Water Pump Control Switch Debris Clogging
Sediment or debris or rust in the water supply can clog the sensor tube or pressure control switch sensor port that in turn means that a water pump may not turn on or off properly in response to water pressure.
Here are questions & answers on how to diagnose, find and fix the problem.
This article series explains how to diagnose & repair water pump intermittent cycling - the water pump comes on when no water is being run in the building. Intermittent water pump cycling means that the water pump comes on for no apparent reason.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
These questions & answers about problems with a pump pressure control that doesn't respond properly to water pressure were posted originally at at WATER PUMP CONTROLS & SWITCHES - so be sure to see the diagnosis and repair articles starting there.
Also see our index to all water or well pump control switch questions at WATER PUMP PRESSURE SWITCH REPAIR FAQs
...
For the past six months or so my water well pressure gauge has not worked. I replaced it yesterday and the cut-out occurred at over 100lbs - should be around 50 or so.
My first thought was the problem is with the new gauge, but i cycled the pump on again and noticed that the pump ran longer than normal before cutting-off at over 100lbs.
The gauge numbers stop at 100 and based on the alignment of the numbers, the cut-out is around 150lbs. - WOW. Is that even possible. I have a three horse pump and the pipes coming from the manifold are galvanized.
The pressure switch is original (2001) and have cleaned the contacts on several past occasions. On 2018-06-11 by Jim
by (mod) - a clogged water pressure switch can be dangerous: overpuressure, bcurst water tank!
Jim
Watch out: turn the pump off immediately and Rain pressure from the system. So it's high pressures are dangerous. A pipe or water pressure tank can burst causing not only a flood but an injury to someone who is nearby.
Probably the same problem that cause your pressure gauge not to work Has filed the pressure control switch. Often debris or silt in the water supply clogs the sensor port on the pressure gauge and similarly clogs the pressure sensor opening on the bottom of the pressure control switch. You need to replace the switch and make sure that any tubing or small diameter pipe that conducts water pressure to the switch is not blocked.
...
I have no water at all . 0 pressure at tank and pump doesn’t come on at all even with new pressure control switch. The well is around 13 years of age. Why is it collecting this and do you think my pump is ruined? How can I prevent this in the future?
On 2021-05-04 by Douglas Grooms
And from another reader:
Our water pressure switch doesn't seem to kick in when it should causing low water pressure. How can I fix that? On 2018-06-04 by Dave Johnson
Answer by danjoefriedman (mod) Notice all that reddish brown gunk: looks like rust or mud debris that is clogging your water pressure control switch sensor port
@Douglas Grooms and Dave Johnson:
A common cause of the problem you described is a pressure switch that is debris clogged and not sensing a change in water pressure. The Simple Solution is to replace the switch.
On this page in my answer below you'll see that rust, mud, or other debris clogging the pressure sensor port on your pressure switch or the tube that conducts water pressure to the switch can cause the pump to not turn on or off as water pressure drops or increases.
...
Just replaced a 30/50 switch because the 1 hp jet pump could not get above 37 and would not turn off. The pump, tank and pipe with foot valve are 1 year old. No problems until a few days ago, would not shut off. I was manually turning the pump on and off at the breaker. I am a senior lady living alone.
When I smacked the switch it would turn off however. Then the next day, it made it to 50 and turned off by itself. Yay! Fixed? No, a few hours later stuck at 37. My ex installed a new switch yesterday.
Adjusted the tank by a couple pounds (to 28) and it came on at 30 and off at 50. Only once though.
Now it is back to 30/37. No leaks, pressure stable unless using water. Ex wants to install a 20/40 switch. I don’t understand what this could be?
One day it pumps up to 50 and then only 37 with no stopping. This new switch doesn’t turn off when I try and flip the contacts either. I have to use the breaker to turn it off. Help! On 2020-11-02 by Kathy
Explanation by (mod) - debris clogging or bad relay
Kathy,
Usually when a pump will not turn off and cannot reach the cut-off pressure set on the pressure control switch the problem is not the switch but rather that the pump and water supply are not able to deliver that pressure. That's particularly true if you're cut off pressure is at a normal level of a say 40 or 50 psi.Your comment "When I smacked the switch it would turn off however." suggests that the pressure control could be debris clogged. You should have that control replaced.
I am only able to speculate as I'm not on the scene possible that you are what are you straight exceeded the wills flow rate so the pump in fact simply couldn't get enough water to send into the pressure tank to reach the cut-off pressure. When you then leave the pump off for a time that gives your well a chance to recover and that in turn might allow the pump to operate normally.So why don't you do an experiment letting the pump system rest for several hours or longer when it's misbehaving.
Then turn it back on to reach a cut off pressure I suspect the problem is in your well and the well flow rate and it would just be a waste of ex's time and energy to change switch.
We have old farm house. Pressure tank been getting rusting. Few days ago, water nasty, pump running continuously. Put in new pressure tank and all piping around it. Water pressure good. Cleanliness seems to have increased.
