InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile Phone/PDA website viewMobile View
INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT

ACOUSTICAL SEALANT CHOICES
AIR BYPASS LEAKS
AIR LEAK MINIMIZATION
AIR LEAK SEALING PROCEDURE

ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS FLOORING REMOVAL GUIDE
ASBESTOS IDENTIFICATION IN BUILDINGS
ASBESTOS LIST of PRODUCTS
ASBESTOS MATERIAL REGULATIONS
ASBESTOS PHOTO GUIDE to Materials
ASBESTOS RISK ASSESSMENT
ASBESTOS REMOVAL, Wetting Guidelines
ASBESTOS ROOFING / SIDING DUST
Asbestos Under the Microscope

ATTIC LEAKS, CONDENSATION & MOLD
ATTIC VENTILATION

BASEMENT CEILING VAPOR BARRIER
BASEMENT HEAT LOSS
BASEMENT LEAKS, INSPECT FOR
BASEMENT WATERPROOFING
BATH & KITCHEN DESIGN GUIDE
BATHROOM VENTILATION

BLOWER DOORS & AIR INFILTRATION
BLOWER FAN CONTINUOUS OPERATION
BLOWER FAN OPERATION & TESTING
BLOWN-IN INSULATION

BOOKSTORE - INTERIORS
BRICK LINED WALLS
BRICK VENEER WALL INSULATION
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BUCKLED FOUNDATIONS due to INSULATION?
BUILDING NOISE DIAGNOSIS & CURE

CABINETS & COUNTERTOPS
Carbon Nanotube Materials
CACTUS FUNGI / MOLD
CAR MOLD CONTAMINATION
CARPET DUST IDENTIFICATION
CARPET MOLD CONTAMINATION
CARPET TEST PROCEDURE
CARPETING & INDOOR AIR QUALITY
CARPETING, SELECTION & INSTALLATION

CATHEDRAL CEILING INSULATION
CATHEDRAL CEILING VENTILATION
CEILING FINISHES INTERIOR
CEILINGS, DROP or SUSPENDED PANEL
CEILINGS, PLASTER TYPES
CEILINGS, PLASTER, LOOSE HAZARDS
CEILING TILES - Asbestos-Containing

CONDENSATION or SWEATING PIPES, TANKS

CRAWL SPACES
  CRAWL SPACE DRYOUT PROCEDURES
  CRAWL SPACE GROUND COVERS
  CRAWL SPACE INSULATION RETROFIT
  CRAWL SPACE SAFETY ADVICE
  CRAWL SPACE VAPOR BARRIER
  CRAWLSPACE MOLD ADVICE
  MOLD CLEANUP by MEDIA BLASTING
  MOLD ON DIRT FLOORS

DEFINITION of Heating & Cooling Terms
  Definition of BTUs, BTUH, & Calories
  Definition of K value K-coefficient heat transmission
  Definition of U value or U-coefficient heat loss resistance
  Definition of R-Values for Insulation or Buildings
  Definition of Design Temperature for Buildings
  Definition of Heating or Cooling "Degree Day"
  Definition of Tons of Cooling Capacity
DECK & PORCH CONSTRUCTION
DEW POINT CALCULATION for WALLS
DEW POINT TABLE - CONDENSATION POINT GUIDE

ENERGY SAVINGS in BUILDINGS
  AFUE DEFINITION, RATINGS
  AIR BYPASS LEAKS
  AIR CHANGE RATE ACH HEAT SAVINGS
  AIR CONDITIONING HEAT PUMP SAVINGS
  AIR LEAK SEALING PROCEDURE
  APPLIANCE EFFICIENCY RATINGS
  ATTIC LEAKS, CONDENSATION & MOLD
  COOLING LOAD REDUCTION by ROOF VENTS
  DRYER VENTING
  ENERGY AUDIT - How to Use a Free One
  ENERGY SAVINGS MAXIMIZE RETURNS ON
  ENERGY SAVINGS PRIORITIES
  ENERGY SAVINGS RETROFIT CASE STUDY
  ENERGY SAVINGS RETROFIT LEAK SEALING GUIDE
  ENERGY SAVINGS RETROFIT OPTIONS
  ENERGY STAR PROGRAM
  ENERGY USE MONITORING
  GLASS vs HEAT MIRROR SOLAR GAIN/Loss
  HEAT LOSS in BUILDINGS
  HEATING COST SAVINGS METHODS
  HIGH MASS TRADEOFFS, HEATING vs COOLING
  HOUSE DOCTOR, how-to be
  INSULATION INSPECTION & IMPROVEMENT
  INSULATION LOCATION - WHERE TO PUT IT
  RADIANT BARRIERS
  REFLECTIVE INSULATION
  ROOF COLOR RECOMMENDATIONS
  Skylight Energy Efficiency
  SOLAR ENERGY SYSTEMS
  THERMAL MASS in buildings
  TIMERS for ELECTRIC WATER HEATERS
  VENTILATION, BALANCED HEAT COST SAVINGS
  WIND ENERGY SYSTEMS
  WINDOW EFFICIENCY Features & Ratings
  WOOD, COAL STOVES & FIREPLACES

ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

FIBERGLASS HAZARDS
  Recognizing Fiberglass Insulation
  Recognizing Fiberglass Duct Insulation
  Lab Identification of Fiberglass
  Fiberglass Fragment Hazards
  Fiberglass Detection in Building Air
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  MOLD PREVENTION AFTER FLOODING
  MOLD RESISTANT CONSTRUCTION
  Mold in Foam Insulation
  Actual mold growth in insulation
  Moldy insulation may look clean
  Why does mold grow in fiberglass?
  When to test insulation for mold

FIBERGLASS INSULATION
FIBERGLASS PARTICLE CONTAMINATION TEST
Fiberboard Insulation Sheathing Mold
Fiberglass Enviro-Scare
FIBERGLASS INSULATION MOLD
Fireproofing containing Asbestos
FRAMING DETAILS for BETTER INSULATION
FRAMING DETAILS for DOUBLE WALL HOUSES
FRAMING METAL STUD PERFORMANCE
FREEZE-PROOF A BUILDING
FROST HEAVES, FOUNDATION, SLAB

HEAT LOSS RATE CALCULATIONS
HEAT LOSS in BUILDINGS
  How to measure heat movement through a wall
  How to measure building insulation
  How leaky is the building
  BASEMENT CEILING VAPOR BARRIER
  BASEMENT De-Watering Systems
  BASEMENT HEAT LOSS
  ENERGY AUDIT - How to Use a Free One
HEAT LOSS DETECTION TOOLS
HEAT LOSS INDICATORS
HEAT LOSS PREVENTION PRIORITIES
HEAT LOSS R U & K VALUE CALCULATION

HOUSEWRAP AIR & VAPOR BARRIERS
HOUSEWRAP INSTALLATION DETAILS
HOUSEWRAP at SILLS, SOLES, TOP PLATES

HUMIDITY LEVEL TARGET

ICE DAM PREVENTION

INDOOR AIR QUALITY & HOUSE TIGHTNESS

INSULATION CHOICES
Insulation Air & Heat Leaks
INSULATION FACT SHEET- DOE

INSULATION IDENTIFICATION GUIDE
  ASBESTOS-FREE INSULATION MATERIALS
  ASBESTOS IDENTIFICATION IN BUILDINGS
  Asbestos Pipe Insulation
  Balsam Wool Batt Insulation
  BLOWN-IN INSULATION
  BRICK LINED WALLS
  BRICK VENEER WALL INSULATION
  Cellulose loose fill insulation
  Ceramic Insulation
  Concrete insulation, light-weight
  Cotton Insulating Batts
  FIBERGLASS DUCT, RIGID CONSTRUCTION
  Fiberglass Insulation
  Foam Board Insulation
  Foam Insulation Types - Visual Id
  Homasote & Other Insulating Board
  Icynene Foam Spray Insulation
  Insects & Foam Insulation
  Mineral Wool - Rock Wool Insulation
  Paper Duct Insulation
  Perlite Insulation
  PHENOLIC FOAM INSULATION
  POLYISOCYANURATE FOAM INSULATION
  POLYISOCYANURATE FOAM BELOW SLABS
  POLYSTYRENE FOAM INSULATION
  RADIANT BARRIERS
  REFLECTIVE INSULATION
  RIGID FOAM USE INDOORS
  STRESS SKIN INSULATED PANELS
  STUCCO OVER FOAM INSULATION
  SUPER HI-R INSULATION
  SUPERINSULATION RETROFIT
  Urea Formaldehyde Foam Insulation UFFI
  URETHANE FOAM Deterioration, Outgassing
  VERMICULITE INSULATION


