In this index you will find links to the manual for your oil burner used on heating equipment.
This article series answers most questions about central heating and water heating systems and provides guides for troubleshooting, inspection, diagnosis, and repairs.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
Oil Burner Manuals & Guides for Boilers, Furnaces, Water Heaters
AUDELS OIL BURNER GUIDE, INSTALLING, SERVICING, REPAIRING, [PDF complete online copy of this book] Frank D. Graham, Theo. Audel & Co., New York 1946, 1947, 1955 (out of print, copies occasionally available from antique book dealers and on EBay).
Use THIS LINK to read a free online copy [web page] of this helpful classic textbook.
Updated versions of this guide are available in various editions, 1947, 1950, 1955, 1958, 1959, 1962, 1965, 1967, and at prices from around $3.00 to nearly $70.00 - useful for simple, clear, but not current, explanation of how heating equipment works. The original retail price was $1.00. Used copies are available
AUDELS OIL BURNER GUIDE (excerpt) [PDF] (1960) courtesy of heatinghelp.com (complete hard copy available at InspectApedia)
The ABC's of Retention Head Oil Burners, National Association of Oil Heat Service Managers, TM 115, National Old Timers' Association of the Energy Industry, PO Box 168, Mineola, NY 11501. (Excellent tips on spotting problems on oil-fired heating equipment. Booklet.)
US DOC, AUTOMATIC MECHANICAL-DRAFT OIL BURNERS DESIGNED FOR DOMESTIC INSTALLATIONS [PDF] (1942) U.S. Department of Commerc & U.S. National Bureau of Standards
Excerpts: Purpose:
The purpose of this commercial standard is to establish minimum standard specifications and methods of test for automatic mechanical draft oil burners for the guidance of manufacturers, distributors, installing contractors, and
users.
Scope:
This standard covers
(a) General requirements
(b) Manufacturing and production tests
(c) Laboratory requirements and test procedure
(d) Installation requiremenbts and performance tests
(3) Oil burner certificate placed with each burner installation
Beckett Cleancut Installation Information, Single Stage Fuel Unit PN 21844 & 2-Stage Fuel Unit PN 21941", (2007) R.W. Beckett Corporation, website: http://www.beckettcorp.com, 38251 Center Ridge Rd.
North Ridgeville, OH 44039,
Phone:
440-327-1060,
Fax:
440-327-1064,
Email:
sales@beckettcorp.com
Beckett Corporation, 38251 Center Ridge Rd.,
North Ridgeville, OH 44039 440-327-1060 Email: sales@beckettcorp.com supplies residential and commercial oil burners for boilers, furnaces, and water heaters - see www.beckettcorp.com/
See our complete list of Beckett Oil Burner Controls & Control Manuals found under "Beckett" at
Excerpt: The Beckett GeniSysTM Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications having firing rates less than 20 GPH.
The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can also provide interrupted or intermittent duty ignition.
Excerpt: The Beckett HeatManager is a patented microprocessor-controlled fuel-saving device for residential hot-water (boiler) heating systems.
The HeatManager reduces fuel consumption, wear on boiler parts and burner emissions by actively managing the burner, in conjunction with the aquastat, to properly match the boiler output to the required load.
Beckett Corporation, OIL BURNER START-UP RUMBLES [PDF] Beckett Corporation, retrieved 2021/12/06 original source: https://www.beckettcorp.com/support/tech-bulletins/solving-rumbles-and-pulsations/
Excerpt: Combustion noise can occur in three major areas: at start-up, during the run cycle, and at shutdown. The following information is provided to help you effectively troubleshoot these areas.
C
Carlin Combustion Technology, Inc., 126 Bailey Road, North Haven, CT 06473 USA Phone: (203) 680-9401 Email: info@carlincombustion.com; Carlin produces oil burners, gas burners, and related HVAC controls.
Field Controls, COMBUSTION AIR SYSTEM CAS-2WM MANUAL [PDF](2009) Weil McLain Outside Air Kit for Oil Burner Models QB180 & QB300, Field Controls, LLC., Tel: 252-522-3031, Website: www.fieldcontrols.com, retrieved 2018/03/14, original source: https://www.torrco.com/ASSETS/DOCUMENTS/CMS/EN/IAH-4-overview.pdf
Gordon Piatt Oil Burners: Gordon Piatt oil burners are commercial equipment produced for half a century; the company is no longer in operation but its burners remain in service
GORDON PIATT OIL BURNER Models R & S INSTRUCTION MANUAL [PDF] Gas and pressure atomizing light oil fuel systems Manufactured by John Zink company, LLC retrieved 2020/01/15 original source: http://www.gordonpiatt.com/manuals/Gordon-Piatt-RS-Burner-Manual.pdf
GORDON PIATT OIL BURNER Model F INSTRUCTION MANUAL [PDF]Gas and pressure atomizing light and heavy oil fuel systems Manufactured by John Zink company, LLC retrieved 2020/01/15 original source: http://www.gordonpiatt.com/manuals/Gordon-Piatt-F-Burner-Manual.pdf
Contact: Gordon-Piatt® oil burner parts from OEM Boiler Parts, a division of Burton Mechanical Ltd. / OEM Boiler Parts
25 S. Cherry Alley
Elizabethtown, PA 17022 USA Tel: (717) 367-9900 Email:
sales@gordonpiatt.com Website: http://www.gordonpiatt.com/
Parts and supplies are available from various vendors including
PC McKenzie in Pittsburgh, PA, TOLL FREE 1-877-244-4883
E-Mail: parts@mckenziecorp.com Phone: 1-412-257-8866 Website: http://mckenziecorp.com/ who provide service manuals and parts explosion drawings
HAUCK MRO OIL-AIR REGULATOR INSTRUCTIONS [PDF] Hauck Manufacturing Co., P.O. Box 90 Lebanon, PA 17042-0090 USA Tel: 717-272-3051 Website: www.hauckburner.com, retrieved 2018/03/14, original source https://docuthek.kromschroeder.com/documents/download.php?lang=de&doc=18210
I
Iron Fireman boilers & oil burners, parts, manuals (commercial). The Iron Fireman boiler and burner company ceased operations in 2011, but parts and records are currently held by the OEM Boiler Parts Co. cited just below.
Contact: Iron Fireman® oil burner parts from OEM Boiler Parts, a division of Burton Mechanical Ltd. / OEM Boiler Parts
25 S. Cherry Alley
Elizabethtown, PA 17022 USA Tel: (717) 367-9900 Email:
sales@oemboilerparts.com Website: http://www.oemboilerparts.com/parts-iron-fireman.html
A history of the Iron Fireman boilers is given by OEM Boiler parts at the link just above
J
K
Kewanee Boilers & Oil Burners, parts & Manuals,
Contact: Kewanee® oil burner parts from OEM Boiler Parts, a division of Burton Mechanical Ltd. / OEM Boiler Parts
25 S. Cherry Alley
Elizabethtown, PA 17022 USA Tel: (717) 367-9900 Email:
sales@oemboilerparts.com Website: http://www.oemboilerparts.com/parts-kewanee-boilers.html
Website excerpt: OEM Boiler Parts owns the following assets, previously owned by Kewanee Boiler:
All engineering drawings known to exist, the oldest of which date back to 1916.
Engineering and sales records for each boiler produced by Kewanee after mid 1970. These records contain the bill of materials for each boiler, as-built.
Purchasing records for all Kewanee purchases from 1985, so that we can identify, procure, and provide the exact part which was installed on your Kewanee boiler as built from the factory.
North American Fire-All OIL BURNERS [PDF] Fives North American Combustion, Inc.
4455 East 71st Street - Cleveland, OH 44105 - USA
Tel: +1 216 271 6000 - Fax: +1 216 373 4237
Email: fna.sales@fi vesgroup.com
NU_WAY OIL BURNER MANUAL [PDF], (1998) Series NOL autoPVmatic oil burners, Models NOL1, NOL2, NOL3, Nu-way Limited, PO Box 1, Vines Lane, Droitwich, Worchestershire, WR9 8NA, England UK, Tel: Droitwich 01905, Email: info@nu-way.co.uk, Website: nu-way-co.uk, retrieved 2018/03/14, original source: https://nu-way.co.uk/image/data/pdfs/NOL%201-2-3%20Handbook.pdf
Contact Nu-Way Enertech Group in the UK at Tel: +44 (0)1905 794 331 Email: info@nu-way.co.uk
Nu-Way provides installatin manuals for all of the company's burners including the Nu-Way ST-series oil and gas burners, Nu-Way M-series oil, gas and dual fuel burners, Nu-way N-series burners, Nu-way P-series, A-series, Boxer Series, C, CH, Cx series bvurners, and the rest of the company's products at https://nu-way.co.uk/technical/technical-documents/installation-manuals
Nu-Way wood stove and propane stove manuals contact that Nu-Way Stove Manufacturing Co. PO Box 257
Millersburg, MI 49759 USA 989-733-8792 http://nuwaystove.com - see http://nuwaystove.com/manuals/ and
Oil burner electrode specifications for NuWay (and virtually every other oil burner brand and model) are given by
Westwood HEATING PRODUCTS CATALOG [PDF] Westwood HEating Products 330 William Street • P.O. Box 610 • South River, NJ 08882 USA, www.westwoodproducts.com that includes oil burner electrode specifications for Nu-Way on p. E9
O
OEERE, OIL-FIRED BOILERS - CODE COMPLIANCE BRIEF [PDF] OFFICE of
ENERGY EFFICIENCY AND RENEWABLE ENERGY
Forrestal Building
1000 Independence Ave. SW
Washington DC 20585 - retrieved 2022/07/21, original source: https://basc.pnnl.gov/code-compliance/oil-fired-boilers-code-compliance-brief
PVI FIREPOWER B-SERIES OIL BURNER MANUAL [PDF], (1997), PVI, Watts, 3209 Galvez Avenue
Fort Worth, TX 76111-4509
Phone: 817-335-9531
Toll Free: 800-784-8326
Fax: 817-332-6742
For Service Requests Please Call 800-433-5654retrieved 2018/03/14, original source http://www.pvi.com/pdf%20files/Installation %20and%20Maintenance%20 Manuals/PV500-22.pdf,
PVI is a Watts brand. Also manufactures water heaters.
QR
RAYBURN HEATRANGER 440/460/4890/499KB OIL BURNER MANUAL [PDF] (2014) for use in GB and IE, AGA Rayburn, Station Road, Ketley, Telford, Shropshire TF1 5AQ, Tel: Rayburn stockist: 0845 762 6147, Republic of Ireland Sales: 1850 302 502, Northern Ireland Sales: 028 8772 2195
International Sales: +44 (0) 115 946 6106,
UK CUSTOMER SERVICE CENTRE:
Service:
Tel: 0800 083 0602 or 0333 003 3467 or email customerrelations@agarangemaster.co.uk Email: raywarranty@aga-web.co.uk, retrieved 2018/03/14, original source: http://www.rayburn-web.co.uk/Prodin/ United%20Kingdom%20and%20Ireland/ Rayburn/Rayburn%20440,460,480,499KB %20BF/Rayburn%20460-499KB%20s erv%2005-14%20EINS%20511642.pdf
REMKO OIL BURNER MANUAL [PDF], REMKO GmbH & Co. KG
Klima- und Wärmetechnik
D-32791 Lage • Im Seelenkamp 12
D-32777 Lage • PO Box 1827
Phone +49 (5232) 606 - 0
Fax +49 (5232) 606260
E-Mail: info@remko.de
Internet: www.remko.de https://www.remko.de/download/zubehoer/waerme/mobil/en/SLV11-88-2_GB-P07.pdfretrieved 2018/03/14, original source: https://www.remko.de/download/zubehoer/waerme/mobil/en/SLV11-88-2_GB-P07.pdf
Contact: Riello Oil Burners: Canada:
Riello Corporation of America
2166 Meadow Pine Blvd.
Mississauga, Ontario,
Canada, L5N6H6
Technical assistance phone number 1-800-474-2556
Contact: Riello Oil Burners: U.S.
35 Pond Park Road
Hingham, MA 02043
USA, Tel: 781-749-8292
Toll Free 800-992-7637
Fax 781-740-2069
Websites:
www.riellousa.com wwwriello-burners.com
Technical Support Hotline
1-800-4-RIELLO
1-800-474-3556 retrieved 2018/03/14, original source: http://serl.qc.ca/wp-content/uploads/2015/10/manuel40-F15.pdf
RIELLO LIGHT OIL BURNERS, ONE STAGE MANUAL [PDF] (2009) Models RDB-series including RDV1-1R-2R Types 501-502-503, retrieved 2018/03/14, original source: https://www.rielloburners.co.uk/images/content/downloads/RBD1-1R-2R_2902661-3.pdf
RIELLO 40 SERIES OIL BURNER MANUAL [PDF] Models 40F3 & F5, retrieved 2018/03/14, original source: https://www.pexuniverse .com/docs/pdf/ r-f3-f5-installation-instructions.pdf
NOTE:
The settings in this manual are for retrofit applications. If this burner is being installed on a packaged unit (burner comes with the boiler or furnace), then follow the settings on the OEM page, as settings may differ.Burner is set for a single line system.
Sid Harvey OIL BURNER TROUBLESHOOTING GUIDE 1966 (excerpt) [PDF] (1966) courtesy of heatinghelp.com (newer (1971) hard copy available at InspectApedia)
Suntec, "Installation Information for Suntec A-2000, A-7000 Single Stage and B-8000 two stage fuel units"Suntec Industries, 60 Aberdeen Drive, Glasgow KY 42141, 270-651-7116 (1725 rpm black label, 3450 rpm white labells.
This manual was assembled with the service person and technician in
mind. Our objective was to give procedures and guidelines for efficient
and successful fuel pump installation and service. Many technical
manuals contain the necessary information; finding it is the problem.
This manual is divided into four major sections:
Sales-- What models to use and how they are identified
Installation--How to install the model selected
Piping-- Good practice piping installations and how to cope with
non-recommended piping found in previous installations.
Service-- How to test and service new and existing installations.
We have addressed situations found in the field which are not good
practice, but since they have been in use, we must contend with them.
If you have problems which you cannot answer, please contact Suntec’s
field service department at 800-367-7116.
Suntec, SUNTEC TECHNICAL MANUAL [PDF] (2018) European edition: retrieved 2020/02/24 original source: http://www.suntec.fr/wp-content/uploads/2018/03/Technical-manual_GB_ed2018_web-1.pdf
Excerpt: This manual describes the operation and installation of SUNTEC low flow oil pumps.
Excerpt: This manual describes the operation and installation of SUNTEC low flow oil pumps.
Conversion tables (replacement of models from other pump manufacturers by
SUNTEC models), presentation of our Universal AUV pump and a Frequently
Asked Question section will give you answers to the questions you face about the
maintenance and troubleshooting of your installations.
Includes details of converting from Danfoss or Delta fuel units to Suntec
TRIANCO OIL BURNER MANUAL [PDF] UK Models HE 50/90 & 100/125, (2010) TR Engineering Ltd., Unit 7, NEwton Chambers Way, Thorncliffe Industrial Estate, CHapeltown, Sheffield S35 2PH, UK, Tel: 0114-257-2300, Website: www.trianco.co.uk, retrieved 2018/03/14, original source: https://trianco.co.uk/wp-content/uploads/2016/01/223532-Contractor-HE-50-90-100-125-Burner.pdf
UV
VIESSMANN VITOFLAME 100 OIL BURNER MANUAL [PDF] (2005),Viessmann Manufacturing Company (U.S.) Inc.
45 Access Road, Warwick, Rhode Island, 02886, USA Tel. (401) 732-0667, Fax (401) 732-0590 www.viessmann-us.com, mail@viessmann-us.com
Viessmann Manufacturing Company Inc.
750 McMurray Road Waterloo, Ontario, N2V 2G5, Canada Tel. (519) 885-6300, Fax (519) 885-0887 www.viessmann.ca, mail@viessmann.ca
retrieved 2018/03/14, original source: https://www.viessmann-us.com/ content/dam/vi-brands/CA/pdfs/ doc/vitoflame/vitoflame_100_ii.pdf/_jcr_content/ renditions/original.media_file.inline.file/file.pdf
W
Wayne Oil & Gas Burner Manuals
Contact: Wayne combustion Systems (a ScottFetzer company) 801 Glasgow Ave
Fort Wayne, IN 46803 USA,
Tel: 800.443.4625 Website: https://waynecombustion.com/
In the 1970s when the author [DF] serviced oil burners, Wayne MSR oil burners were very common in residential properties in the Northeastern U.S. and were in fact easy to work-on. Here is what we have on Wayne oil burners||
or for international customers, George Nikiforov, Inc., 200 Park Avenue South, Suite 920, New York, NY 10003-1503 USA Tel: 212.473.4555 Email: international@geonikinc.com
WAYNE MODEL FH OIL BURNER MANUAL [PDF] (2010) Wayne combustion Systems, 801 Glasgow Ave., Fort Wayne, IN 46803 USA. The Wayne FH oil burner can be fired at ranges from 4.00 to 13.00 GPH.
Excerpt: Since 1928, Wayne has supplied the Homeowners of the world with oil burners. You are obtaining a quality burner
unsurpassed inengineering design and product development, l will provide you with many years of efficient,roublefree operation, ifproperly installed and serviced: Please read this manual carefully.
Wayne warrants its burners specifically to those who have purchased it for resale, including your dealer. lf, in any
case, you have a problem with your burner, or its installation, you should contact your dealer for assistance.
Webb, "The Oil Safety Valve (Service)", Charles Bursey, Sr., Fuel Oil News, February 2006 (Still trying to get the full article - October 2008 - DF) Charles W. Bursey Sr. can be reached at F.W. Webb Co. www.fwwebb.com/
Westwood Products, WHY USE TIGERLOOP® in FUEL HEATING SYSTEMS [PDF], Westwood Products Inc.
330 William Street
South River, NJ 08882 USA Tel:
1-800-442-1630 Website:
www.westwoodproducts.com retrieved 2018/03/14, original source: http://www.westwoodproducts.com/images/tigerloop_is_reliability_us.pdf
Tigerloop: oil line de-aerator devices, Westwood Products Inc.,
330 William St.,
PO Box 610,
South River, NJ 08882-0610 - (732) 651-7700 Website: http://www.westwoodproducts.com/tigerloop.htm
Westwood HEATING PRODUCTS CATALOG [PDF] includes Oil burner electrode settings; Westwood Heating Products 330 William Street P.O. Box 610 • South River, NJ 08882 USA, www.westwoodproducts.com that includes oil burner electrode specifications for most oil burners
Excerpt: The Beckett GeniSysTM Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications having firing rates less than 20 GPH.
The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can also provide interrupted or intermittent duty ignition.
Excerpt: The R7795 Flame Safeguard Primary Control provides flameout protection plus automatic control of commercial and industrial gas and oil burners. Models provide intermittent pilot or interrupted pilot with delayed main valve.
Excerpt: The [Honeywell] RA890F Protectorelay™ is a nonprogramming, amplifying relay that provides solid state electronic flame safeguard protection for industrial and commercial gas, oil, or combination gas-oil burners.
ADVERTISEMENT
Reader Comments, Questions & Answers About The Article Above
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
On 2020-04-27
by (mod)
- What to do about abnormally high hot water heating boiler pressure
Rhonda
What to do about abnormally high hot water heating boiler pressure
Watch out: excessive boiler pressure in a residential hot water heating system is dangerous, risking a BLEVE explosion (search InspectApedia.com for BLEVE for more details).
If your heating boiler pressure really is over 30 PSI and your relief valve is not opening, then the heating system is unsafe.
We need more information: you need to be more clear with me about what pressure or "psi" we're actually discussing.
Where are you reading "high psi" ?
If your boiler pressure were really over 30 psi, I don't think it would have been possible to replace a relief valve and an expansion tank without water pouring out at the connections for those devices. That would have relieved the pressure.
So if pressure was relieved in the hot water (hydronic) heating system boiler, piping, etc., and pressure is abnormally high again, either there is a water feed valve that is improperly adjusted or your gauge is simply stuck at an inaccurate pressure.
So, what is "High" and where and how are you determining that?
For details see
PRESSURE & TEMPERATURE SETTINGS, CONTROLS for boilers - at https://inspectapedia.com/heat/Heating-Temp-Pressure-Settings.php
My Beckett boiler psi stuck on high, replaced relief valve, expansion tank, how do I release the psi pressure, furnace does not fire up
On 2019-11-23 - by (mod) -
It would help me research to try to find manuals for your heater if you would post a photo of the heater and in additional comments photos of any logos or data tags you can find on the equipment
On 2019-11-22
by William Fillinger
I'm looking for a universal constant level flow control system for my seigler oil stove. A repair manual would be good. I can't find part numbers. Thanks
On 2019-10-12 - by (mod) -
John see the diagnostics in
OIL BURNER WONT RUN https://inspectapedia.com/heat/Oil_Burner_Wont_Run.php - found by searching InspectApedia using the search box just above, searching for oil furnace won't run or oil burner won't run
OIL BURNER MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Comments & Questions are Welcome Here
If you posted comments here and no longer see what you wrote, please check for your comment in the Reader Q&A found above on this page.
Citations & References
In addition to any citations in the article above, a full list is available on request.
[1] Brumbaugh, James E., Audel HVAC Fundamentals, Volume 2: Heating, Audel [J Wiley]; All New 4th Edition edition (July 2, 2004)
ISBN-10: 0764542079
ISBN-13: 978-0764542077, quoting from the product description,
This fully revised guidebook covers everything you need to know to install, maintain, and repair the components that run, regulate, and fuel both old and new systems. From oil burners and steam line controls to the newest chip-based technology and environmental regulations, Volume 2 helps you keep the heat on.
* Install and repair thermostats, humidistats, automatic controls, and oil or gas burner controls
* Review pipes, pipe fittings, piping details, valve installation, and duct systems
* Find new calculations and environmental guidelines
* Learn the best ways to handle hydronics and steam line controls
* Deal with solid fuels and understand coal firing methods
* Refer to data tables with conversions, formula cross-references, and manufacturers' lists
The Audel HVAC Library
Vol. 1: Heating Systems, Furnaces, and Boilers
Vol. 2: Heating System Components, Gas and Oil Burners, and Automatic Controls
Vol. 3: Air Conditioning, Heat Pumps, and Distribution Systems
[2] Beckett Corporation, 38251 Center Ridge Rd.,
North Ridgeville, OH 44039 440-327-1060 Email: sales@beckettcorp.com supplies residential and commercial oil burners for boilers, furnaces, and water heaters - see www.beckettcorp.com/
[3] Audels Oil Burner Guide, Installation, Servicing, Repairing, Frank D. Graham, 1947 edition (obsolete, out of print). See Brumbaugh, James E. Audel HVAC Fundamentals, Volume 2: Heating or see various versions of this guide available in editions from 1947, 1950, 1955, 1958, 1959, 1962, 1965, 1967, and at prices from around $3.00 to nearly $70.00 - useful for simple, clear, but not current, explanation of how heating equipment works. The original retail price was $1.00. Used copies are available
[4] A Total Look at Oil Burner Nozzles, available from Delavan Fuel Metering Products, a reference guide for oil burner service technicians, Delavan Spray Technologies, Fuel Metering Products Division, PO Box 969, Bamberg SC 29003, Tel: 800-982-6943 or 803-245-4347, ( Delavan is a division of BF Goodrich); web search 12/30/2010, original source: http://www.delavaninc.com/pdf/total_look.pdf Note & disclosure: when we (DF) were servicing oil burner equipment, Delavan nozzles gave us such excellent results, especially using hollow cone spray patterns in solving combustion problems, that this brand was our standard stock-item on our truck. Other brands of oil burner nozzles are of course also of excellent quality. It is the proper matching of nozzle size and type and spray pattern to the equipment that is critical.
[5] Fuel Nozzles for Oil Burners, Technical Aspects of Applications, E. O. Olson, Chief Engineer (deceased) Delavan Fuel Metering Products Operation, Bamberg, South Carolina, Delavan Fuel Metering Products, a reference guide for oil burner service technicians, Delavan Spray Technologies, Fuel Metering Products Division, PO Box 969, Bamberg SC 29003, Tel: 800-982-6943 or 803-245-4347, ( Delavan is a division of BF Goodrich); web search 12/30/2010, original source: http://www.delavaninc.com/pdf/Fuel_Nozzles_for_Burners.PDF
[6] Domestic and Commercial Oil Burners, Charles H. Burkhardt, McGraw Hill Book Company, New York 3rd Ed 1969.
[7] The Steam Book, 1984, Training and Education Department, Fluid Handling Division, ITT [probably out of print, possibly available from several home inspection supply companies] Fuel Oil and Oil Heat Magazine, October 1990, offers an update,
[8] Principles of Steam Heating, $13.25 includes postage. Fuel oil & Oil Heat Magazine, 389 Passaic Ave., Fairfield, NJ 07004.
[9] The Lost Art of Steam Heating, John Doe [Dan Holohan], 516-579-3046 FAX, at Amazon.com>
[10] Principles of Steam Heating, Dan Holohan, technical editor of Fuel Oil and Oil Heat magazine, 389 Passaic Ave., Fairfield, NJ 07004 ($12.+1.25 postage/handling).
[11] Principles of Home Inspection: Steam, Electric & Wall/Floor Heating, Carson Dunlop Associates, at Amazon.com>
[13] "Residential Hydronic (circulating hot water) Heating Systems", Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
[14] "Warm Air Heating Systems". Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
[15] Heating, Ventilating, and Air Conditioning Volume I, Heating Fundamentals,
[16] Boilers, Boiler Conversions, James E. Brumbaugh, ISBN 0-672-23389-4 (v. 1) Volume II, Oil, Gas, and Coal Burners, Controls, Ducts, Piping, Valves, James E. Brumbaugh, ISBN 0-672-23390-7 (v. 2) Volume III, Radiant Heating, Water Heaters, Ventilation, Air Conditioning, Heat Pumps, Air Cleaners, James E. Brumbaugh, ISBN 0-672-23383-5 (v. 3) or ISBN 0-672-23380-0 (set) Special Sales Director, Macmillan Publishing Co., 866 Third Ave., New York, NY 10022. Macmillan Publishing Co., NY
[17] Installation Guide for Residential Hydronic Heating Systems
[18] Installation Guide #200, The Hydronics Institute, 35 Russo Place, Berkeley Heights, NJ 07922
The ABC's of Retention Head Oil Burners, National Association of Oil Heat Service Managers, TM 115, National Old Timers' Association of the Energy Industry, PO Box 168, Mineola, NY 11501. (Excellent tips on spotting problems on oil-fired heating equipment. Booklet.)
[19] Crown Serviceman's Handbook: Ignition Electrode Assemblies, Terminals and Cable, Tools and Accessories, Crown Engineering Corporation, Marlboro, NJ 07746 [1986]. This publication includes oil burner troubleshooting diagnostic suggestions reprinted with permission of Fuel Oil & Oil Heat Magazine.
[21] The Wholesaler's & Installer's Guide to OEM Oil Specifications, R.W. Beckett Corporation, PO Box 1289, Elyria, OH 44036, 216-327-1060 [1988] This publication gives the model, burner type, air tube combination, head type, static plat dimensions, blower wheel dimensions, and oil burner nozzle type for just about ever manufacturer and model of oil fired heating equipment including Addison Products, Axeman-Anderson, Bard Manufacturing, BDP, Borg-Warner, Boyertown Furnace, Burnham, Carrier Corp., Clare Brothers, Columbia Boiler Co., Crown Industries, Dornback Furnace, Ducane, Dunkirk Radiator, Duo-Matic/Olsen, Electric Furnace-Man, Ener Royal Technology, Energy Kinetics, Everhot All-Corporation, F.P. Industry, Fraser-Johnston, Heat Controller, Hydrotherm Inc., Johnson Corp., Lochinvar, Logwood-Marathon Heater, Inc., Longwood Furnace Corp., Luxaire, Magic Chef, Melvin Manufacturing Corp., Metromatic Mfg. Co., Miller Heating & A/C, Modine Manufacturing, Newmac Manufacturing, New Yorker, Oneida Heater, Peerless Heater, Perfection Products, Pow-R-Matic, Inc., Reznor, Rheem Manufacturing, Ruud, Slant/Fin, H.B. Smith, State Industries, Tekton Corp., Teledyne Laars, Thermo Dynamics, Thermo Products, Trianco, Inc., Ultimate Eng., Utica Boiler, Vallant, Van Wert Manufacturing, Weil-Mclain, Williamson Co., Wise, Inc., XXth Century. But believe it or not this is not the whole list of manufacturers from the 1970's and 1980's. Reference [22] below includes a still longer list.
[22] Burnham Heating Helper, [heating system design & layout in a mini booklet], Burnham Corporation, PO Box 3089, Lancaster PA 17603, Tel: 717-481-8400, 9th printing, 7/01
Domestic and Commercial Oil Burners, Charles H. Burkhardt, McGraw Hill Book Company, New York 3rd Ed 1969.
National Fuel Gas Code (Z223.1) $16.00 and National Fuel Gas Code Handbook (Z223.2) $47.00 American Gas Association (A.G.A.), 1515 Wilson Boulevard, Arlington, VA 22209 also available from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Fundamentals of Gas Appliance Venting and Ventilation, 1985, American Gas Association Laboratories, Engineering Services Department. American Gas Association, 1515 Wilson Boulevard, Arlington, VA 22209. Catalog #XHO585. Reprinted 1989.
"Residential Hydronic (circulating hot water) Heating Systems", Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
"Warm Air Heating Systems". Instructional Technologies Institute, Inc., 145 "D" Grassy Plain St., Bethel, CT 06801 800/227-1663 [home inspection training material] 1987
Heating, Ventilating, and Air Conditioning Volume I, Heating Fundamentals,
Boilers, Boiler Conversions, James E. Brumbaugh, ISBN 0-672-23389-4 (v. 1) Volume II, Oil, Gas, and Coal Burners, Controls, Ducts, Piping, Valves, James E. Brumbaugh, ISBN 0-672-23390-7 (v. 2) Volume III, Radiant Heating, Water Heaters, Ventilation, Air Conditioning, Heat Pumps, Air Cleaners, James E. Brumbaugh, ISBN 0-672-23383-5 (v. 3) or ISBN 0-672-23380-0 (set) Special Sales Director, Macmillan Publishing Co., 866 Third Ave., New York, NY 10022. Macmillan Publishing Co., NY
Installation Guide #200, The Hydronics Institute, 35 Russo Place, Berkeley Heights, NJ 07922
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.