Master Water Softeners
This article provides manuals and contact information for Master water softeners.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
Master Water Conditioners / Water Softeners

Above: photo of the control head for the Master 155 Series Water Conditioner. Photos & manuals of this Master Water Softener were provided courtesy of InspectApedia reader Dean Grantham (October 2017).
- Contact: Master Water Conditioners, 224 Shoemaker Rd., Pottstown, PA 19464 USA, Tel: 215-323-8358, Website: http://www.masterwater.com/
Master Water Conditioner Equipment Manuals: http://www.masterwater.com/customer-care/ including the company's current product line, MBA series (MBA, MP, NS, TS, TC) and MCA series (MCA, MP CNS, CTS, CNS) water treatment equipment.
Master Water Conditioners
has been in the water conditioning business in the U.S. since 1967, producing a combined water filter and water softener system, adding UV disinfection, membrane filtration, sulfur treatment (their manganese-based Simplus system), and other treatments such as sediment removal. The company's current (2017) series of products include the MBA series and MCA series water treatment equipment.
The company's website Contact form provides for contact but does not give a corporate address.
- MASTER WATER CONDITIONER CONTROL SYSTEM Series 155 I&O MANUAL [PDF] (July 1990) includes instructions of adjusting the water softener timer shown above, the water softner brine control adjustment (the salt dial), and other features.
- Master Water Conditioner AUTOMATIC FILTER INSTALLATION & OPERATION GUIDE [PDF] Models MBA-AC-10 / 13 (carbon filter), MBA-AN-10 / 13 (Neutralizer), MBA-FE-10 / 13 (Iron Filter), MBA-AN-10 / 13, MBA-S-10 / 13 (Sediment Filter)
- IDENTIFY WATER SOFTENER BRAND / MODEL [web article] where we list common water conditioners alphabetically by brand name provides identification photos for the Series 155 unit illustrated here and whose manual is given below.
- MASTER WATER CONDITIONER MBA 10/20 COMBINATION UNIT
MANUAL [PDF] with the
255/742 Logix Control Valve
With Vortech, (2006) retrieved 2017/10/23, original source http://www.masterwater.com/wp-content/uploads/PDFs/consumers/literature/ combination-units/manuals/mba-series/ 42_MBA-10T-20T-Combination-Manual.pdf
- MASTER WATER CONDITIONER MBA 30/40T MANUAL [PDF] (2006) op. cit.
- MASTER WATER CONDITIONER MP NS 30T 40T IO MANUAL [PDF] (2006) op. cit.
- MASTER WATER CONDITIONER MCA COMBO MANUAL [PDF] (2011) op. cit.

Above: sketch showing the key controls on the control head for the Master 155 Series Water Conditioner.

Above and below, control details for Master 155 Series water conditioner.
... 
Manuals and photos of the Master 155 Series water conditioner were provided courtesy of InspectApedia reader Dean Grantham (October 2017).
...
Continue reading at WATER SOFTENER ADJUSTMENT & CONTROLS, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
Master WATER SOFTENERS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & References
In addition to any citations in the article above, a full list is available on request.
ADVERTISEMENT