INSULATION INSPECTION & IMPROVEMENT
  Air Bypass Leaks, Thermal Tracking
  AIR LEAK DETECTION TOOLS
  AIR LEAK MINIMIZATION
  AIR SEAL STRATEGIES
  ASBESTOS IDENTIFICATION IN BUILDINGS
  ATTIC CONDENSATION CAUSE & CURE
  BASEMENT CEILING VAPOR BARRIER
  BASEMENT De-Watering Systems
  BASEMENT HEAT LOSS
  Blocked Soffit Intake Vents
  BLOWER DOORS & AIR INFILTRATION
  BLOWN-IN INSULATION
  BRICK or BLOCK WALL CAVITY INSULATION
  BRICK VENEER WALL INSULATION
  BUCKLED FOUNDATIONS due to INSULATION?
  CASEWORK, CABINETS, SHELVING INSTALLATION
  CATHEDRAL CEILING INSULATION
  CATHEDRAL CEILING VENTILATION
  HOT ROOF DESIGNS: Un-Vented Roof Solutions
  ENERGY SAVINGS in BUILDINGS
  ENERGY AUDIT - How to Use a Free One
  ENERGY SAVINGS MAXIMIZE RETURNS ON
  ENERGY SAVINGS PRIORITIES
  ENERGY SAVINGS RETROFIT CASE STUDY
  ENERGY SAVINGS RETROFIT LEAK SEALING GUIDE
  ENERGY SAVINGS RETROFIT OPTIONS
  ENERGY STAR PROGRAM
  ENERGY USE MONITORING
  FIBERGLASS DUCT, RIGID CONSTRUCTION
  Fiberglass Insulation
  FIRE PROTECTION FOR FOAM BOARD INSULATION
  FOUNDATION INSULATION OPTIONS
  FRAMING DETAILS for BETTER INSULATION
  FRAMING DETAILS for DOUBLE WALL HOUSES
  FRAMING METAL STUD PERFORMANCE
  HEATING COST SAVINGS METHODS
  HIGH MASS TRADEOFFS, HEATING vs COOLING
  HOUSE DOCTOR, how-to be
  Inspect Attics for Moisture or Mold
  Inspect Attics for Blocked Soffit Intake Vents
  Inspect Basements for Moisture or Mold
  Inspect Building Exterior - Roof Venting
  Inspect the Ridge Vent System from the Attic
  Inspect the Soffit Vent System from the Attic
  Insects & Foam Insulation
  Insulation Air & Heat Leaks
  INSULATION for GREENHOUSE or SOLARIUM
  INSULATION CHOICES
  INSULATION FACT SHEET- DOE
  INSULATION PLACEMENT in BUILDINGS
  INSULATION R-Values & Properties
  LOG HOME WALL INSULATION VALUES
  MOISTURE in BUILDING WALLS, EFFECTS
  MOISTURE in CELLULOSE INSULATION
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  MOLD in Foam Insulation
  MOLD in INSULATION
  Mold Resistance of Foam Insulation
  MOLD PREVENTION AFTER FLOODING
  MOLD RESISTANT CONSTRUCTION
  PASCAL CALCULATIONS
  PASSIVE SOLAR DESIGN METHOD
  PHENOLIC FOAM INSULATION
  POLYISOCYANURATE FOAM INSULATION
  POLYISOCYANURATE FOAM BELOW SLABS
  POLYSTYRENE FOAM INSULATION
  RADIANT BARRIERS
  REFLECTIVE INSULATION
  RIGID FOAM USE INDOORS
  ROOF VENTING ENERGY SAVING DETAILS
  ROOF VENTING NEEDED?
  ROOF VENTILATION SPECIFICATIONS
  SLAB INSULATION LOCATION
  SLAB INSULATION LOCATION & EXTENT
  SLAB INSULATION, PASSIVE SOLAR
  SLATE THERMAL MASS for SOLAR HEAT STORAGE
  SOUND CONTROL in BUILDINGS
  STRESS SKIN INSULATED PANELS
  STUCCO OVER FOAM INSULATION
  SUPER HI-R INSULATION
  SUPERINSULATION RETROFIT
  Urea Formaldehyde Foam Insulation UFFI
  URETHANE FOAM Deterioration, Outgassing
  VAPOR BARRIERS & AIR SEALING at BAND JOISTS
  VAPOR BARRIERS & CONDENSATION in BUILDINGS
  VAPOR BARRIERS & HOUSEWRAP
  VAPOR CONDENSATION & BUILDING SHEATHING
  VERMICULITE INSULATION


INSULATION LOCATION - WHERE TO PUT IT
  BLOWN-IN INSULATION
  INSULATION CHOICES
  INSULATION FACT SHEET- DOE
  INSULATION LOCATION & QUANTITY for ATTICS
  INSULATION LOCATION for BASEMENT FLOORS
  INSULATION LOCATION for BASEMENT WALLS
  INSULATION LOCATION for BRICK or BLOCK WALL CAVITY
  INSULATION LOCATION for BRICK VENEER WALLS
  INSULATION LOCATION for CAPES, CRAWLSPACES
  INSULATION LOCATION for CATHEDRAL CEILINGS
  INSULATION LOCATION for GREENHOUSE or SOLARIUM
  INSULATION LOCATION for PASSIVE SOLAR FLOOR SLAB
  INSULATION LOCATION & EXTENT for SLABS
  INSULATION LOCATION for SOUND CONTROL
  INSULATION LOCATION for SUSPENDED PANELS
  INSULATION LOCATION for SWIMMING, INDOOR

INSULATION MOLD
INSULATION R-Values & Properties

KIT HOMES, Aladdin, Sears, Wards, Others
KITCHEN & BATH DESIGN GUIDE
KITCHEN VENTILATION

LEED GREEN BUILDING CERTIFICATION
LEED Building Designation & IAQ

LOG HOME ENERGY EFFICIENCY
LOG HOME GUIDE

MOLD in FOAM INSULATION, RESISTANCE

MOISTURE CONTROL in BUILDINGS
MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS
MYCOPHOBIA, STAINS MISTAKEN for MOLD
MYCOTOXIN EFFECTS of MOLD EXPOSURE

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE
NOISE, AIR CONDITIONER COMPRESSOR
NOISE, DUCT VIBRATION DAMPENERS
NOISE CONTROL for HEATING SYSTEMS
NOISE CONTROL for FLOORS
NOISE CONTROL for PLUMBING
NOISE CONTROL for ROOFS
NOISES COMING FROM WATER HEATER

ODORS & SMELLS DIAGNOSIS & CURE
ODOR DIAGNOSIS CHECKLIST

PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
Paper Duct Insulation Containing Asbestos
PASCAL CALCULATIONS

PASSIVE SOLAR DESIGN METHOD
PASSIVE SOLAR HEAT PERFORMANCE
PASSIVE SOLAR HOME, LOW COST
PHOTOVOLTAIC POWER SYSTEMS

RADIANT BARRIERS
RADIANT HEAT
RADIANT HEAT Floor Mistakes to Avoid
RADIANT HEAT TEMPERATURES
RADIANT SLAB FLOORING CHOICES
RADIANT SLAB TUBING & FLUID CHOICES
REFLECTIVE INSULATION
RIGID FOAM USE INDOORS

ROT, FUNGUS, TERMITES
ROT, TIMBER FRAME

SAFETY HAZARDS & INSPECTIONS
SEARS KIT HOUSES
SHEATHING, FOIL FACED - VENTS
SLAB INSULATION, PASSIVE SOLAR

SOUND CONTROL in BUILDINGS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on BUILDINGS - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STAINS & FINISHES, INTERIOR
STAINS on INDOOR SURFACES: PHOTO GUIDE

