MagicPak HVAC manufacturer contact information and direct links to free downloadable installation, service, and users manuals, focusing on hard-to-find manuals for older models or discontinued equipment.

We also provide links to the manufacturer's current model lists and literature.

Free downloadable manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps. Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturers who can provide that information.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





MagicPak Packaged Heating & Cooling Systems Manuals, Parts, Contact

Magic-PakĀ® packaged heating and cooling and heat pump systems  cited & discussed at InspectApedia.com - this is the M-series unitFree Magic Pak HVAC Furnace, Heat Pump, Air Conditioner Installation & Service Manuals, Wiring Diagrams, Parts Lists

Contact: Magic-Pak, 215 Metropolitan Drive, West Columbia, SC 29170 USA Tel: 800-448-5872 Product Support 866-282-7257 Website: https://www.magic-pak.com/

Magic-Pak is a brand of Allied Air Enterprises Llc, A Lennox International Inc. Company

Magic-Pak MGE4 Heater & Air Conditioner Manual at InspectApedia.com The Magic-Pak MGE4 unit, illustrated just below, uses gas fueled heat and R410A refrigerant cooled air conditioning in a self-contained unit (no outside compressor/condenser unit).

Also see LENNOX HVAC MANUALS & PARTS GUIDES Industries Air Conditioners, Furnaces, Heat Pumps , Manuals, Guides

Magic-Pak Serial Number & Age Decoder Guide

How do I Find the Age of my Magic Pack HVAC?

Our InspectApedia reader asked:

How old my magic pack HVAC? I have no idea, but I have the model number and serial number. - Charlie 10/9/11

Reply:

In the references section below we include links to some serial number decoding guide books that may be able to help you pinpoint the age of your Magic Pack HVAC system - the year is coded in the serial number.

Look for the MagicPak serial number on the data tag or sticker on the front panel of your unit or on its top or side.

If you don't see a data tag on the outside of your unit, look inside the access covers.

Then find the serial number, where on most units the year of manufacture is in the second two digits, such as we show the following example:

MagicPak Serial # 8810B12345 where the serial number is #NNYYA12345 where YY is the year of manufacture.

So in our example, that Magic-Pak unit was manufactured in the 2010.

We've found four Magic-Pak Serial Number Formats whose details we give just below.

  1. nnYYMnnnn where YY is the year of manufacture and M is the Month and where the alphabetic Month code is decoded as follows

Month Code

Month
A January
B February
C March
D April
E May
F June
G July
G August
J September
K October
L November
M December

Notes to the table above

To avoid confusion Magic-Pak does not use the letter "I" in month coding.

  1. AnnnnnMYA where A = an alphabetic character, Y is an alphabetic OR numeric year date code given in the table below, and M is an alphabetic month code as given in our month table above. The lower case n designates other numerical portions of the serial number.

Year Code for Magic-Pak Serial Number Format 2

Year
8 1978
9 1979
A 1980
B 1981
C 1982
D 1983
E 1984
F 1985
G 1986
G 1987
J 1988
K 1989
L 1990
M 1991
N 1992

Notes to the table above

  1. DDMYY AAnnn where DD = day and M month of manufacture (see the Month Table above on this page) and a two-digit year is encoded backwards, for example if YY reads as = 67 the actual year of manufacture is 1976. The last three digits of this serial number is unique to the equipment on the day it was produced.
  2. nnnnnnYYWW where YY is the year of manufacture and WW is the week of manufacture in of course a 52-week year.

Magic-Pak Model Number Decoder Guide

Using the MAGICPAK PACKAGED HEAT PUMP UNIT MGE4 SPECIFICATIONS [PDF] (2019) as an example, here is a typical Magic-Pak HVAC system Model Number Decoder that identifies the product's coolling and heating capacity in BTU/Hr or KW along with refrigerant type and other features.

Magic-Pak MHP4 Model Number Decoder Guide at InspectApedia.com

...

Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

MAGICPAK HVAC MANUALS & PARTS GUIDES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Or see

INDEX to RELATED ARTICLES: ARTICLE INDEX to HEATING SYSTEMS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia