How to Measure & Correct Unwanted Building Heat Losses
Measure building heat loss: This article explains how to insulate a building and how much insulation is needed including how to measure or calculate heat loss in a building.
We define heating, coolilng and thermal terms like BTU and calorie, and we provide measures of heat transmission in or through materials, We give desired building insulation design data, and shows how to calculate the heat loss in a building with R values or U values.
Discussed here: How to Measure or Calculate & Stop Building Heat Loss. Find Drafts, Measure Insulation Values & Find Heating Cost Savings.
How to measure heat movement through a wall. How to measure building insulation.
How leaky is the building. Building design temperatures & how to use a home energy audit or heat loss analysis. What insulation "R" values should be used in a building insulation?
Our page top photo illustrates the importance of a visual inspection of all building areas: voids where insulation has fallen out of a cold crawl space floor can make a significant differnece in building energy costs as well as comfort.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
A detailed presentation of heat loss and R-value
Formula-R™ and Owens Corning™ which may be visible in this photograph of pink Styrofoam™ insulation boards are registered trademarks of Owens Corning® and were photographed at a Home Depot® building supply center.
When we are evaluating the quality and effectiveness of insulation in a building or the adequacy of a building heating or cooling system, we need to use measurements that permit us to describe the rate at which a building loses heat under various conditions (such as outdoor temperature, wind velocity, how leaky the building is, the area of its windows and perhaps doors, and the amount of insulation in the building walls, floors, and ceilings.
A few of these critical definitions for heat loss and insulation values are given just below, followed by some simple formulas used to calculate the heat loss in a building and formulas for calculating R-values.
Definition of BTUs and BTUH: a BTU is one "British Thermal Unit" which is defined as the quantity of heat that would be required to increase the temperature of one pound of water by one degree Fahrenheit.
A BTUH is defined as the number of BTU's lost (if we're talking about heat loss or air conditioning), or provided (if we're talking about providing heat for a building) in one hour. You'll often see BTUH as a number on data plates on air conditioners and on heating systems.
One BTU is also equal to 252 calories. So what's a calorie?
Definition of Calorie or Calories: a calorie is defined as the quantity of heat needed to raise the temperature of one gram of water by one degree Centigrade.
How do we measure and express how well a building is insulated? or How much heat loss is occurring at a specific building?
Many people have heard of using "R" values to describe "how good" a building's insulation is. This article explains three measures of the flow of heat out of or into a building: R-values, K-values, and U-values. Each of these is defined below. But before moving on to these basic concepts of building heat loss (or gain) theory, it is essential that this still more basic point be considered:
It doesn't matter much how wonderful the building insulation is, how thick it is, or what the insulating material's "R" value is (see R defined below) if the building is leaky.
If, for example, we're considering an older home with leaky windows or doors, or if we're considering a tall building with poorly controlled heat in winter, such that occupants of the upper floors are leaving windows open in winter then the heat flow out of these openings will be so terrific that the amount of insulation won't matter much.
For details about actual heat loss calculations see HEAT LOSS R U & K VALUE CALCULATION. Continue reading this article series with the links shown just below.
Details about this topic are at ENERGY SAVINGS PRIORITIES. Excerpts are just below.
Therefore when the object is to make a building more energy efficient, and before any more sophisticated analyses are performed using thermography, insulation evaluations, or even calculations of areas, "R" values, "K" values, or "U" values (defined below), remember this order of concerns when working for building efficiency. The order of magnitude of sources of un-wanted heat loss in a building are pretty much in this order:
This article has been relocated to RADIANT HEAT FLOOR MISTAKES where we describe installation specifications for radiant heat flooring in a poured concrete slab along with a detailed report of just how bad a radiant heat floor slab installation can be. The article's conclusions include this insulation advice:
Luckily, after having already discussed "K" values, "U" values, and "R" values as measures of heat loss just above, calculating a building's actual rate of heat loss is pretty simple - it's a "cookbook" process that uses the following formula:
Calculating the Building Heat Loss Rate using "R" values:
(Building Heat Loss in BTU's per hour) =
[(Building Total Surface Area in sq.ft.) / (Surface Area "R" value)] x (Temperature Difference)
Temperature Difference = the difference in temperature in deg F. on the two sides of the building surface, typically indoors and outdoors
Surface Area "R" value = the "R" value of the surface area being evaluated (say an insulated wall).
Calculating the Building Heat Loss Rate using "U" values:
(Building Heat Loss in BTU's per hour) U = 1/R, - or in other words -
(Building Total Surface Area in sq.ft.) x (Surface Area "U" value) x (Temperature Difference)
Thanks to Steven Muscato for correcting this formula.