STAIRS, RAILINGS, LANDINGS, RAMPS
STONE CLEANING METHODS
STRAW BALE CONSTRUCTION
STRESS SKIN INSULATED PANELS

STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES
SUMP PUMPS GUIDE
SWEATING (CONDENSATION) on PIPES, TANKS


THERMAL EXPANSION of MATERIALS
THERMAL MASS in buildings
  THERMAL MASS FLOOR SLABS
  THERMAL MASS in UPSTAIRS
  THERMAL MASS WALL DESIGN
  THERMAL MASS in HOMES - STUDY
  THERMAL MASS TRADEOFFS, HEATING vs COOLING
THERMAL TRACKING & HEAT LOSS
  Ceiling Thermal Tracking Marks
  Wall Thermal Tracking Stains
  Floor Carpet Thermal Tracking Stains
  Air Bypass Leaks Marks on Insulation
  Thermal Tracking to Diagnose IAQ
  Stains HVAC Supply Registers
  Pet Stains on Floors
  Pet Stains on Walls
  Human Occupant Stains on Walls
  Stains from Candles, Woodstoves, Fireplaces
  Other Stains on Indoor Walls & Ceilings
  What to Do About Thermal Tracking

THERMOSTATS, HEATING / COOLING

TRIM, INTERIOR INSTALLATION

TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

VAPOR BARRIERS & CONDENSATION in BUILDINGS
  ATTIC CONDENSATION CAUSE & CURE
  BASEMENT CEILING VAPOR BARRIER
  CONDENSATION or SWEATING PIPES, TANKS
  CRAWL SPACE VAPOR BARRIER
  DEW POINT CALCULATION for WALLS
  DEW POINT TABLE - CONDENSATION POINT GUIDE
  FELT 15# ROOFING, as HOUSEWRAP/VAPOR BARRIER
  HOUSEWRAP AIR & VAPOR BARRIERS
  HOUSEWRAP INSTALLATION DETAILS
  HOUSEWRAP PRODUCT CHOICES
  HOUSEWRAP at SILLS, SOLES, TOP PLATES
  HUMIDITY LEVEL TARGET
  MOISTURE CONTROL in BUILDINGS
  RAIN SPLASH-UP SIDING DAMAGE
  VAPOR BARRIERS & AIR SEALING at BAND JOISTS
  VAPOR BARRIERS & CONDENSATION in BUILDINGS
  VAPOR BARRIERS & HOUSEWRAP
  VAPOR CONDENSATION & BUILDING SHEATHING
  WATER BARRIERS, EXTERIOR
  WOOD SIDING FLASHING DETAILS

VENTILATION in BUILDINGS
  VENTILATION DESIGN PROBLEMS & SOLUTIONS
  VENTILATION, WHOLE HOUSE STRATEGIES

WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in BUILDINGS
WIND WASHING INSULATION At EAVES
WINDOWS & DOORS
WINTERIZE A BUILDING
WOOD Burning Heaters Fireplaces Stoves

More Information

Photograph of chopped fiberglass insulation Photograph of chopped fiberglass insulation

How to Inspect & Correct Building Insulation & Ventilation
InspectAPedia®  -      

  • Insulation & Heat Loss Inspection Guide; Insulation R-values, Types, & other characteristics
  • Building ventilation and moisture problems, causes, cures: indoor air quality
  • Attic, basement, & crawl space condensation - mold problems, mold solutions
  • Fiberglass in buildings: hazards & remedies
  • Mold growth problems on or in building insulation
  • Ice dam causes and ice dam prevention
  • Stain diagnosis in buildings; air leaks, thermal tracking or telegraphing
  • Ventilation of building attics, crawl spaces, & other
  • Questions & answers about identifying & troubleshooting building insulation & ventilation systems

This article series discusses how to inspect, diagnose and correct problems in building insulation or ventilation systems. We also describe how to install or repair building insulation & ventilation systems including using stains and other clues to diagnose air movement, heat loss or moisture problems.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

The links at page left and lists below describe the topics in this InspectAPedia.com article series. Our page top photos show inadequate attic insulation that was also a mold , rodent, and insect allergen reservoir in a building (above left) and frost in the attic at the roof eaves in a building lacking proper insulation and ventilation.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Guide to Inspection of Building Insulation & Ventilation Systems, insulation material identification, insulation R-values, insulation characteristics

The websites and articles listed here provide in-depth discussions of how to identify various types of insulation and building ventilation systems, including where insulation or ventilation defects occur and what is their effect on buildings, and we discuss various indoor air quality issues involving building insulation such as asbestos and fiberglass particle contamination, mold in insulation, and building moisture and condensation where insulation and ventilation have not been properly installed.

Insulation products are used in a very wide range of building products and building locations besides attic, ceiling, and wall insulation. Some kinds of insulation can be tricky to identify and may have special concerns which are discussed in these articles.

Links at page left organize our articles on building insulation inspection, hazards, and insulation properties. Additional insulation articles are listed just below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

  • ACOUSTICAL SEALANT CHOICES - use of sealants or tapes to seal polyethylene vapor barrier lap joints
  • AIR BYPASS LEAKS - how dark stains on building walls, ceilings, and insulation can show up thermal bypass leaks and heat loss
  • AIR LEAK DETECTION TOOLS - how to find and fix air and heat leaks on buildings, an expert guide to weatherization
  • AIR LEAK MINIMIZATION - how to retrofit a building to tighten a leaky house
  • AIR SEALING STRATEGIES - different strategies for sealing a leaky building to save energy
  • Asbestos pipe insulation in buildings how to identify asbestos pipe insulation, how to inspect and report its condition
  • ATTIC CONDENSATION CAUSE & CURE - a complete guide to
  • Balsam Wool Batt Insulation - properties
  • BASEMENT HEAT LOSS - where and how to insulate basements and foundation walls
  • BASEMENT MOLD includes examples of moldy fiberglass insulation found in basements
  • Blocked Soffit Intake Vents - cause of building moisture problems, ice dams, leaks
  • BLOWER DOORS & AIR INFILTRATION - how to measure air leaks, equivalent leakage area (ELA), and air changes per hour (ACH) in a building
  • BLOWER FAN OPERATION & TESTING
  • BLOWN-IN INSULATION
  • BRICK or BLOCK WALL CAVITY INSULATION and  BRICK VENEER WALL INSULATION - insulating masonry building walls and masonry veneer walls
  • BRICK LINED WALLS - Brick "Insulation" in Building Walls how inspect, report, and repair brick nogging, or solid brick "insulation" in antique building walls
  • BRICK VENEER WALL INSULATION
  • BUCKLED FOUNDATIONS due to INSULATION? - does insulating the foundation lead to frost damage or collapse?
  • CASEWORK, CABINETS, SHELVING INSTALLATION - how to prevent cold kitchen cabinets and cold dishes
  • CATHEDRAL CEILING INSULATION - how to properly insulate and ventilate cathedral ceilings and enclosed roof cavities
  • CATHEDRAL CEILING VENTILATION - where and how to get venting working in a cathedral ceiling
  • Cellulose loose fill insulation - cellulose blown-in insulation or loose-fill properties, mold resistance, moisture properties, odors, R-values
  • Ceramic Insulation - properties
  • Concrete insulation, light-weight - properties
  • Convective Loops & Thermal Bypass Leaks - how air movement in interior partitions steals heat from buildings
  • Cotton Insulating Batts - properties
  • CRAWLSPACE MOLD includes additional examples of moldy fiberglass insulation found in crawl spaces
  • ENERGY SAVINGS in BUILDINGS - complete list of building energy savings articles
  • ENERGY SAVINGS RETROFIT OPTIONS includes ultra lightweight concrete insulation, insulating forms for concrete foundations
  • Fiberglass Insulation - properties
  • FIRE PROTECTION FOR FOAM BOARD INSULATION - the importance of covering exposed foam insulation products used indoors
  • Foam Board Insulation - properties.
  • Foam Insulation Spray Product Guide: If you are having trouble determining what type of foam insulation product has been installed in a building, see How to Make a Sure Distinction Among UFFI, Icynene, and Latex Foam Insulations for detailed on the identification of these products in the field.
  • FOUNDATION INSULATION OPTIONS - where, how, how much insulation to put inside or outside foundation walls
  • FRAMING DETAILS for BETTER INSULATION - avoid cold spots, air leaks
  • GREENHOUSE or SOLARIUM - insulation for
  • HEAT LOSS RATE CALCULATIONS, Insulation Properties, Definitions of R, K, U values, Insulation Design
  • HEATING COST SAVINGS METHODS - set priorities for savings on heating costs
  • Homasote & Other Insulating Board - properties
  • HOT ROOF DESIGNS: Un-Vented Roof Solutions - evaluation of un-vented roof designs, durability, risks
  • NewHOUSE DOCTOR, how-to be - where to get tools, test equipment, training to find heat loss & air leaks in buildings
  • HOUSEWRAP AIR & VAPOR BARRIERS - do we need to use house wrap products like Typar® and Tyvek®? How should they be installed?
  • How to Choose an Air Conditioner - BTU Chart useful when buying or replacing an air conditioner, this chart helps select the proper sized air conditioning unit
  • How to Detect and Correct Attic Condensation & Prevent Ice Dam Leaks in Buildings
  • How to Inspect Building Interiors and Building Insulation/Ventilation list of articles about building insulation inspection, defects, design, and ventilation requirements
  • Icynene Foam Spray Insulation - properties
  • Inspection Procedure for Insulation Defects & Problems:
    •   Inspect Attics for Moisture or Mold
        Inspect Attics for Blocked Soffit Intake Vents
        Inspect Basements for Moisture or Mold
        Inspect Building Exterior - Roof Venting
        Inspect the Ridge Vent System from the Attic
        Inspect the Soffit Vent System from the Attic
       
