Autotrol Water Softener Manuals
Autotrol Water Softener Operating & Maintenance Manuals & Guides
Where to find the manual for your water conditioner or water softener.
Direct links to free, download-able water softener manuals or water conditioner manuals for many Autotrol water softener brands & models.
Select the correct installation or operation & repair manual for your Autotrol water softener brand and model to be sure that you have exactly the right instructions for installing, maintaining, or troubleshooting your water conditioner.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
Autotrol Pentair Water Softeners & Water Conditioner Manuals, Logix™ Controllers
The following list of water softener or water conditioner manuals is for all water softeners beginning with Autotrol;
Above: the Autotrol Logix 460TC softener control, also sold as Pentair 460i/460TC - the manual for this control is given in the list below.
- Contact: Aquatell (Nelsen Corporation) produces Autotrol Water Conditioners. Email: sales@aquatell.com Tel: Toll Free 1-866-966-9951 Website: Toll Free 1-866-966-9951 Website: http://www.aquatell.com/
- AUTOTROL 155-400 CONTROL MANUAL [PDF] Water Conditioning Control System, Installation, Operation, Maintenance Manual for the Series 155 Valve & 440 Control (1996) from Osmonics Autotrol, used on many water softeners sold under various brand names including Autotrol and Kisco water softeners.
Also see Osmonics controls below on this page.
- AUTOTROL® 255 Water Conditioning Control System Valve 255 Valve / 400 Series Controls, Home Owner Installation, Operation & Service Manual", [PDF] (2009), Pentair Residential Filtration, LLC.
- AUTOTROL SERIES 255 VALVE / 460i Water Conditioning Control System, Installation, Operation, and Maintenance Manual, web search 09/01/2010 original source: http://www.qualitywatertreatment.com/PDF/Autotrol%20255-460i_Manual.pdf
- AUTOTROL 255 VALVE 960 CONTROL WATER CONDITIONER I&O MANUAL [PDF] (1999)
- AUTOTROL 155 Valve / 440 CONTROL MANUAL [PDF] (1996)
- AUTOTROL LOGIX™ 255-760 METER WATER SOFTENER MANUAL - Installation & Startup Instructions, [PDF] retrieved 2017/09/16, original source: https://www.qualitywaterforless.com/ v/vspfiles/ downloadables/LOGIX/255760INS.pdf QualityWaterForLess.com
956 S Bartlett Rd. #288, Bartlett, IL 60103 USA Tel: 888-426-5001 Email: info@qualitywaterforless.com Website: https://www.qualitywaterforless.com/,
- AUTOTROL LOGIC 460i/460TC WATER SOFTENER CONTROL HEAD MANUAL [PDF] (2011) also sold as Pentair
- AUTOTROL LOGIX™ 740 / 760 WATER SOFTENER MANUAL with Series 255 & Performa Control Valve [PDF] This is the Logix™ Series Softener System, Op. Cit.
- AUTOTROL PERFORMA VALVE w/ 400-SERIES CONTROL MANUAL [PDF] (2001), Op. Cit.
- [2] Autotro® 255 Valve / 400 SERIES CONTROLS, Water Conditioning Control System, Home Owner Installation, Operation, and Maintenance Manual, Pentair Residential Filtration, LLC, 2009
- [3] AUTOTROL® Series 255 Valve / 460i Water Conditioning Control System, Installation, Operation, and Maintenance Manual, web search 09/01/2010 original source: http://www.qualitywatertreatment.com/PDF/Autotrol%20255-460i_Manual.pdf
- [4] Aquatell (Nelsen Corporation) produces Autotrol Water Conditioners. Email: sales@aquatell.com Tel: Toll Free 1-866-966-9951 Website: Toll Free 1-866-966-9951 Website: http://www.aquatell.com/
- Also see GE WATER SOFTENER MANUALS
- Also see PENTAIR WATER SOFTENER MANUALS
Pentair covers these brands: Autotrol, Everpure, Fleck, Industrial Filtration, Pentair, Pentex, Siata, Structural, WellMate
...
