drinking Water, US Environmental Protection Agency,
  • Hydrogen Peroxide warning: US FDA Warning about drinking hydrogen peroxide: www.truthorfiction.com/rumors/h/hydrogen-peroxide.htm This article cites a 2003 entry in Journal of Food and Science on using Hy.Perox to sterilize vegetables, referring to E.coli - NOT to Giardia.
  • Iodine: "Do Iodine Water Purification Tablets Provide an Effective Barrier against Cryptosporidium parvum?", Starke, Jeffrey A., Bowman, Dwight D., Labare, Michael, Fogarty, Elizabeth A., and others, Military Medicine, 25 October 2001 [possibly a later version of this article appeared in 2005 -DF] http://www.amsus.org/military medicine/milmed.htm
  • National Primary Drinking Water Regulations - The complete regulations regarding these contaminants available from the Code of Federal Regulations Website -(United States)
  • Ohio State University article on the concentration of chlorine necessary to act as an effective disinfectant, and the effects of the water's pH and temperature: See http://ohioline.osu.edu/b795/b795_7.html for details.
  • Our Stolen Future: Are We Threatening Our Fertility, Intelligence, and Survival?--A Scientific Detective Story, Theo Colborn, Dianne Dumanoski, John Peter Meyers. Plume-Penguin Publishing, 1997, ISBN 0-452-27414-1., ISBN13: 9780452274143. This book is a seminal work on endocrine disruptors (chemical contaminants having impact at extremely low levels in the environment).

    Recommended by Daniel Friedman, this book is a critical update to the landmark Silent Spring by Rachel Carson and discusses the effects of minute trace amounts of chemical contaminants in the environment.

    The text "Identifies the various ways in which chemical pollutants in the environment are disrupting human reproductive patterns and causing such problems as birth defects, sexual abnormalities, and reproductive failure. Reprint. Tour. NYT."

    Amazon.com Review: By O T (Ontario, BC) - 'Our Stolen Future' is a great introduction to one of the most important scientific discoveries in our time. Having recently completed a thesis project at university on Endocrine Disruptors, I have reviewed hundreds of papers on the subject.

    This book is a good clear overview of the scientific literature on EDs. The authors are experts - Theo Colborn is largely responsible for creating the field by bringing together diverse researchers so they could see the big picture of their work.

    Many of the principle investigators are interviewed and quoted at length on the way chemicals participate in and interfere with delicate hormonal systems in animals (including humans). The major accomplishment of the book is to make an easy-to-follow story out of complex research.

    Many resources are available to help you assess the reliability of this story, and the best thing to do if you have any doubts is read review articles in scientific journals (which are easier to understand than technical papers). The Physicians for Social Responsibility (PSR) have a guidebook for health-care professionals on Endocrine Disruptors, and the US EPA has many reports on the matter. Beware of people or websites who try to 'debunk' this book (or the science behind it) by simply declaring it false, flawed or disproven. There is far too much supporting research for so simple a refutation.

    OPINION: Significant and discussed in this book is the observation that at certain critical points in the development of animals, presumably including humans, exposure to extremely low levels of endocrine disruptor chemicals (EDC's) BPA - Bisphenol-A or BPA, Diethylstilbestrol - DES, dioxins, PCBs, and chemicals used in the production of certain cleansers, dyes, flame retardants, plastics, pesticides, white papers ) perhaps just a few molecules, or in the parts per trillion, is sufficient to cause disruption of the animal's development, including proper sex differentiation, or the lack of it that produced androgynous ducks unable to reproduce under such conditions.

    A endocrine disruptor is a synthetic chemical compound that mimics natural hormones when it is taken into the body of a human or other animal. It "disrupts" the endocrine system by turning on or off normal chemical signals that in turn can affect normal hormone levels, bodily functions, and significantly, the development of embryos. Further, unlike naturally occurring hormones ingested, for example from plants (phytoestrogens), synthetically-generated hormones accumulate in the body and can have a half-life of decades or longer.

    One significance of this finding includes the observation that an important medical effect that occurs with exposure to chemicals in extremely low concentrations means that experiments to test for correlations between chemical exposure and subsequent serious medical problems will be deeply flawed if, for example, the experimental design does not include testing for the presence of the chemical at extremely low levels.

    A related concern is that even if harmful effects from exposure to extremely low concentrations of an endocrine disruptor are occurring, teasing out and proving that relationship can be also extremely difficult.
  • Potable Aqua® emergency drinking water germicidal tablets are produced by the Wisconsin Pharmacal Co., Jackson WI 53037. 800-558-6614 pharmacalway.com
  • [20] SCALE FORMATION in WATER HEATERS and METHODS of PREVENTION free download as [PDF] Krappe, Justus Maximilian, Engineering experiment station. Gas engineering bulletin; no. 6; Research series; no. 74; On cover: Engineering bulletin, Purdue university. Vol. xxiv, no. 3a. June, 1940 (Layfayette Indiana) commonly referred to in some references as "Purdue University Bulletin No. 74" - thanks to researcher Robyn Goldstein for the full citation. LCCN: 40028844 & OCLC: 1038544 - Water analysis, water softening, hot-water supply. 27pages.

