Electromagnetic Field Measurement General Procedures
How to measure electromagnetic field exposure levels:
This article on EMF measurements explains the basics of how we can reliably measure the level of electromagnetic radiation or electromagnetic fields (EMF).
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
The Basics of Measuring Electromagnetic Field EMF Exposure Levels
Our page top photo shows a Safeco™ electromagnetic field measuring instrument. This the EMF readings that this instrument obtains are position sensitive - where you point it makes a difference even in the same spot.
As we explain at EMF RF FIELD & FREQUENCY DEFINITIONS, there is a wide range of electrical field types when arranged by frequency, from lower frequencies emitted by electrical power lines (EMF), AM and FM radio frequencies (radio towers - MF and HF or VHF), cell phones, FM and TV radio frequencies (UHF) and others in the electromagnetic spectrum.
Guide to Hiring Someone to Measure Electromagnetic Field Strengths: EMF
If a building owner or occupant is concerned about EMF or other electromagnetic field strength levels at a property (power lines, cell phone towers, radio transmitter towers, other sources), the local power company or other service providers may be willing
to perform site measurements at no charge.
Independent experts provide thorough site profiles for fees ranging from $500. to $2,500. and some include extensive
consulting which helps protect realtors from future liabilities and can calm inappropriately frightened buyers or
sellers.
But below you will read why for many circumstances we do not recommend this approach.
For electromagnetic field testing, whether it is UHF (cell phones), VHF and HF (radio towers), or EMF (power lines), and particularly for EMF testing, unless there is a legal issue that requires that the inspection and test be performed by an independent expert, you may prefer to purchase some equipment and following the procedures we’ve outlined for making an on-site survey of electrical field strengths yourself.
Particularly because the strength of electrical fields can vary enormously depending on the level of use of the emitting system, there is a risk that you hire someone at a high cost whose measurement results by no means tell you the average nor long term level of electrical field exposure at that location.
For a thoughtful, informed person who will read, it’s not technically difficult to use most electrical field measurement devices, and there are these advantages:
- the cost will be a small fraction of bringing in an independent person
- you can repeat the test under different power line load conditions (for EMF) or transmitter use cycles (RF etc). something that makes a big difference in the electrical field strength
- you can take your time and make many readings at different locations and different times of day, month, and year , being careful to be accurate
- if your object is prudent avoidance of EMF exposure (as the science is conflicted for reasons we’ve discussed), then you might find small local sources that need a change, like an electric clock by a bed headboard, or a bed headboard placed on a wall where an electrical service entry cable passes
Hiring an EMF RF consultant compared with doing it yourself
Our own personal ethical views, combined with even the most basic technical understanding of issues around RF and EMF hazards make us very reluctant to recommend hiring an "expert"
perform EMF and RF field investigations for homeowners or apartment dwellers in most circumstances. Why?
- Signal strength can be enormously variable
at a given location, depending in the case of EMF on the actual current load on the power transmission lines, and in the case of high frequency RF, on the transmission activity, antenna direction, and other factors.
As a result, momentary or single-point-in-time measurements can be quite misleading.
- Inappropriate expense?
On every environmentally fearful topic a quick industry is bred of people who are poorly trained, sometimes unethical, but who
prey on consumer fear to become wealthy - the behind the scenes comments from some of these folks can be very disturbing.
Professionals are obligated to proceed responsibly in accepting field investigation assignments, respecting both the client's physical health and their financial impacts as well.
Instead of contacting us with a request to perform EMF Electromagnetic or RF Radio Frequency Field Strength measurements,
in most cases it is more economical and convenient for a property owner to purchase their own instrument, making measurements under varying conditions. In this series of articles we describe how to make measurements using a consistent approach and using good documentation.
See EMF MEASUREMENT STEP BY STEPS for details of how to collect EMF measurement data.
Three Approaches to Measuring RF and EMF Hazards at Properties
For at least these reasons, we recommend one several different different approaches, among which you should choose
- EMF RF Exposure Litigation:
If you are involved in or anticipate litigation, then indeed it is appropriate to have a neutral third party professional make a
site investigation and to document conditions there.
- Accurate, longer term EMF or RF measurements at low cost:
If #1 does not apply, then a more informed site risk profile is one that would collect measurements over time, under different conditions of load, season of the year, transmission activity, supplemented by basic research to identify the particular source nearby and its character.
For example, if it is a power transmission line, the maximum KVA rating of the line and its distance from
the building of concern are of paramount interest, even if an instantaneous measurement gives low results. Rather than pay an independent $1800. U.S. or more to perform a single site survey, purchase the appropriate test instruments and make your own measurements, over time.
To assist in this procedure we have provided a series of articles organized
at EMF SURVEY PROCEDURE - Details.
Following good procedure and using instruments properly are two steps towards making accurate, repeatable EMF measurements.
But because the signal transmission for RF sources such as radio, TV, or cell towers, the load on a power transmission line is not under control of an individual property owner, and because the EMF strength varies as the power transmission line load varies, it is important to have an idea of that condition as well when attempting to characterize EMF exposure at a specific location.
In contrast, EMF measurements are quite accurate and repeatable at other EMF sources such as close to electrical appliances and service entry cables.
At EMF MEASUREMENT INSTRUMENT we list a number of tools that
are easy to use, but whose accuracy also depends on the actual measurement procedure - where and how measurements are obtained,
which is what we discuss in the EMF Survey Procedure article above, and for which we also provide example field data collection
sheets.
Approach #2 is likely to cost just a few hundred dollars U.S. at most, and allows longer and more extensive measurements.
- If there is a special concern
at a property, such as health complaints that appear to be building or site-related but that need
further investigation, then bringing an expert to the site is indeed more likely to be ethically and cost-justified.
Guide to Making Your Own Electromagnetic Field Strength EMF / RF Measurements

If you're simply curious about finding and measuring local EMF strengths around a home, an alternative might be to
simply purchase an inexpensive electromagnetic field strength measuring device.
But before dashing about recording
numbers, it is important to understand both the peculiarities of EMF field strength meters and the peculiarities of the
size, shape, pattern, and time variation of electromagnetic fields themselves.
Suggestions for using some sample EMF measuring instruments and a discussion of the sources of error and variation in
EMF measurements are discussed in more detail at
our EMF SURVEY PROCEDURE - Details.
At EMF MEASUREMENT INSTRUMENTS such as the TriField EMF and RF meter shown here we show several different types of EMF measuring instruments and discuss their properties.
Please do not contact us to buy equipment. We do not sell anything. To do so would be a conflict of interest for this website.
These devices are readily available from many electrical equipment and home inspection equipment suppliers.
Instead of contacting us with a request to perform EMF Electromagnetic or RF Radio Frequency Field Strength measurements,
in most cases it is more economical and convenient for a property owner to purchase their own instrument, making measurements under varying conditions. In this series of articles we describe how to make measurements using a consistent approach and using good documentation.
Following good procedure and using instruments properly are two steps towards making accurate, repeatable RF (radio frequency) or EMF (electromagnetic field) measurements.
But because the transmission from a cell tower, television tower, or the load on a power transmission line is not under control of an individual property owner, and because the RF or EMF strength varies as the power transmission line load varies, it is important to have an idea of that condition as well when attempting to characterize EMF exposure at a specific location.
In contrast, RF or EMF measurements are quite accurate and repeatable at other EMF sources such as close to electrical appliances and service entry cables.
Do not contact us with a request buy RF or EMF measuring equipment.
These devices are readily available from many electrical equipment and home inspection equipment suppliers.
See EMF MEASUREMENT INSTRUMENTS This article describes several low-cost and reasonably accurate EMF measurement devices that are readily available.
See RF RADIO FREQUENCY DETECTION METERS This article describes several low-cost and accurate radio frequency or RF detection and measurement devices suitable for radio, TV, cellphone, microwave, and similar signals.
...
ADVERTISEMENT
...
Continue reading at EMF MEASUREMENT STEP BY STEP or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
EMF MEASUREMENT PROCEDURES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & Reviewers
In addition to any citations in the article above, a full list is available on request.
- "Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields", Federal Communications Commission, Office of Engineering and Technology, US FCC, OET Bulleting 56, 4th Edition, August 1999
- "Evaluation of Potential Carcinogenicity of Electromagnetic Fields,"
EPA Report #EPA/600/6-90/005B October 1990. EPA: 513/569-7562.
- "Biological Effects of Power Frequency Electric and Magnetic Fields"
background paper, prepared as part of OTA's assessment of "Electric Power
Wheeling and Dealing: Technological Considerations for Increasing Competition,"
prepared for OTA by Indira Nair, M. Granger Morgan, H. Keith Florig, Department
of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA
15213
- "Biological Effects of Power Line Fields," New York State Powerline
Project. Scientific Advisory Board Final Report, July 1, 1987.
- "Extremely Low Frequency (ELF) Fields," Environmental Health
Criteria 35. World Health Organization, Geneva, 1984.
- "Electric and Magnetic Fields at Extremely Low Frequencies:
Interactions with Biological Systems. In: Non ionizing Radiation Protection,
World Health Organization, Regional Office for Europe, Copenhagen, 1987.
- "Electric and Magnetic Fields from 60 Hertz Electric Power: What do
we know about possible health risks?," Department of Engineering and Public
Policy, Carnegie Mellon University, Pittsburgh, PA 15213 1989.
- ICNIRP: International Commission on Non-Ionizing Radiation Protection. Health Issues related to the use of hand-held radiotelephones and base transmitters. Health Physics. 1996;70:587-593.
- IRPA, 1988, International Radiation Protection Association. Guidelines on limits of exposure to radio frequency electromagnetic fields. IEEE United States Activities, COMAR, Washington, DC.
- NCRP, 1986, National Council on Radiation Protection. Biological effects and exposure criteria for radiofrequency electromagnetic fields. Report 86, (Bethesda, MD: National Council on Radiation Protection and Measurements) pp. 1-382.
- Rothman KJ, Chung-Kwang C, Morgan R, et al. Assessment of cellular telephone and other radio frequency exposure for epidemiologic research. Epidemiology. 1996;7:291-298.
- Valberg PA. Radio frequency radiation (RFR): the nature of exposure and carcinogenic potential. Cancer Causes Control. 1997;8:323-332.
- Wolf R, Wolf D. Increased incidence of cancer near a cell-phone transmitter station. Int J Cancer Prevention 2004;1:123-128.
- World Health Organization (WHO). Electromagnetic fields and public health: base stations and wireless technologies. 2006. Accessed at www.who.int/mediacentre/factsheets/fs304/en/index.html on February 23, 2010.
- In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
CONTINUE READING or RECOMMENDED ARTICLES.