Heil HVAC manuals and heat pump features cited & discussed at InspectApedia.comHeil HVAC Age Decode, Manuals, Parts Lists, Wiring Diagrams

  • POST a QUESTION or COMMENT about where to find Heil furnace or boiler installation and service or maintenance manuals and guides

Heil Manuals, parts lists, wiring diagrams for HVAC equipment.

Free downloadable Heil manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps. Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for Heil who can provide that information for nearly all major brands of HVAC equipment.

Page top image: 7 features of a Heil heat pump are described in the company's split system heat pump catalog given on this page.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Heil Heaters, Furnaces, Air Conditioners, Furnaces, Boilers: parts, manuals, help

Free Heil-brand Furnace, Heat Pump, Air Conditioner Installation & Service Manuals, Wiring Diagrams, Parts Lists

Heil Tempstar ICP Carrier OLV QuietComfort87 Low boy oil furnace at InspectApdia.com

Above: the OLV QuietComfort®87 ow Boy Oil Furnace, described at the Tempstar website, a member of the ICP or International Comfort Products company, whose furnace warranty names the Carrier Corporation, and whose furnace is also sold under the Heil Heating & Cooling Products brand (Screenshot just below, 2021/05/17 taken at https://www.heil-hvac.com/en/us/products/oil-furnaces/87-low-boy-oil-furnace/)

Heil-Quaker was a Whirlpool brand, bought by Inter-City Gas, in Toronto.

ICG re-branded Whirlpool products using the Tempstar brand, and the Heil-Quaker product line is currently owned by ICP International Comfort Products who in-turn were bought by United Technologies in 1999.

Heil HVAC Age Decoder

Heil HVAC equipment manufacturing date is usually encoded in the serial number

YYWW567890

or in the serial number format

XYYWW56790

(ignore the first alphabetic character, pick up the first four numeric digits, and decode them as YYWW as we illustrate here.

Use the first four numeric digits that form YYWW where YY is year of manufacture and WW is week of manufacture in that year.

The remaining numeric digits, usually 5, form a unique serial numer or manufacturing sequence number of the equipment.

This same manufacturing date encoding appears in most HVAC equipment distributed under the ICP brands of:

Arcoaire, Comfortmaker, Heil, ICP, International Comfort Products, Inter-City Products, Keeprite, Tempstar, and UTC, United Technologies Inc.,

Heil HVAC Service Manuals, Parts Lists, Warranties

...




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

Heil SP80 furnace fan won't turn on in AC mode

I have a Heil sp80 and the fan inside the house won't kick on with AC on. The unit outside fan does kick on.

I noticed the line also frosted so i think the compressor kicked on. The blower inside the house does kick on when I turn on system heat. There was a breaker kicked when I discovered ac wasn't working. Any help greatly appreciated! On 2021-08-09 by Anonymous

Diagnostic & Repair Suggestions by inspectapedia.com.moderator (mod) -

@Anonymous,

The "fan won't start" diagnostics above on this page are a good set of things to check first; do take a look.

A tripped breaker may mean that there is a short circuit or failing fan motor - flip the breaker to OFF then back ON.

If it trips again leave it off and call for repair.

by Anonymous

@inspectapedia.com.moderator, the breaker doesn't trip again once it's flipped. Just the one time it tripped. The fan will come on if I turn system heat on.

by inspectapedia.com.moderator (mod) - Heil furnace trips breaker

@Anonymous,

That sounds to me like a control board or relay failure - since we know the fan itself works as it runs in Heat mode - but not in A/C mode.

On my Heil furnace the limit control switch needs to be replaced. Fan runs on manual, only

pretty much i think the problem is the limit control switch needs to be replaced. fan runs on manual, only. although, i did hear the fan come on by itself a week or so back. overnight, i have the themostat at 62, and fan on auto. anyway, thank you for mentioning that the honeywell module has a metal cover, which must be missing on this particular furnace.

it's a HEIL NULK075AG02 serial H611 33891. just thought, maybe the honeywell number i need is on the missing cover. anyway. the furnace may have started out LP, but is running on NG, now.

so, which honeywell part do i need? also, when i bought the inducer fan assembly last year, they gave me what i thought was a flame sensor, that i took back because i couldn't see how to install it. current one has fittings pointing up, and their replacement had horizontal which would have required bending something. force-fitting is usually an indication of a wrong choice, i find. thanks for your help On 2021-03-22 by joedave -

Diagnosic and repair tips by (mod) -

@joedave, That sounds reasonable to me. You know the fan works because you can run it on manual.

Take a look at the fan limit switch on your furnace. It's probably a standard Honeywell unit like those shown in the series.

See this FAN LIMIT SWITCH TROUBLESHOOTING guide

Note to other readers

You can find free HVAC equipment manual downloads as PDF files at

MANUALS & PARTS GUIDES - HVAC
- home - Master Index to All Brand Names & A - E HVAC manuals, wiring diagrams, installation and repair guides including for

CONSOLIDATED INDUSTRIES FURNACES information and manuals

 

How do I Fix Error Code 40 on my Heil Heat Pump

Heil Heat Pump/AC Model H4H548GKA100 has shut down. Giving error code 40? - On 2019-06-29 by Bob

Advice by Mod: Heil Heat Pump Error Code 40 Repair & Where to Fine Heil HVAC Error Code Lists

Bob

On a Heil Heat Pump an Error Code 40 tells us that there is a communications failure between the outdoor compressor/condenser unit's control board and the compressor drive chip, OR that the compressor is unable to start.

Try first just turning power off to the entire system, indoors and out, wait a few minutes, then turn power back on. While power is off, replace the air filter on your air handler.

Then turn power back on. If Error code 40 continues to be displayed I suspect a control board failure or a wiring failure such as a loose connector, or lastly, a failed compressor motor itself. You'll need an onsite HVAC service technician to test for those problems.

For more detail see the manuals and error code lists given at

HEIL ICP TEMPSTAR ERROR & STATUS CODES tables and lists found on our ICP page

For other readers, also see this

HEIL ICP TEMPSTAR 9MPT & 9MPV CONDENSING GAD FURNACES [PDF] (2001) includes error codes or status codes as LED flashes, beginning on page 40.

And here is another example of Heil or ICP HVAC Error or Status Codes, excerpted from the ICP N80ESN IO MANUAL [PDF]

[Click the image below for a larger view]

 

Where can I fiind a thermocouple for a Heil / Quaker furnace?

How do I find out what the proper part is? It's a 30 year old Heil-Quaker furnace and searches don't come up with compatible parts. I don't know if there is a standard for forced air gas furnaces. On 2017-11-10 by Dennis - need thermocouple for Heil-Quaker furnace

How do I find out what the proper part is? It's a 30 year old Heil-Quaker furnace and searches don't come up with compatible parts. I don't know if there is a standard for forced air gas furnaces.

Answer by mod - thermocouples are standard

@Dennis

See THERMOCOUPLE REPAIR / REPLACEMENT - you'll find that thermocouples are a standard, generic part, easy to locate and replace.

 

Blower Turnson too soon at Heil Furnace

I got a heil furance with a limit control

I set the dial settings at 100 second one at 140

The problem is when the flame starts before the fan on hits the the 140 setting the blower is all ready running at about 140

The flame turns off, blower turns off at about 100 - On 2017-03-17 by stan

Advice & Warning by (mod) -

I'm confused by your fan limit switch behavior description, Stan. but in our extensive FAN LIMIT SWITCH articles be sure to check

as that gives the right fan ON OFF and LIMIT settings as well as warning you about how easy it is to bend and damage the control - leaving it out of calibration and also unsafe.

The blower shouldn't be turning on until the ON number has been reached.

Watch out: if you bent the fan limit control spring behind the dial while fooling with your system the control has lost calibration and is very unsafe as your furnace could overheat.

See more details at FAN LIMIT SWITCH TROUBLESHOOTING

 

What fan limit control can replace the old R021005 switch on my old Heil Furnace?

I have a HEIL furnace that uses an R02I005 2 speed fan-limit switch, comparable to Honeywell L6064 fan-limit switch.

Both have been discontinued, can I replace it with a single speed fan-limit switch such as the Honeywell L4064B2236? On 2016-12-28 by Rob

by (mod) - contact Heil Environmental Corporate Office

Rob: provided the thermal sensor is of proper dimension that'll probably work.

Watch out: before trying to replace the old limit switch, I would give Heil a call to confirm which furnace fan limit control replacements they agree are safe.

Heil Environmental Corporate Office
2030 Hamilton Place Boulevard Suite 200
Chattanooga, TN 37421 USA
Phone: 866.367.4345
e-Mail: corp@doveresg.com

 

Heil Lincoln Series furnace short cycling problem fixed by replacing the thermostat (bad heat anticipator)

My Heil Lincoln series fuel oil furnace recently started short cycling.

The burner would kick in run for less than a minute, then kick back off.

The blower wouldn't run until 20 seconds after the burner shut off.

I eventually traced the problem back to the thermostat, a Honeywell T87F.

The anticipator must have developed a short and wouldn't respond to any adjustments I made.

Replaced it with a programmable Lux t-stat with an adjustable deadband (swing).

Your website made troubleshooting this problem go very fast. Thanks! On 2016-11-20 by Luke H

Moderator reply:

Thanks so much, Luke, we'll be sure that checking the heat anticipator for this problem is clear on our oil burner short cycling diagnostic procedure

at OIL BURNER WONT RUN

...

Continue reading at ICP INTERNATIONAL COMFORT PRODUCTS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

HEIL® HEATING & COOLING PRODUCTS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Or see

INDEX to RELATED ARTICLES: ARTICLE INDEX to HEATING SYSTEMS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT