This article describes how toxic or allergenic mold is removed from buildings - mold cleanup, or mold remediation.
We discuss how to physically remove problem mold (don't just spray over it), what cleaners can be used for mold removal, and use of bleach in mold cleanup and removal jobs.
We also list related mold cleanup or remediation articles that address special problems such as mold odors, mold removal from irregular surfaces, and stains or odors on roofs or in cars.
The steps in this document will be sufficient for many building owners who want to do their own mold investigation, mold testing, mold cleanup, and mold prevention in their home or office. The photos at the top of this page show the results of media blasting moldy wood surfaces.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
This article provides a succinct guide to mold cleanup for homeowners or tenants.
Protect the occupants and yourself:
from mold, demolition dust, debris, cleaning chemicals, etc.
Where a large area of cleanup is involved (more than 30 sq.ft.) a professional is usually called to establish negative air in the work area and to install containment barriers of plastic or other material to protect cleaner areas of the building from cross-contamination during the cleanup.
If you used a building environmental specialist to inspect and define the scope of work, you should have baseline mold test samples of both the work area and other building areas which will permit you to state definitively, at the end of the cleanup, whether or not the cleanup has caused cross-contamination of other building areas.
The spotless cleaning produced for the second photo above was obtained by using a professional who used
MEDIA BLASTING for MOLD REMOVAL to clean these surfaces. Such measures may be needed for large or complex surfaces, but quite often the necessary steps are less technical and less onerous, as we describe next.
Clean or remove mold and moldy debris:
The most succinct Mold Remediation or Mold Cleanup Guidelines one could
state would be this: the objective is not to sterilize your environment or "kill" mold, steps which are ineffective anyway - the operative words are "clean" or
"remove" problem mold and then to correct its cause.
If the total square feet of moldy material is less than 30 sq.ft.,
it is reasonable to handle the mold cleanup as an ordinary building cleaning or renovation procedure - hiring experts to establish negative air, dust containment, etc. is not required, but you should still take steps to minimize cross contamination in the building and to protect yourself and other occupants from moldy dust and debris.
If the total contiguous square feet of moldy material is large (more than 30 sq.ft.),
then you should consult a professional to inspect the building, find all of the problem mold areas, and to prepare a mold cleanup or mold remediation plan which will guide the mold remediation company (who should be a totally independent contractor in order to avoid conflicts of interest).
The mold consultant should also advise on the steps needed to prevent future mold growth - fix the causes of mold contamination.
If the mold cleanup is a costly project you should have the independent mold consultant perform a thorough visual and physical inspection of the building after the mold cleanup to assure that it was effective.
Note: some sources have amended the 30 square feet rule to 10 square feet as the size suitable for homeowner cleanup.
Remove and dispose of moldy items that cannot be effectively cleaned:
Moldy drywall, paneling, trim, carpets,
boxes, junk, are removed and disposed-of as construction debris or trash, either because the item cannot be effectively cleaned, or in some cases because the cost of cleaning exceeds the value of the object.
Be sure to remove building insulation that has been wet or smells moldy or has
been exposed to high levels of airborne mold.
See INSULATION MOLD CONTAMINATION TEST.
Usually moldy drywall and other debris can be disposed-of as ordinary construction debris or trash.
Scrubbing moldy surfaces - no sprays, no ozone, no sterilization:
We're talking about scrubbing here. It's the physical removal of moldy or allergenic debris that's important, not the surface sterilization.
The second we permit someone to "spray for mold" we can count on them to fail to do an adequate mold cleanup.
And if the moldy surface to be cleaned is "cleanable" so irregular or inaccessible as to make physical wiping or scrubbing impractical, you may want to
consider MEDIA BLASTING for MOLD REMOVAL.
What to use to clean off mold from all of the exposed hard, cleanable surfaces: to clean off a moldy surface, you could use simple clean water, soapy water, spray cleaners, or if you prefer, a commercial biocide (follow their directions) or a dilute bleach cleaning solution.
But because so many readers have asked about specific mold "cleaning" or mold "killing" methods we list and comment on these approaches below.
At MOLD CLEANERS - WHAT TO USE we provide a detailed description of different methods people use to "clean off" or "kill" mold.
Bleaching or "killing" mold is not the objective.
Bleach will not kill all of the mold anyway - we can tease viable spores out of lots of "bleached mold" samples we see in the lab.
The object of mold removal is to clean the surface, to remove loose moldy material, not to try to sterilize the surface.
Certain mold-contaminated materials that cannot be cleaned (drywall, carpeting, curtains) should be discarded. Clothing and bedding linens or towels can be washed or dry-cleaned.
Keep that in mind. If you want to use bleach as a cleaning agent instead of other cleaners (soap and water would work just fine) here are some mold cleanup suggestions for homeowners from the Canadian Mortgage and Housing Corporation CMHC.
See MOLD CLEANUP with BLEACH for details of how to mix and use bleach to clean a hard surface in a building as well as warnings about where bleaching mold is a cosmetic band-aid that just won't work. Here are the basics of using bleach to clean up a building surface:
CAR SMELL - Mold DEODORIZING - mold in cars, campers, trucks, RVs can be caused by water leaks and can make a moldy smell problem that's hard to cure.
Renters may also want to
see RENTERS & TENANTS GUIDE TO MOLD & INDOOR HAZARDS.
Home inspectors should
see MOLD TEST by HOME INSPECTORS?
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
@Natasha,
Sorry I really can't make out what's in your photo besides the white plastic piping. If there is gypsum board or drywall that is moldy then it needs to be completely removed.
In general, it's not necessary to identify the genera/species of mold in buildings before removing it: knowing the mold genera/species does not change what's needed one bit:
remove the mold
clean the exposed surfaces
fix its cause
If that's moldy drywall or gypsum board in your photo, it needs to be removed. Surface cleaning or spraying alone are not effective.
Also, that plastic drain looks improper and likely to leak - not to mention that it seems to be connected using plastic electrical tape.
On 2022-10-19 by Natasha
Is this and what kind of mould is this
On 2022-06-20 by InspectApedia-911 (mod) - multiple colors of mold indicate need for remediation
@Logan,
When you see that much mold growing on into a surfaces there's no doubt that there is harmful mold present.
It's a fundamental mistake to think that the only mold you care about is black in color. There are at least two hundred common mold genera / species that commonly grow in buildings, only a few of which are quite dark in color.
Fortunately knowing the mold genera and species doesn't change what's needed at all.
For the situation in your photo professional remediation is what's required.
That means remove the molding materials, clean the exposed surfaces, and find and fix leaks or moisture that caused the mold growth.
Take a look at the Mold Cleanup Guide above on this page.
On 2022-05-18 by Logan
What type of mold is this? Is it toxic black mold?
This Q&A were posted originally at
...
Continue reading at CARPET MOLD / ODOR TESTS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see MOLD CLEANUP GUIDE - HOW TO GET RID OF MOLD FAQs - questions & answers posted originally at this page.
Or see these
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about the best procedures to get rid of mold and mold smells in buildings
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.