  • Insects & Foam Insulation -
  • INSULATION CHOICES - what are the options, costs, benefits, R-values, properties of different insulations? Also see INSULATION R-Values & Properties
  • INSULATION PLACEMENT in BUILDINGS - how and where to place insulation
  • Insulation Materials as Indicators of Building Age various types of insulation were used in different eras of construction
  • Indoor Air Quality Investigations: Fiberglass in Indoor Air, HVAC ducts, and Building Insulation
  • INSULATION for GREENHOUSE or SOLARIUM - how to retrofit night time heat loss insulation and concrete floor slab insulation
  • Insulation Identification Photographs - Fiberglass insulation photos, yellow, pink, green, white fiberglass identification in building attics, walls, ducts, other locations
  • Insulation Identification Photographs - Cellulose insulation photos, Mineral wool insulation photos, rock wool insulation photos, cotton insulation photos, balsam wool insulation photos
  • Insulation Identification Photographs - Vermiculite insulation photos
  • Insulation Properties, Table of R-Values, density, moisture permeability, fire safety, aging effects on various insulation materials
  • LOG HOME WALL INSULATION VALUES - discusses the insulation value of solid log wall homes compared with other structures, and it explains the principal errors people make when evaluating the cause of chilly log cabins.
  • LP or Natural Gas Pressures & BTUH per Cubic Foot how to properly install, inspect, and test gas piping and gas installations
  • Mineral Wool - Rock Wool Insulation - properties
  • Mold in building insulation: see these articles
    •   Mold in Fiberglass Insulation
        Mold on Books, Book Conservation
        Mold on Fiberboard Insulating Sheathing
        MOLD in Foam Insulation
        MOLD in INSULATION
        Mold Resistance of Foam Insulation
        MOLD RESISTANT CONSTRUCTION
        MOLD PREVENTION AFTER FLOODING
  • Moisture Problems: Causes and Cures. Understanding moisture problems can steer you free of trouble, Steve Bliss: Building it Right, Solar Age, March 1983 p. 37, 38. -- Adapted with permission, from original material to form this web page article.
  • Mold in Fiberglass in Insulation hidden mold can be a serious contamination problem in fiberglass insulation that has been wet, even though mold is not visible
  • Mold in Foam Insulation what is the risk of mold, rot, or other damage when solid foam or spray foam insulation is used in building cavities
  • Paper Duct Insulation - may include asbestos paper
  • PASCAL CALCULATIONS
  • PASSIVE SOLAR DESIGN METHOD
  • Perlite Insulation - properties
  • PHENOLIC FOAM INSULATION - properties
  • POLYISOCYANURATE FOAM INSULATION - any hazards associated with indoor use? Also see POLYISOCYANURATE FOAM BELOW SLABS.
  • POLYSTYRENE FOAM INSULATION - comparison of EPS and XEPS for foundation insulation
  • RADIANT BARRIERS - how do radiant heat barriers work in buildings, how should they be installed, how effective are radiant heat barriers, what about "radiant barrier insulation" products such as ALFOL™?
  • Radiant Heat Floor Mistakes to Avoid case history of improper placement of slab insulation and radiant heat tubing - don't let your contractor ruin your costly in-floor heating system as ours did
  • RIGID FOAM USE INDOORS - fire safety and fire barriers
  • Roof ventilation and how it works with building insulation. See:
    •   ROOF VENTING ENERGY SAVING DETAILS
        ROOF VENTING NEEDED?
        ROOF VENTILATION SPECIFICATIONS
  • SLAB INSULATION, PASSIVE SOLAR
  • SLATE THERMAL MASS for SOLAR HEAT STORAGE
  • SOUND CONTROL in BUILDINGS - principles of sound transmission, soundproofing designs, materials, details
  • STRESS SKIN INSULATED PANELS - properties, construction, history, durability study
  • STUCCO OVER FOAM INSULATION - choices of insulation and support for stucco over foam insulation over masonry walls
  • SUPER HI-R INSULATION - properties, cost effectiveness, uses
  • SUPERINSULATION RETROFIT
  • Urea Formaldehyde Foam Insulation UFFI - history, hazards, public worries. Also see URETHANE FOAM Deterioration, Outgassing
  • Un-Vented Roof Solutions - How to Prevent Attic Condensation, Ice Dam Leaks, Roof Mold, & Roof Structural Damage in Buildings with Un-vented Roof Cavities
  • VAPOR BARRIERS & CONDENSATION in BUILDINGS - causes of and problems from building condensation; where and why to install vapor barriers, how to install vapor barriers in buildings
  • VAPOR BARRIERS & HOUSEWRAP - do we need to use house wrap products like Typar® and Tyvek®? How should they be installed?
  • VERMICULITE INSULATION - some may contain asbestos
  • VENTILATION in BUILDINGS - home page for complet list of building insulation & ventilation installation, specifications, guides, troubleshooting articles
      VENTILATION, WHOLE HOUSE STRATEGIES - in depth article on methods to ventilate homes,types, concepts, design
  • Vermiculite Building Insulation & Asbestos
  • VENTILATION, WHOLE HOUSE STRATEGIES, including Guide to Sizing House Ventilation, Whole House Ventilation Table, Installation of Whole House Ventilation, VENTILATION, EXHAUST ONLY, Single-Port Exhaust Venting,, Multiport Exhaust Venting, Ventilating Heat-Pump Systems,, VENTILATION, SUPPLY-ONLY, Forced-Air Supply Ventilation and Multiport Supply Ventilation

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

INSULATION INSPECTION & IMPROVEMENT

  • "Controlling Moisture in Log Homes" and the more general (but brief) DOE article series on moisture control:
  • Ice Dam Leaks in building attics and roof cavities, how to inspect for evidence of leaks, identify causes, and correct bad attic ventilation, improper roof venting, and these causes of attic mold or roof structure damage
  • "Minimizing Air Leakage in Log Homes"
  • "Ventilation", U.S. DOE, describes the purpose of building ventilation and three basic ventilation strategies:
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • "Vapor Barriers or Vapor Diffusion Retarders", U.S. DOE: how vapor barriers work, types of vapor diffusion barriers, installing vapor barriers
  • "Moisture Problems: Causes and Cures. Understanding moisture problems can steer you free of trouble", Steve Bliss: Building it Right, Solar Age, March 1983 p. 37, 38. -- Adapted with permission, from original material to form this web page article.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson Dunlop The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop, and from the InspectAPedia bookstore. The 2010 edition of the Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
  • Asbestos: How to find and recognize asbestos in Buildings - visual inspection methods, list of common asbestos-containing materials
  • Asbestos HVAC Ducts and Flues field identification photos and guide
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print).
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • ASHRAE resources on building insulation, dew point and wall condensation - see the ASHRAE Fundamentals Handbook, available in many libraries. The following three ASHRAE Handbooks are also available at the InspectAPedia bookstore in the third page of our Insulate-Ventilate section:
    • 2005 ASHRAE Handbook : Fundamentals : Inch-Pound Edition (2005 ASHRAE HANDBOOK : Fundamentals : I-P Edition) (Hardcover), Thomas H. Kuehn (Contributor), R. J. Couvillion (Contributor), John W. Coleman (Contributor), Narasipur Suryanarayana (Contributor), Zahid Ayub (Contributor), Robert Parsons (Author), ISBN-10: 1931862702 or ISBN-13: 978-1931862707
    • 2004 ASHRAE Handbook : Heating, Ventilating, and Air-Conditioning: Systems and Equipment : Inch-Pound Edition (2004 ASHRAE Handbook : HVAC Systems and Equipment : I-P Edition) (Hardcover)
      by American Society of Heating, ISBN-10: 1931862478 or ISBN-13: 978-1931862479
      "2004 ASHRAE Handbook - HVAC Systems and Equipment The 2004 ASHRAE HandbookHVAC Systems and Equipment discusses various common systems and the equipment (components or assemblies) that comprise them, and describes features and differences. This information helps system designers and operators in selecting and using equipment. Major sections include Air-Conditioning and Heating Systems (chapters on system analysis and selection, air distribution, in-room terminal systems, centralized and decentralized systems, heat pumps, panel heating and cooling, cogeneration and engine-driven systems, heat recovery, steam and hydronic systems, district systems, small forced-air systems, infrared radiant heating, and water heating); Air-Handling Equipment (chapters on duct construction, air distribution, fans, coils, evaporative air-coolers, humidifiers, mechanical and desiccant dehumidification, air cleaners, industrial gas cleaning and air pollution control); Heating Equipment (chapters on automatic fuel-burning equipment, boilers, furnaces, in-space heaters, chimneys and flue vent systems, unit heaters, makeup air units, radiators, and solar equipment); General Components (chapters on compressors, condensers, cooling towers, liquid coolers, liquid-chilling systems, centrifugal pumps, motors and drives, pipes and fittings, valves, heat exchangers, and energy recovery equipment); and Unitary Equipment (chapters on air conditioners and heat pumps, room air conditioners and packaged terminal equipment, and a new chapter on mechanical dehumidifiers and heat pipes)."
    • 1996 Ashrae Handbook Heating, Ventilating, and Air-Conditioning Systems and Equipment: Inch-Pound Edition (Hardcover), ISBN-10: 1883413346 or ISBN-13: 978-1883413347 ,
      "The 1996 HVAC Systems and Equipment Handbook is the result of ASHRAE's continuing effort to update, expand and reorganize the Handbook Series. Over a third of the book has been revised and augmented with new chapters on hydronic heating and cooling systems design; fans; unit ventilator; unit heaters; and makeup air units. Extensive changes have been added to chapters on panel heating and cooling; cogeneration systems and engine and turbine drives; applied heat pump and heat recovery systems; humidifiers; desiccant dehumidification and pressure drying equipment, air-heating coils; chimney, gas vent, fireplace systems; cooling towers; centrifugal pumps; and air-to-air energy recovery. Separate I-P and SI editions."
    • Principles of Heating, Ventilating, And Air Conditioning: A textbook with Design Data Based on 2005 AShrae Handbook - Fundamentals (Hardcover), Harry J., Jr. Sauer (Author), Ronald H. Howell, ISBN-10: 1931862923 or ISBN-13: 978-1931862929
    • 1993 ASHRAE Handbook Fundamentals (Hardcover), ISBN-10: 0910110964 or ISBN-13: 978-091011096
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Construction Waterproofing Handbook, Michael T. Kubal. Quoting:
    ... an all-inclusive, project-simplifying guide for waterproofing and construction professionals. This comprehensive answer-packed resource is loaded with the up-to-date, clearly-defined information you need on every project, including work on the building envelope, below-grade, above-grade, and remedial waterproofing.
  • Brick nogging used as soundproofing is mentioned in this article on Popular Forest
  • Brick Nogging, Historical Investigation and Contemporary Repair, Construction Specifier, April 2006. Historical use of brick in timber-framed buildings, drawing on the investigations of the Kent Tavern in Calais, VT. "Brick nogging is a European method of construction which was brought to the new world in the early-nineteenth century. It was a common construction method that employed masonry as infill between the vertical uprights of wood framing." -- quoting the web article review.
  • Photo of very rough in-wall brick nogging at an architects website
  • Dust from the World Trade Center collapse following the 9/11/01 attack: the lower floors of this building contained spray-on fire-proofing asbestos materials.
  • "Energy Savers: Whole-House Supply Ventilation Systems [copy on file as /interiors/Energy_Savers_Whole-House_Supply_Vent.pdf ] - ", U.S. Department of Energy energysavers.gov/your_home/insulation_airsealing/index.cfm/mytopic=11880?print
  • "Energy Savers: Whole-House Exhaust Ventilation Systems [copy on file as /interiors/Energy_Savers_Whole-House_Exhaust.pdf ] - ", U.S. Department of Energy energysavers.gov/your_home/insulation_airsealing/index.cfm/mytopic=11870
  • "Energy Savers: Ventilation [copy on file as /interiors/Energy_Savers_Ventilation.pdf ] - ", U.S. Department of Energy
  • "Energy Savers: Natural Ventilation [copy on file as /interiors/Energy_Savers_Natural_Ventilation.pdf ] - ", U.S. Department of Energy
  • "Energy Savers: Energy Recovery Ventilation Systems [copy on file as /interiors/Energy_Savers_Energy_Recovery_Venting.pdf ] - ", U.S. Department of Energy energysavers.gov/your_home/insulation_airsealing/index.cfm/mytopic=11900
  • "Energy Savers: Detecting Air Leaks [copy on file as /interiors/Energy_Savers_Detect_Air_Leaks.pdf ] - ", U.S. Department of Energy
  • "Energy Savers: Air Sealing [copy on file as /interiors/Energy_Savers_Air_Sealing_1.pdf ] - ", U.S. Department of Energy
  • Fiberglass: Indoor Air Quality Investigations: Health Concerns About Airborne Fiberglass: Fiberglass in Indoor Air from HVAC ducts, and Building Insulation
  • From the walls in, Charles Wing
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?InspectAPedia Bookstore (Amazon.com)
  • Insulate & Weatherize (Taunton's Build Like a Pro), Bruce Harley. Review quoted:
    An engineer who trains builders in energy-efficient construction, Harley offers a wealth of information that will allow readers to improve their home's efficiency, saving both money and natural resources. After an introductory section that explains the underlying principles of heat transfer, insulation, and air quality, Harley demonstrates basics such as weather-stripping and moves forward through advanced projects including insulation and major upgrades. Short "Pro Tips" as well as sections labeled "Trade Secrets," "What Can Go Wrong," and "In Detail" provide a great deal of helpful information. Increasing energy efficiency is one of the easiest ways for homeowners to save money
  • "Insulation: Adding Insulation to an Existing Home," U.S. Department of Energy - tips on how to do your own check for the presence of absence of insulation in a home
  • Insulation: Selecting Insulation for New Home Construction, U.S. Department of Energy - "Your state and local building codes probably include minimum insulation requirements, but to build an energy-efficient home, you may need or want to exceed them. For maximum energy efficiency, you should also consider the interaction between the insulation and other building components. This is called the whole-house systems design approach."
  • Insulation Types, table of common building insulation properties from U.S. DOE. Readers should see INSULATION R-Values & Properties our own table of insulation properties that includes links to articles describing each insulation material in more detail.
  • The National Institute of Standards and Technology, NIST (nee National Bureau of Standards NBS) is a US government agency - see www.nist.gov
    • "A Parametric Study of Wall Moisture Contents Using a Revised Variable Indoor Relative Humidity Version of the "Moist" Transient Heat and Moisture Transfer Model [copy on file as/interiors/MOIST_Model_NIST_b95074.pdf ] - ", George Tsongas, Doug Burch, Carolyn Roos, Malcom Cunningham; this paper describes software and the prediction of wall moisture contents. - PDF Document from NIS
  • Nogging: See this photo of exposed bricks on a building exterior on a building exterior in Canada. [Thanks to Carson Dunlop, Toronto - see References below].
  • Piquet Wall Construction: See this photo of piquet wall construction - involving timber-framed wall construction with long top girts, diagonal timber bracing, and small diameter logs placed vertically along with concrete chinking to fill in the wall plane.
  • Plank House Construction: weblog from plankhouse.wordpress.com/2009/01/25/plank-house-construction/ and where plank houses were built by native Americans, see
    Large 1:6 Scale Plank House Construction / P8094228, Photographer: Mike Meuser
    06/12/2007 documented at yurokplankhouse.com where scale model Museum quality Yurok Plank Houses are being sold to raise money for the Blue Creek - Ah Pah Traditional Yurok Village project.
  • Principles of Heating, Ventilating, And Air Conditioning: A textbook with Design Data Based on 2005 ASHRAE Handbook - Fundamentals, Harry J., Jr. Sauer, Ronald H. Howell, William J. Coad. Quoting
    ... textbook for college level HVAC courses or independent study and review, especially when combined with the 1997 ASHRAE Fundamentals Handbook. Contains the most current ASHRAE procedures and definitive, yet easy to understand, treatment of building HVAC systems -- from basic principles through design and operation. Dual units of measurement.
  • Re-Bath, tub lining products is a bath tub relining manufacturer and distributor located in Tempe, Arizona - see rebath.com
  • Rubblestone Wall Filler: See this Lartigue House using exterior-exposed rubblestone filler between vertical timbers of a post and beam-framed Canadian building.
  • Super-Insulated Retrofit Book: A Homeowner's Guide to Energy-Efficient Renovation, Robert Argue
  • The super-insulated retrofit book: A homeowner's guide to energy-efficient renovation (Sun builders series), Brian Marshall
  • Understanding Ventilation: How to Design, Select, and Install Residential Ventilation Systems, John Bower, Quoting:
    Understanding Ventilation is the only book that covers all aspects of exchanging the air in houses: infiltration, equipment selection, design, heat-recovery ventilators, sizing, costs, controls, whole-house filters, distribution, and possible problems that a ventilation system can cause--all in easy-to-understand language.
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • Weaver: Beaver Board and Upson Board: Beaver Board and Upson Board: History and Conservation of Early Wallboard, Shelby Weaver, APT Bulletin, Vol. 28, No. 2/3 (1997), pp. 71-78, Association for Preservation Technology International (APT), available online at JSTOR.
  • ...

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com