    You can also obtain this document through your local library. (full copy file at InspectAPedia 3/31/2010) Purdue B074 can be hard to locate online.

    Also Bradford White Corporation (a manufacturer of water heaters) previously published

    SCALE FORMATION in WATER HEATERS - EXCERPTS [PDF] from that document made available by Purdue University.
  • Silent Spring, Rachael Carson, Mariner Books; Anv edition (October 22, 2002), ISBN-13: 978-061824906.

    Amazon.com Review: Silent Spring, released in 1962, offered the first shattering look at widespread ecological degradation and touched off an environmental awareness that still exists.

    Rachel Carson's book focused on the poisons from insecticides, weed killers, and other common products as well as the use of sprays in agriculture, a practice that led to dangerous chemicals to the food source. Carson argued that those chemicals were more dangerous than radiation and that for the first time in history, humans were exposed to chemicals that stayed in their systems from birth to death. Presented with thorough documentation, the book opened more than a few eyes about the dangers of the modern world and stands today as a landmark work.
  • UNESCO: World Water Assessment Programme [ copy on file as /water/Water_Assessment_UNESCO_129556e.pdf ] - , Executive Summary, UNESCO Publishing, Secretariat: C/O UNESCO/Division of Water Sciences, 1 Rue Miollis, F-75732 Paris Cedex 15, Tel: +33.1.45.68.39.28, Email: wwap@unesco.org, websearch 09/10/2010 original source: http://unesdoc.unesco.org/images/0012/001295/129556e.pdf - Quoting:

    This report is organized in six main sections: a background, an evaluation of the world’s water resources, an examination of the needs for, the uses of and the demands on water (‘Challenges to Life and Well-Being’), a scrutiny of water management (‘Management Challenges’), seven representative case studies highlighting different water scenarios, and conclusions and annexes.
  • US EPA: list of drinking water contaminants: see http://www.epa.gov/safewater/contaminants/index.html
  • UV light: This patent application for UV light sterilization www.patentstorm.us/patents/6565803.html Lists good references on water purification for Giardia et als
  • Access Water Energy, PO Box 2061, Moorabbin, VIC 3189, Australia, Tel: 1300 797 758, email: sales@accesswater.com.au Website: http://www.accesswater.com.au/

    Moorabbin Office: Kingston Trade Centre, 100 Cochranes Rd, Moorabbin, VIC 3189

    Australian supplier of: Greywater systems, Solar power to grid packages, Edwards solar systems, Vulcan compact solar systems, water & solar system pumps & controls, and a wide rage of above ground & under ground water storage tanks: concrete, steel, plastic, modular, and bladder storage tanks.
  • Grove Electric, Typical Shallow Well One Line Jet Pump Installation [PDF], Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, Vancouver WA 98665 www.grovelectric.com - web search -7/15/2010 original source: http://www.groverelectric.com/howto/38_Typical%20Jet%20Pump%20Installation.pdf
  • Grove Electric, Typical Deep Well Two Line Jet Pump Installation [PDF], Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, Vancouver WA 98665 www.grovelectric.com - web search -7/15/2010 original source: http://www.groverelectric.com/howto/38_Typical%20Jet%20Pump%20Installation.pdf
  • Crystal Clear Supply provides portable ceramic water filter purifiers and portable reverse osmosis water treatment equipment - see http://www.crystalclearsupply.com/category_s/7.htm
  • Handbook of Disinfectants and Antiseptics, Joseph M. Ascenzi (Editor), CRC, 1995, ISBN-10: 0824795245 ISBN-13: 978-0824795245 "The evaluation of chemical germicides predates the golden age of microbiology..."
  • Potable Aqua® emergency drinking water germicidal tablets are produced by the Wisconsin Pharmacal Co., Jackson WI 53037. 800-558-6614 pharmacalway.com
  • Principles and Practice of Disinfection, Preservation and Sterilization (Hardcover)
    by A. D. Russell (Editor), W. B. Hugo (Editor), G. A. J. Ayliffe (Editor), Blackwell Science, 2004. ISBN-10: 1405101997, ISBN-13: 978-1405101998.
  • U.S. Army Field Manual 21-10, Field Hygiene and Sanitation, 1988, web search 07/02/2010, original source: http://www.enlisted.info/field-manuals/fm-21-10-field-hygiene-and-sanitation.shtml

    The purpose of this manual is to assist individual soldiers, unit commanders, leaders and field sanitation teams in preventing disease and environmental injuries.

    The manual provides information on preventive medicine measures (PMM) to the individual soldier as well as essential information for the unit commander, unit leaders, and the unit field sanitation team on applying unit level PMM.
  • When Technology Fails, Matthew Stein, Chelsea Green Publisher, 2008,493 pages. ISBN-10: 1933392452 ISBN-13: 978-1933392455, "... how to find and sterilize water in the face of utility failure, as well as practical information for dealing with water-quality issues
  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested

    CONTINUE READING or RECOMMENDED ARTICLES.


ADVERTISEMENT