Problem: pressure switch not cutting off...will adjust setting.
When turn off switch manually, tank pressure decreases immediatley, which would kick pump back on. Seems to be back filling. Have shut off valve between tank and well, when turn it, tank holds pressure.
Something wrong with well? How would I check to see if foot or check valve is bad and what do I do? water nasty, pump running continuously. - On by Sam
Reply by (mod) List of Repair Procedures for Various Water or Well Pump Problems
I agree that debris or sediment in the water supply can cause a pump pressure control switch to fail to respond to water pressure: clogs in the sensing tube or in the tiny opening of the sensor diaphraghm on the bottom of the pressure controls switch can prevent the switch from "feeling" increases or decreases in water pressure.
So that could cause a pump fail to turn on or off when it should.
But the fact that y our water pressure drops immediately when you turn off the pump might indicate that there's aleak somewhere in the well piping or check valve or at a foot valve - a second problem.
I would start by changing the pump pressure switch and replacing the foot valve or other check valve if one is at your pump or elsewhere in the well piping. Here's a summary of well problems and cures that may help you sort this out.
...
I have a problem I lose water pressure to my house and I go and check the well and the pump is not running. I have a submerge pump and there is switch at well for pump and turn it on and off and then it comes on and I have pressure and water.
When my Blue Pressure tank is empty then I lose pressure and the pump does not come on.
So I turn it off and on and it comes on and stays on. Not sure if it always stayed on and did this or if this a new problem. Then when I get water pressure and water and the blue pressure tank is empty it starts all over again.
Is this a pressure switch problem? Also I get lots of air coming when I do have water pressure. I check the air pressure in my Blue Pressure tank and it is good.
Thank you in advance. On 2017-12-31 by Jim Norman
Suggestions by (mod) -
WHEN the pressure drops below the cut-in
AND the pump control switch doesn't turn on the pump,
AND IF there is electrical power to the pump
THEN the control's pressure sensor port may be debris-blocked.
First try cleaning the tube conducting water pressure to the pump. If that doesn't work then debris may have also clogged the pressure sensor port on the bottom of the pressure control switch. In that case, easiest is to simply replace the switch.
Why would the pressure switch work normal and then at times you have to tap on switch to make contact On 2017-12-14 by Rick
Suggestions by (mod) -
Great question, Rick.
There are two common explanations for a finicky pressure control switch that lies there like my sleeping dog Katie until tapped to wake up.
1. dirt or debris in the pressure switch water pressure sensing port is clogging the switch, or dirt / debris in the small pipe nipple or tube that conducts water (and pressure) to the bottom of the switch is clogged: either of those blockages can be prevent the pressure control from registering a water pressure drop that should turn on the pump
2. An internal electrical problem in the switch such as a loose wire or burned contact points.
Watch out: don't go poking the wires in the switch nor trying to tighten wiring connections with power on - you could be shocked and killed.
At times when I am in the shower, I need to get out flush the toilet to get the water back to the shower, or stand there for 1 min and wait...any suggestions (Mar 6, 2014) Roy
Reply:
Roy, this situation sounds odd but I can guess at a possible explanation: if your water pump pressure control switch is sticking - not responding properly to pressure drop, the pressure may have to fall still further below the cut-in level before the pump switches "on".
This often happens if there is silt or debris in the water - conditions that can clog the small diameter pipe on which the pressure switch mounts, or the small orifice at the switch bottom through which water exerts its pressure.
Try replacing the pressure switch and its mounting tube.
...
Saw where they kept thinking it was the switch gone bad only to find out it was from a clogged filter. Where is the filter?
We have an Artesian Well and GeoThermal heating and cooling. Right now cooling. The NEW switch we put in is getting stuck on zero again. On 2018-05-08 by Juju
Thanks for the comment Juju.
Indeed I've run into clogged water filters too - a symptom of a clogged water filter right at the water pump / pressure tank is very rapid on-off cycling of the pump and pressure control switch.
Similarly, debris-clogged faucet strainers and shower heads can fool us. That's why those are among the first places to look when water flow is weak.
Keep in mind that many building water supply systems, probably most, have no filter installed whatsoever.
Only where silt, mud, or debris is common in the water supply will we usually find a sediment filter; other reasons for filters are water odors.
See details at https://inspectapedia.com/water/Water_Filters.php
If your new pressure switch is sticking check that there is no clogging of the small diameter pipe or tube that conducts water pressure to the switch sensor port.
See also WATER PUMP PRESSURE CONTROL where we discuss clogging of the pressure sensor tube that communicates pressure in the water pump and tank over to the pump pressure control switch.
...
...
Continue reading at PRESSURE CONTROL SWITCH DEBRIS CLOGGING - topic home, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
WATER PUMP CONTROL SWITCH DEBRIS CLOGGING FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.