Ideal Boiler & Logic Combi Manuals
Manuals, parts lists, wiring diagrams for Ideal Boilers including the Logic Combi ESP1 series models 24 35 35 heater & instant hot water boiler.
This website provides free downloadable manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps.
We include links to contact information for each manufacturer or producer of these air conditioners, heat pumps, furnaces, boilers and related equipment, parts, and installation, repair, wiring diagrams, manuals.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Be sure to see details about each of these error codes as explained in the manual for your specific heater.
Ideal Boiler Error / Fault Codes |
|
| Code | Meaning |
| dU | (Logic Combi ESP1) Diverter Valve in mid-position for Service |
| F | (Logic Combi) Boiler frost protection - boiler will fire if temperature is below 5 degrees C. |
| FD | No water flow |
| F1 | Low water pressure |
| F2 | Flame loss |
| F3 | Fan fault |
| F4 | Thermistor failure |
| F5 | Return thermistor failure |
| F6 | Outside sensor fault |
| F7 | Low voltage (Mains) |
| F9 | Circuit board fault |
| FA | (Logic Combi ESP1)Negative Differential Flow.Return Thermistor |
| FU | (Logic Combi ESP1)Flow/Return Differential > 50°C |
| L1 | Water flow weak or temperature too high or too low |
| L2 | Ignition lockout |
| L3 | No flow, thermistor fault |
| L4 | (Logic Combi ESP1)Flow Thermistor |
| L5 | (Logic Combi ESP1)Return Thermistor |
| L9 / H9 / HA / LA | Same as L1 or (Logic Combi) Unconfigured PCB |
| LC | (Logic Combi ESP1)5 Boiler Resets in 15 Minutes |
| LF | Ignition fault |
| L56 | Return pipe Too many resets (> 5 in 15 min) |
| L6 | Flame detection fault |
| C0 | Central heating signal failure |
| C2 | Boiler chip card failure |
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
How do I reset my logic combo 35 boiler to resume hot water I only have cold.
- Betty, 2022/06/20
This Q&A were posted originally
Moderator reply: Logic Combi 35 Boiler Restart Procedure
@Betty,
Thanks for that helpful question.
FIRST try the simple Logic Combi 35 Reset Instructions given by the manufacturer.
Logic Combi ESP1-Series BOILER RESTART PROCEDURE
To restart the boiler press the RESTART button.
The boiler will repeat the ignition sequence if a heat demand is present.
If after that the heater won't run, check the error code on the display at the top of the unit in that little square window.
I don't have a clear image of the error code displayed on your Logic Combi 35 heater photo, but I think I see just an "F" showing
If you don't have the user's manual for your Ideal Logic Combi 35 heater, download this
IDEAL LOGIC COMBI HEATER USERS MANUAL [PDF] at
https://inspectapedia.com/heat/Ideal-Logic-combi-esp1-Manual.pdf
**OR**
Your Logic Combi 35 may be one of the older older Logic Combi boilers before the ESP1-series.
In that manual we see that the "F" code alone signifies
Boiler frost protection - boiler will fire if temperature is below 5 degrees C.
Your heater's display suggests that the right manual for your unit may be the
IDEAL LOGIC COMBI 24,30,35 USERS GUIDE [PDF] (2015) - older models similar to those in the manual just above.
For that boiler here is the reset procedure:
Logic Combi 24 30 35 RESET PROCEDURE
To reset boiler, turn the mode control knob (D) to reset position and immediately turn knob back to required setting.
The boiler will repeat the ignition sequence.
If the boiler still fails to light consult a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII).
...
Continue reading at TANKLESS WATER HEATERS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
IDEAL HEATING BOILERS - UK at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
If you posted comments here and no longer see what you wrote, please check for your comment in the Reader Q&A found above on this page.