Weil McLain Heating Equipment Manuals, Parts, Wiring Diagrams
Manuals, parts lists, wiring diagrams for Weil McLain Boilers & heating equipment:
Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturers who can provide that information for nearly all major brands of HVAC equipment.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Article Contents...
Contact: Weil McLain Corporation Weil-McLain Headquarters 500 Blaine Street Michigan City, Indiana 46360
USA Tel: 219-879-6561 Fax: 219-877-0556 Website: https://www.weil-mclain.com
Weil-McLain Administrative Office, 999 McClintock Drive, Suite 200, Burr Ridge, IL 60527
Tel: 855-248-1777
Consumer Inquiries: 800-368-2492
Technical Services: 800-526-6636 Technical Support for Contractors Only.
If you are a homeowner and are experiencing a problem with your Weil-McLain equipment, the first step you must take is to contact your installer or locate an HVAC contractor in your area.
Website: http://www.weil-mclain.com
...
Weil McLain Corporation - Discontinued furnaces and boilers and parts lists are documented at this link: http://www.weil-mclain.com/en/our-products/discontinued-boilers.aspx including the following equipment:
Discontinued Weil McLain Boilers , Gas Boilers, 66 Boiler 68 Boiler, P66HE/B66HE/A66HE Series 3 Boiler Manual 68/68V Boiler Manual, Parts List Parts List , 78 Boiler 86 Boiler 88 Series 1 Boiler AHE Boiler, Boiler Manual Erecting Manual Brochure Boiler Manual, Parts List Operating Manual Boiler Manual Altitude Conversion,
Parts List Silicone Sealant Addendum Information Manual, Specifications in pdf Parts List, Parts List Wiring Diagrams, Series 3 - Fenwal 05-21 Ignition/Sensing Control System Series 2 - White-Rodgers Cycle Pilot Ignition/Sensing Control System, Series 3 - Fenwal 05-31 Ignition/Sensing Control System, CE/CER/PER Electric CG/CGM Boiler CGi Boiler, CE Boiler Manual CG Series 11 CGX Series 1 Manual CGi Series 1,
CER Boiler Manual CG Series 12 CGX Series 2 Manual, PER Boiler Manual CGM PCG Series 8 Manual, All Electric Parts List CGM PCG Series 9 Manual, Wiring Diagrams CGM Series 10 Manual, CE Series 2 - 208/60/1 or 240/60/1 Power Supply PCG CG Installation, CE Series 2 - 208/60/3 or 240/60/3 Power Supply PCG CG Operating, CER Series 2 - 208/60/1 or 240/60/1 Power Supply PCG CGM Series 6 Installation,
CER Series 2 - 208/60/3 or 240/60/3 Power Supply PCG CGM Series 7 Installation, PER Series 3 - 208/60/1 or 240/60/1 Power Supply Startup Service Maintenance, All CG Parts List, D Boiler EG/PEG/EGH PFG Series 6, D Gas Series 2 Erect EG PEG Series 1 EGH Series 2 Boiler Manual PFG Series 6 Brochure, D Gas Series 2 Erect EG PEG EGH Series 3 Manual PFG Series 6 Boiler Manual, PD Gas Series 3 Install EG Parts List PFG Series 6 Specs in pdf, EGH Parts List,
GO Series 1 & 2 GV Boiler Ultra Series 2, WGO Series 1 Boiler Manual Series 1 Boiler Manual Boiler Manual, WGO WTGO SGOW Maintenance And Service Guide Series 1 Control Suppliment Specifications in pdf, WGO WTGO SGOW Series 2 Maintenance And Service Guide Series 2 Boiler Manual Antifreeze Supplement, WTGO Series 2 Installation Series 1 & 2 Users Manual User's Manual ,
Gv Series 1 & 2 Parts List, Series 3 Boiler Manual Vent Supplement, Series 3 Users Manual Vent Supplement , Series 3 Condensate Line Concentric Vent Supplement, Series 3 Direct Vent Control Supplement, Series 3 FasNSeal Control Addendum Interface Kit, Series 3 Safe T Vent 3" Wall Mounting, Series 3 Safe T Vent 4" Multiple Boiler Systems (MBS) , Series 3 StaR 34 MBS Alarm Module Instructions, Series 3 ZVent II Remote AM4 Modulation Control ,
GV Series 3 Parts List Natural to Propane Gas Conversion, Altitude Conversion - Over 5500 feet, Gasket Replacement - Series 1 & 2, Technical Literature , Freeze Protection, G Boiler H Boiler HE Boiler, Operating Manual Series 4 Erecting HE Series 2 Brochure, HE Series 2 Boiler Manual , HE Series 3 Brochure , HE Series 3 Boiler Manual , HE VHE Homeowner Info, HE VHE Users Manual, HE VHE Series 2 Natural Gas, HE VHE Series 3 HSI,
HE VHE Series 3 HSI Supplement , HE VHE Series 3 Natural Gas, HE VHE WR Series 2 Propane, HE VHE WR Series 3 Propane, VHE Series 3 Manual, Parts List, HE II Boiler MGB Boiler P-35 Boiler, Boiler Manual MGB Erecting P-35 Steam Installation, User's Manual Parts List, HSI Gas Control Supplement, Parts List,
...
