Sources of Running Water Noise in/at Buildings
This article describes all of the known sources of running water noises in or around buildings and suggests some diagnostic steps that can help pinpoint the noise source and thus indicate what repair is needed.
Page top photo: running water noises may be coming from water lines coming to the building or from pipes inside the building, both water supply pipes and drain lines.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
Find and Fix Sound of Running Water in Buildings
This article describes the probable causes of noise that sounds like water running in water supply pipes or in building drain pipes.
Article Index
Photo: those ceiling stains tell us that there are plumbing leaks at fixtures above this point. But also, any dripping or running water into these exposed plastic drain lines may be heard and may annoy or alert building occupants to a plumbing problem that needs repair.
...
List of Sources of Running Water Noises
A sound of running water as discussed here may also be described by some folks gurgling noises in pipes.
Quick Summary of Running Water Noise Sources
- Running water in plumbing system drain piping system
when plumbing fixtures are in use ( a sink is running or a toilet was flushed) and will be more noticeable if the building drain piping is not sound-isolated or insulated and where plastic rather than cast iron drains are installed.
Running water in drains when no fixture is known to be running is likely to be traced to a running toilet or less often, to a roof drainage system routed through the building's interior or actually into its drain piping.
- Running water in building water supply piping
might be heard when fixtures are in use, again more-so when piping is not run through a sound-isolating system of mounts and / or insulation.
- Running water or gurgling sounds traced to refrigerant piping
may be in refrigerant or condensate piping of a split system air conditioner or heat pump while the equipment is running and/or briefly during unit start-up as well as for a period immediately after the unit shuts off.
While usually we consider the sight or sound of bubbles in the refrigerant piping as an indication of low refrigerant, for some systems this may not be the case and for at least some split system models Fujitsu points out that this sound may be normal.[10]
However if you hear bubbling in the refrigerant piping and the system is not cooling properly, indeed there may be an improper charge or refrigerant may be leaking.
See REFRIGERANT LEAK REPAIR
- Running or bubbling water sounds are heard in hot water heating system pipes, baseboards, radiators, & fan convectors if there is excess air in the heating system piping.
See AIR-BOUND HEATING SYSTEMS
And check out BOILER LEAKS CORROSION STAINS for leaks in or at the boiler or see CIRCULATOR PUMP LEAKS
Also for heating equipment that uses an oil burner,
see OIL BURNER PIPING GURGLING
- Running or gurgling at a building water tank
may be normal during tank re-fill or there may be problem, as we discuss
at WATER TANK BUBBLING / GURGLING NOISE DIAGNOSIS
Complete List of Running Water Sound Sources
Common sources of running water noises in a building when you think that no water is being used are listed below.
- Air conditioner or heat pump refrigerant:
An air conditioning or heat pump system might make bubbling running noise in its refrigerant piping if the refrigerant charge is low - perhaps there's a refrigerant leak or an improper, too-low refrigerant charge in the system.
See REFRIGERANT PIPING NOISE - running water or gurgling sounds, sounds in refrigerant piping - floodback or condensate
And remember to look for running water noise traced to the disposal of air conditioning or heat pump condensate -
see CONDENSATE PUMPS and CONDENSATE DRAIN CLEAN & DE-CLOG
- Check valve leaks:
Leaky check valves at a private pump and well system can cause the water pump to cycle on and off intermittently.
In turn, that might produce running water sounds in building water pipes near the pump or there could be noise transmission through building water pipes to other building areas.
See FOOT VALVES, WELL PIPING - check valve in the well including FOOT VALVE LEAK TROUBLESHfING
See INTERMITTENT CYCLING WATER PUMPS.
- Drain pipe clogs or leaks:
A drain can be partly clogged, accumulating wastewater that slowly drains past the obstruction, making running water noises in a drain.
See CLOGGED DRAIN DIAGNOSIS & REPAIR.
See GURGLING DRAINS
Also see LEAK TYPES, WATER SUPPLY or DRAIN PIPES
- Hot water heating system:
Leaks in heating
zone pipes, radiators, etc. can, if there's air in the system, make a running water noise or slow leaks may make a dripping noise.
See AIR-BOUND HEATING SYSTEMS
Also
see OIL BURNER PIPING GURGLING
- Outdoor irrigation systems or watering systems or swimming pool
All of these sorts of
water movement systems that you might not notice during daytime may be more obvious at night
- Plumbing Fixture Leaks:
A leaky faucet may drip into the fixture (sink or tub) that in turn causes noises in the building plumbing drain system.
See
- Plumbing vent pipes:
A defective plumbing vent can cause slow gurgling at fixture drains when water is sent into the drain, but it would not itself directly be releasing water unless it's a wet-vent that is serving as both drain and vent OR if condensation froze in the upper portion of the vent (where the vent passes through the roof infreezing weather) when warm weather arrives and that ice melts you might hear a dripping noise in the vent or drain piping.
See PLUMBING VENT NOISE
- Roof drains or water from rooftop equipment
Clogs or leaks in a flat or low-slope roof drain system may cause running water or dripping water noises in buildings at which the roof drains run down through the building interior or perhaps through a vertical drain whose noises are transmitted inside such as where a drain passes near a window or door.
See FLAT ROOF DRAINAGE SYSTEMS
Water draining from rooftop equipment such as an air conditioner or heat pump whose condensate may be piped through or near the building may produce running water noises heard in building drains.
- Toilet running:
Atoilet may have a fill valve that is not shutting off completely; when this happens the toilet tank or cistern may fill until it begins to drain into the tank overflow, down into the toilet bowl. YOu may hear water running into the toilet or elsewhere in the building you may hear water running into a drain.
If the problem is only the toilet fill valve, noise of water entering the toilet tank or cistern may be continuous while the drain noise may be either continuous or intermittent.
If the problem is a leak at the toilet flush valve, the drain noise
may be continuous while the noise of water entering the toilet flush tank will be intermittent as the toilet flush valve float periodically drops low enough to open the tank fill valve.
- see TOILET RUNS CONTINUOUSLY
- Water supply line leak:
A water leak can be hidden - in a wall or crawl area, even under a slab or outside the building at a water main or a buried line to a hose bibb.
Leaks in either municipal water supply lines or private pump, tank and well systems can cause running water noise heard in or near a building.
For municipal water supply line leak diagnosis see MUNICIPAL WATER PRESSURE DIAGNOSIS
For private water pump, tank and well system leak diagnosis see WELL PIPING LEAK DIAGNOSIS
and WATER PUMP SHORT CYCLING - PIPE LEAK
Also see LEAK TYPES, WATER SUPPLY or DRAIN PIPES
- Water tank running water noises
see WATER TANK BUBBLING / GURGLING NOISE DIAGNOSIS
- Water treatment equipment:
A water softener or other water treatment equipment that's running through a regeneration cycle - usually timed to operate late at night when other water use has stopped.
- Well piping leaks
A leak in well piping isn't usually heard as running water in the building but might if it causes an above-ground in-building well pump to cycle intermittently
See WELL PIPING LEAK DIAGNOSIS
...
Diagnostic steps help isolate the source of running water noise
If you are hearing running water in a building and it's cause is somewhere in the plumbing system, that is, not if it's not a similar noise from a hot water or steam heating system nor from an air conditioner or heat pump system and pipes, then the source is a water supply system leak.
A plumbing leak in the building water supply pipes or controls can cause water to run either constantly or intermittently. The leak may:
- occur only when a fixture is in use, when a valve such as a faucet is open - drips at the faucet control may be visible into the fixture or hidden in a wall, ceiling or floor cavityu.
- occur constantly, if the leak is in supply pipes or connections anywhere in the system
Try turning off water supply to individual plumbed areas or fixtures - even turning off things that you are dead sure are not involved, just be sure you're not missing something.
Or you can turn everything off at once and listen for a cessation in noise (include allowing for a backed drain to empty) but a slower alternative that's more convenient is to turn off by area or fixture.
Also look around for wet areas and leak stains such as in basement ceilings and in crawl areas.
See PLUMBING LEAK DETECTION METHODS
Also see DRIPPING WATER SOUND SOURCES and
see SOUNDS of RUNNING / DRIPPING WATER in DRAINS
...
ADVERTISEMENT
...
Continue reading at PLUMBING DRAIN NOISE DIAGNOSIS, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
RUNNING WATER NOISE in BUILDINGS: CAUSE & CURE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & References
In addition to any citations in the article above, a full list is available on request.
ADVERTISEMENT