1958-59 Asphalt Asbestos Floor Tile Identification Key
Photo guide to Armstrong brand asphalt asbestos and vinyl asbestos floor tiles made and sold in 1958 and 1959.
This article series provides a guide to identifying asphalt-asbestos flooring (1917 - ca 1960) & vinyl asbestos floor tile (ca 1952 - 1986) - these flooring products typically contain chrysotile asbestos, and possibly other asbestos forms.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

For colors for which a link is not provided below, see the earlier occurrence of that tile color in a previous year.
Excelon CORKSTYLE 9 x 9 x 1/16" thick floor tile pattern was not recommended for heavy traffic areas
Colors: as shown below, Armstrong Excelon cork patterns from left to right:
DARK 799, shown above and the full set shown below:
MEDIUM 797, LIGHT 798, and DARK MEDIUM Corkstyle No. 800.
Below: the four shades of Armstrong Excelon corkstyle floor tiles in 1958 from an Armstrong Excelon floor tile catalog, cited at the end of this page.
[Click to enlarge any image]
Below: Excelon DESIGNER SERIES floor tile pattern
Excelon designer series floor tiles were provided in Colors: Sand Beige 762, Maur tiles for 1958, (tile size not given, presumed 9 x 9)
available in 1/16" & 1/8" in these colors: Mint Green 760, Silver Gray 761, Mauve Taupe 764, Rose Taupe 765, Sienna Copper 765,
IVORY TAN 766 - new in 1958, shown above,
ECRU 767 (See other color examples from 1957)
Also see this DESIGNER SERIES INSTALLED FLOOR example (below):
Excelon STRAIGHT GRAINED 9 x 9 x 1/16" & 1/8" thick floor tile patterns No. 767 made in 1958 is shown above.
Colors: POWHATAN TURQUOISE No. 787 shown above - See more straight grain asphalt-asbestos floor tile color examples from 1957
Excelon WOODTONE 9 x 9 x 1/16" or 1/8" thick floor tile pattern
Colors:
(Light Woodtone 788, Dark Woodtone 789,
REDWOODTONE 796 - new this year, shown above - for photos of this floor tile in other colors, see 1957
Excelon EXETER RED SPATTER 9 x 9 x 1/16" thick floor tile pattern series, shown below sold this year only as Exeter Red 741

Colors Andover White 735, Bedford Gray 736, Cape Cod Beige 737, Lexington Green 738, Providence Charcoal 739, Arlington Cedar 740,
EXETER RED 741 (above() Concord Yellow 742, Norwich Turquoise 743, Bangor Copper 744, Plymouth Pink 745) See other color examples given as this same floor was produced
in 1957
Below: catalog of Armstrong Excelon Spatter pattern floor tiles from the 1958 Catalog given at the end of this page.
[Click to enlarge any image]
By 1959 it was common to see the word "vinyl" replacing "asphalt" in Armstrong's floor tile catalogs, as we illustrate just below.
[Click to enlarge any image]
For Armstrong floor tile colors for which a link is not provided below, see the earlier occurrence of that tile color in a previous year.
Excelon CORKSTYLE pattern vinyl asbestos floor tiles sold in 9 x 9 x 1/16" light duty use in these colors: (See more corkstyle vinyl-asbestos floor color images from 1956, 1957)
EXCELON IMPERIAL Floor Tile Patterns
Colors:
ARBOR GREEN No. 862 shown above for 1959
For similar tiles see vinyl asbestos flooring images from 1959 - 1960
Excelon Metallic Series Floor Tiles New in 1959-60, see the 1960 information below sold in these colors: (Photos needed - uncertain if this tile was produced in 1959)
Metallic Series Excelon 9x9x 1/16" or 3/32" thickness gauge floor tiles were sold in one pattern, and in four colors
Colors: Taupe bronze 355, BLACK GOLD 351 (shown below) Gray silvergold 354, and Redwood gold 353.
EXCELON SPATTER PATTERN Floor Tiles, examples below:
Colors:
(DORSET BLACK 732 - new this year,
CORNWALL BLUE No. 733 above, Andover White 735, Bedford Gray 736, Cape Cod Beige 737, Rutland Beige 746, Worcester Gray 749 )
EXCELON STRAIGHT GRAINED FLOOR TILES Grained Floor Tiles (See tile pattern & color photos from prior years + the examples above and below)
Colors:
1959 CHIPPEWA GRAY No. 703 shown above, 1960
MOHAVE CHARCOAL No. 786 shown below
EXCELON STYLETONE - shown above in Cedartone 835, Floor Tiles (New in 1959)
Colors:
SANDSTONE 830, above
MINTONE 831, shown above
IVORYTONE 833, below
ROSETONE 834, below
CEDARTONE No. 835 shown below
Below: Redwoodtone No. 796, a wood or cedar wood pattern floor tile.
Woodtone Excelon Floor Tiles (see 1957-58 photos earlier on this page) Redwoodtone No. 796, shown just above.
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
I have lifted the carpet in my 1950s house and found these Armstrong tiles.
They are lovely and, provided I do not tamper with them, they are safe if sealed.
I need about 3 metres more to complete the floor. The red one, I think is Apache red 777 and the beige I am unsure. Where can I get the additional tiles please? On 2020-09-11 by julie archer
Answer by (mod) - Nowhere safe
Julie I seriously doubt that you will find anyone able much less willing to sell 1950s through early 1980s asbestos containing floor tiles, though on occasion on eBay and etsy and similar websites we find people offering old boxes of floor tiles for sale.
Better would be to find a modern non-asbestos lookalike floor tile to patch the lost tiles, then read
Where can I send a picture of my tiles to see if there asbestos or not if anyone can recognize it. On 2020-01-29 by Diane
Suggestion by (mod)
Diane
You can use the add image button to post a photo with your comment.
But best is to look through the photo guides given in this article series yourself, or see the guidance at
DOES THIS FLOORING CONTAIN ASBESTOS?
Where can I find the make up of Cayuga Brown #715 by Armstrong 9 x 9 inch tile ? wondering also if the backing is made of asbestos ? - On 2018-09-10 by Nancy -
Reply by mod
You will need to guess at the probable age of your floor tiles, then see
DOES THIS FLOOR CONTAIN ASBESTOS? - 5 easy questions to tell if your FLOOR probably contains asbestos -
Hi I recently purchased a home that was built in 1950. I'm concerned about the tile on in the hall way and in the kitchen. However, by chance I measured the til in the hall way and it was 6 x 6. Do you have any information on 6 x 6 tile.
I didn't measure the tile in the kitchen, but I believe it is the same size. I've attached pictures. Hopefully you can point me in the right direction. On 2018-05-13 by Rhemy
Answer by (mod): probably yes
Indeed depending on the manufacturer asbestos-containing floor tile was made in 6 by 6, 9 by 9, 12 x 12, and also custom sizes.
...
Continue reading at ASBESTOS FLOOR IDENTIFICATION PHOTOS 1960-1969 or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
ASBESTOS FLOOR TILE IDENTIFICATION PHOTOS 1958-1959 at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.