Causes of Loss of Water Pump PrimeThis article explains the reasons why a water or well pump loses prime. Understanding the cause of lost well prime will guide just what repairs are needed so that it doesn't keep happening.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
If your water pump is in the building and the pump keeps losing its prime,
a shallow well jet pump well line could have a bad foot valve (in the well) and so be losing prime.
A leak in the well line can also lead to loss of prime.
If priming the well water pump using one of our methods shown below seems to fix the problem but soon the well pump loses prime again, your plumber will want to check for a bad foot valve in the well or a leak in the well piping between the well and the building.
...
Bottom line: Not directly but if there's a check valve or well pipe leak you lose prime during the power outage.
Often a long-existing but small leak at a check valve or in well piping or even in the pump body itself may go undiscovered as long as the pump has electrical power. As water leaks out of the pump and piping the water pressure drops and periodically the pump simply turns on and pumps water pressure back up well before the pump has "gone dry".
But when there is a power outage that lasts long enough that same leak will lead to complete loss of pump prime.
The clue that this condition exists in a building is the observation that the pump seems to run periodically when we think that no one is using water.
Detailed diagnosis and repair for this problem are at See WATER PUMP INTERMITTENT CYCLING where we discuss common sources of unanticipated operation of the well pump.
...
Our reader asked:
Would a leaking or non-tightened prime plug make a 2 line jet pump lose prime overnight? On 2022-10-25 by Joe -
Reply by InspectApedia (Editor) - yes, especially if there's a bad check valve too
@Joe,
That could happen particularly if there is also a leaky check valve or foot valve - the priming plug allows air into the system.Besides reading the article above on tihs page see these helpful FAQs pages
SIGNS that the WATER PUMP HAS LOST ITS PRIME FAQs - the pump chamber is dry and pump won't deliver water
...
Continue reading at WATER PUMP PRIMING PROCEDURE, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see CAUSES of LOST WELL PUMP PRIME FAQs questions & answers posted originally on this page.
Or see these
CAUSES of LOST WELL PUMP PRIME at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.
In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com
We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.
In addition to any citations in the article above, a full list is available on request.