ADVERTISEMENT
Reader Comments, Questions & Answers About The Article Above
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
Where to get a manual for an Eliminator Pro-Series water softner
Hello! We are not sure if our water softener is working or not?
Desperately need to find a manual for the Eliminator Pro-Series 48 Water Softener. Does anyone have a copy to share or any advice? Thank you, Laurie
@Laurie Kukurin,
Sure
Take a look at this Alpha Plus ELIMINIATOR PRO WATER SOFTENER MANUAL [PDF] and compare that with your unit.
Also because this softener often uses an Autotrol control head be sure to see the Autotrol resources on this page.
Autotrol 460i water softener controller settings when number of occupants is less
I have an Autotrol 460i water softener controller. The original settings were for a family of 4 and were
Hardness=11; Capacity=24 and Brine=8 and the water was at an acceptable soft level.
The family has decreased to 2 recently and we have noticed that the water is no longer soft. Is this a setting issue or some other maintenance related issue like resin becoming old or the valve has something wrong? Thanks.
Reply by (mod)
First check the salt tank, then try a manual regen cycle; Also have the water tested for hardness as that level could have changed and thus would require a softener adjustment
Thanks. The salt tank is full and appears fine. I will try the manual regeneration cycle and see if that makes a difference.
When to regenerate an Autotrol Performa Prosoft Water Softener
I have a Autotrol Performa Prosoft.
I'm told it should regenerate at "0" capacity. I noticed it was regenerating at 50, then 80. Now it regenerates at around 150 gallons. I have had the Culligan man here twice for this issue. The first time, I guess he thought I didn't know what I was talking about.
When he had to come back for free, he asked me again what it was doing. After I explained, he said he had no clue and would have to ask around.
I am being ignored now. The first time he was here, he said my water had more iron so he increased the hardness. My unit is now regenerating every other day when it was going about once a week before.
So I get a little over 400 gallons at regeneration but at 150, it dumps and goes again! My unit is 12 years old.
...
Continue reading at WATER SOFTENER ADJUSTMENT & CONTROLSor select a topic from closely-related articles below, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
AUTOTROL WATER SOFTENER MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & Reviewers
In addition to any citations in the article above, a full list is available on request.
- [1] North Dakota Standards for Water Softeners, North Dakota General Authority Law, Chapter 62-04-08, Water Softener Units http://www.legis.nd.gov/information/acdata/pdf/62-04-08.pdf. "The objective of this chapter is to provide a standard of quality, capacity,
and performance for water softener units. Water softener performance
is to be based upon referee tests procedures described in section
62-04-08-09."
- [3] Water Softeners, CMHC, Canadian Mortgage and Housing Corporation, cmhc-schl.gc.ca/en/co/maho/wawa/wawa_005.cfm - October 2008. Canada Mortgage and Housing Corporation acknowledges the contribution of Health Canada to the development of this document. For further questions regarding water treatment and water quality, contact Health Canada at watereau@hc-sc.gc.ca or call 613-957-2991 or 1-866-225-0709.
- [11] "Commercial Water Softener Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia) for commercial, industrial and residential application www.ibcwater.com.au (07) 3219 2233
- [12] "Non electric water softener,
Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia), op.cit.
- [13] "Water Softener Twin Tank Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia), op.cit.
- [15] Andress, S., and C. Jordan. 1998. Onsite Sewage Systems. Virginia Polytechnic Institute and State University, Civil Engineering Department, Blacksburg, VA.
- [16] Corey, R.B., E.S. Tyler, and M.U. Olotu. 1997. Effects of Water Softer Use on the Permeability of Septic Tank Seepage Fields. In Proceedings of Second National Home Sewage Treatment Symposium. Pub. no. 5-77. American Society of Agricultural Engineers, St. Joseph, MI.
- In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested