Overview of how to measure EMF exposure levels & field strengths:

This paper provides an overview of the recommended procedure for performing electromagnetic field (EMF) or electro-magnetic radiation EMR measurements either by engaging a professional or by consumers using low-cost instruments which measure EMF exposure levels in gauss or milligauss.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





An Overview of an EMF/EMR Measurement Survey Procedure

bar magnet shows the typical shape of an electromagnetic field

Because RF and EMF measurement tools need to be properly chosen to measure the particular type and frequency of RF or EMF signal that is of interest, be sure to also

see EMF RF FIELD & FREQUENCY DEFINITIONS for a simple explanation of different types of radio frequency (RF) and electromagnetic frequency (EMF) types and where they are found.

Magnetic fields are directional; measurements are affected by position as well as location

of the instrument within the area being examined, and by the distance of the instrument from the field source.

Our field experience strongly suggests that results are quite variable depending on the particular direction aimed and positions held when using the measuring instrument.

Therefore, and consonant with recommendations from the manufacturers, each of our "measurements" is derived from at least three instrument readings, holding the instrument pointed at a suspected field source (e.g. nearby power line), pointed straight up, and held horizontally. Horizontal and vertical measurements are recorded as the highest obtained following a 360 degree scan of the area with the instrument held in that position.

During such a rotation in the presence of a strong magnetic field we find reading levels ranging widely.

We warn that measurements made by another professional will not duplicate our results unless our exact procedure is used with an instrument of similar performance at the identical locations. However our experience is that measurements with similar instruments in approximately the same locations and circumstances, produce results which are quite close.

For each instrument reading we record

 location, position, meter sensitivity settings, meter readings, and estimated distance to the suspected field source, if any. We also record observations of devices such as TV's or computers if they are seen operating nearby.

For the analog device measurements, actual meter readings are converted to milli/microgauss using tables provided by the instrument manufacturer based on the sensitivity range to which the instrument was set at time of use.

A range of sensitivity settings are required to protect this very delicate instrument from being damaged by the fields being measured. The manufacturer describes a mathematical procedure which we follow to combine these data into a single field level number for an area being measured.

For the digital device measurements, actual measurements are read on the instrument in gauss or milligauss, depending on a field strength sensitivity selection on the meter.

Electrical utility pole worker in San Miguel de Allende (C) Daniel Friedman As with any potential poison, our concerns are first to establish a dose-relationship to effects of the poison, and next to establish a reliable way to measure the actual dose or exposure that a person may experience.

Electrical Utility Workers and EMF Exposure

It's apparent that electrical utility workers, especially people who spend a good part of their working day up close to power transmission lines and electrical power stepdown transformers are likely to have higher exposure to electrical fields and EMF than occupants of a typical residential building.

We recommend close monitoring and scrutiny of the soundness of studies that are performed to examine the health effects of EMF exposure for this population.

Please see WORKPLACE EXPOSURE to Electromagnetic Fields for details about EMF exposure in the work place.

We include example EMF exposure limits and research citations below.

Please do not contact us with a request buy EMF or RF measuring equipment. We do not sell anything. To do so would be a conflict of interest for this website.

These EMF measuring and survey devices are readily available from many electrical equipment and home inspection equipment suppliers.

See Evaluation of Low-Cost EMF Instruments

This article describes several low-cost and reasonably accurate EMF measurement devices that are readily available.

See Radio Frequency RF Detection Meters

This article describes several low-cost and accurate radio frequency or RF detection and measurement devices suitable for radio, TV, cellphone, microwave, and similar signals.


...





ADVERTISEMENT





...

Continue reading at EMF LOCAL SOURCES MAY EXCEED POWER LINE STRENGTH or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

 

Suggested citation for this web page

EMF/EMR MEASUREMENT OVERVIEW at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING ENVIRONMENT

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Questions & answers or comments about the basic approaches to measuring the level of exposure to EMF electromagnetic fields in the home or workplace.

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & Reviewers

In addition to any citations in the article above, a full list is available on request.

  • "Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields", Federal Communications Commission, Office of Engineering and Technology, US FCC, OET Bulleting 56, 4th Edition, August 1999

    " Many consumer and industrial products and applications make use of some form of electromagnetic energy. One type of electromagnetic energy that is of increasing importance worldwide is radiofrequency (or "RF") energy, including radio waves and microwaves, which is used for providing telecommunications, broadcast and other services.

    In the United States the Federal Communications Commission (FCC) authorizes or licenses most RF telecommunications services, facilities, and devices used by the public, industry and state and local governmental organizations.

    Because of its regulatory responsibilities in this area the FCC often receives inquiries concerning whether there are potential safety hazards due to human exposure to RF energy emitted by FCC-regulated transmitters. Heightened awareness of the expanding use of RF technology has led some people to speculate that "electromagnetic pollution" is causing significant risks to human health from environmental RF electromagnetic fields.

    This document is designed to provide factual information and to answer some of the most commonly asked questions related to this topic.
    " - original source: U.S. Federal Communications Commission Office of Engineering and Technology, http://www.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet56/oet56e4.pdf
  • "Evaluation of Potential Carcinogenicity of Electromagnetic Fields," EPA Report #EPA/600/6-90/005B October 1990. EPA: 513/569-7562.
  • "Biological Effects of Power Frequency Electric and Magnetic Fields" background paper, prepared as part of OTA's assessment of "Electric Power Wheeling and Dealing: Technological Considerations for Increasing Competition," prepared for OTA by Indira Nair, M. Granger Morgan, H. Keith Florig, Department of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA 15213
  • "Biological Effects of Power Line Fields," New York State Powerline Project. Scientific Advisory Board Final Report, July 1, 1987.
  • "Extremely Low Frequency (ELF) Fields," Environmental Health Criteria 35. World Health Organization, Geneva, 1984.
  • "Electric and Magnetic Fields at Extremely Low Frequencies: Interactions with Biological Systems. In: Non ionizing Radiation Protection, World Health Organization, Regional Office for Europe, Copenhagen, 1987.
  • "Electric and Magnetic Fields from 60 Hertz Electric Power: What do we know about possible health risks?," Department of Engineering and Public Policy, Carnegie Mellon University, Pittsburgh, PA 15213 1989.
  • "Electromagnetic Fields Are Being Scrutinized for Linkage to Cancer," Sandra Blakeslee, New York Times, Medical Science section, April 2, 1991
  • Electric Power Lines, Electromagnetic Fields, Cancer Risk, & "Enviro-Scare" - The Normal Curve Cycle of Public Fear of Environmental Issues
  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested

    CONTINUE READING or RECOMMENDED ARTICLES.


ADVERTISEMENT