If the CP# is only 6 digits, enter a leading zero, e.g. 0137718. This look-up will not give manufacturing information for any other Weil-McLain product but boilers,
Currently, no information is available for EG and EGH boilers. For those models you'll need to call the manufacturer.
WeilMcLain provides an online age decoder for their boilers: https://www.weil-mclain.com/cp-lookup will decode the heating boiler's CP/Serial Number. At the company's website you will find these instructions:
Enter the 7-digit CP/Serial Number of the boiler to obtain the manufacturing date and any associated information on the product.
If the CP# is only 6 digits, enter a leading zero, e.g. 0137718. This look-up will not give manufacturing information for any other Weil-McLain product but boilers. Currently, no information is available for EG and EGH boilers.
...
Condensate in pressure switch line locks out my Weil McLain GV4 BoilerI am getting a few drops of condensate in the line to the pressure switch on my GV4 Weil McLain boiler.
It is enough that the flow switch will not satisfy for a successful start.
Drain the hose and it is okay for several starts.
After several cycles condensed appears again and locks out the system. Air flow is clean and dry. Could burner assembly need cleaning or replaced? - On 2019-02-12 by Tom
by (mod) - Weil McLain GV4 Boiler Condensate Troubleshooting & Safety Warnings
Apologies Tom an authoritative reply is beyond my expertise. With that caveat I will offer a few comments:
First: Watch out: see this Weil McLain Boiler CO Leak Hazard & RECALL Information - check your gas valve to see if this important safety recall pertains to you.
Otherwise: I I'd check first to be sure that condensate is being properly routed and the drain is not clogged, kinked, improperly-sloped. I'd look for clots of dust getting into the line, which might indeed point back to a need for cleaning /service.
Specific and key to the Weil McLain gV4 boiler is a bypass circulator that you want checked. If you don't have the manual for your boiler you can obtain one from WeilMcLain at www.weil-mclain.com/sites/default/files/field-file/gv-series-4-manual_1.pdf
or at WEIL McLAIN GV4 BOILER MANUAL [PDF]
Here is an excerpt:Bypass circulator
The GCM operates the bypass circulator to mix hot water from the boiler outlet with colder return water from the system as needed to prevent condensation of flue gases in the boiler.
When the water returning to the boiler is below 140 °F, the GCM regulates the bypass circulator and system circulator flow rates to raise the return water temperature up to 140 °F before it enters the boiler sections.
By balancing these flow rates, the GCM can protect against condensation even if return water is as low as 60 °F. Pump must remain on boiler — do not remove.
Watch out: there are a lot of other detail about venting the GV4 and about proper handling of condensate including a whole section beginning on p. 12 in the manual.
A mistake coiuld make the boiler unsafe and even risk fatal carbon monoxide poisoning.
Vent systemWatch out: The GV boiler requires a special vent system, designed for pressurized venting with likelihood of condensation in the vent.
This is referred to as ANSI Z21 Class IV, Condensing. You may use any of the vent systems covered by the GV venting supplements included in the instruction manual envelope.
The GV vent starter tee is a special item designed only for the GV boiler, available from each vendor.
Do not attempt to connect the vent to the GV boiler with any other means. DO NOT mix components from different systems.
The vent system could fail, causing leakage of flue products into the living space, causing severe personal injury or death.
The company states
This manual must only be used by a qualified heating installer/ service technician. Failure to comply could result in severe personal injury, death or substantial property damage.
Watch out: see this Weil McLain Boiler CO Leak Hazard & RECALL Information
Non-Condensing Weil McLain GV4 series 2 is condensing all the time.
No matter what the return water temperature is. Sometimes you can see water vapor come from the condensate drain along with the dripping water.
Can you please shed a little information as to what's causing this? (Jan 15, 2016) Alan said:
Reply:
Improper combustion air adjustment or inadequate combustion air can cause condensation as can a boiler leak.
Watch out: inadequate combustion air supply produces not just water but fatal carbon monoxide - see COMBUSTION AIR REQUIREMENTS
And also
Watch out: see this Weil McLain Boiler CO Leak Hazard & RECALL
...
Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
WEIL McLAIN MANUALS, AGE, CONTACT at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.