But there's more work to do for a complete answer to building heat loss. We need to make up a simple table which will contain the total surface area of each type of material (since each will have it's own "R" value) and then plug in the area's "R" value and the temperature difference.
Usually we assume the same temperature difference for all of the areas of the building though this might be a simplification since that may not be exactly true.
We're also missing, from this simple calculation, the effects of wind on a building's heat loss, though a more sophisticated version of this approach might simply adjust the temperature difference to include
the wind factor. For example, you could use a wind/temperature chart to derive the effective outdoor temperature when it's also windy.
[Click to enlarge any image] Shown here: a minus 30°F wind chill report for Two Harbors Minnesota in early February 2018.
In cold conditions, adding a wind velocity might increase the temperature difference across the building wall at least for the sides of the building against which there is significant wind-driven air movement.
Really? Well not necessarily. The effects of wind on the rate of building heat loss might be complex. For example if wind is pressurizing the air around all or part of a building that pressure might counteract the heat loss from air leakage from the building due to convection or buoyance or the stack effect that is usually described by warm air rising through the structure to pressurize and escape from air leaks present in pper building areas.
While you cannot directly use wind chill as a measure of heat loss from a building surface, you can find current wind speeds in local weather and wind data.
More sophistication of measures of heat loss are possible by adding the [wind chill] effects of moisture on heat loss from a surface, but while this is important for a (sweaty) human in cold conditions it is generally ignored when considering building heat loss.
Special thanks to reader Mike Kerry for discussing this topic, 2018/02/15. See details at HEAT LOSS in BUILDINGS, WIND EFFECTS below.
This is a perfect application for an Excel or similar spread sheet, listing each building surface type (wall, window, door), it's R, K, or U value, and its total area. Adding temperature difference across these surfaces permits a calculation of the heat loss (or gain) through each surface type. These are simply added together to represent the entire building's heat loss or gain.
You may have noticed we keep talking about heat loss and then we add "or heat gain" in the same sentences or headings.
That's because heat loss analysis works just fine for both building heating and building cooling.
The only differences between looking at heat loss and heat gain for a building are the direction of heat flow and the fact that we may be using different equipment with different equipment efficiencies (a heating furnace or boiler versus an air conditioner).
If we're in a heating climate and are in the heating season, heat will flow from the building interior to the outdoors.
If we're in a cooling climate and are in the cooling season, heat will flow from the outdoors to the building interior. Just remember that (according to the laws of thermodynamics), heat (or energy) always flows from the warmer (or more exited state) into the cooler (or less excited state) area of a building.
A less precise and less computerized method for calculating building heat loss (or gain) is used by people who perform an "energy survey" or energy audit for a building. Home energy audit services may be free from your local utility company. The energy survey technician uses a pre-printed form whereon s/he records the areas of the building's walls, top floor ceilings, foundation walls, floors, and the number and type of windows and doors.
An "R" value is assigned to these and the sheet is used to manually calculate the building's rate of heat loss. We had one of these "free" surveys performed on a home built in 1900 when we were renovating it years ago. Regrettably the surveyor was not very observant. He rated our walls at a very high rate of heat loss by assuming that they were not insulated whatsoever (and then proceeded to try to sell us an insulation service).
What that particular home energy audit surveyor failed to notice was that the building walls had been insulated (with blown-in foam) - a condition that was quite easy to see since we had removed the building's exterior siding and wall sheathing. He just didn't look.
So while home energy audits are a great idea, make sure your auditor is awake before you believe the results of the home energy survey. And remember that some "home energy auditors" are really trying to sell you replacement windows (very long payback time) or building insulation. (Remember the urban legend about the home energy auditor who was using a camera light meter as an "energy loss" indicator to convince home owners that they needed new windows?)
Home energy loss surveys using thermography or simple infra-red thermometers are a great way to pinpoint individual points of heat loss (or unwanted heat gain) in a building. In the hands of a properly-trained expert (not a window salesman) this equipment can help find unexpected building air leaks or heat loss points even when you think that the building has already been insulated.
Having a "high-R" insulated wall or ceiling is not going to be enough to make a building energy efficient if there are many unidentified air leaks or insulation voids in the building's walls, ceilings, or floors.
The "indoor design temperature" for a building refers to the assumed target indoor temperature that the building owner or occupants want. Typically 70 deg.F. is used unless the owner specifies something different.
The "outdoor design temperature" for a building is (for heating purposes) assumed to be the average lowest recorded temperature for each month between October and March (the heating season in most climates). If we are specifying a "design temperature" for cooling climates we'd use the average outdoor highest recorded temperature during the heating season, perhaps April through September.
Some building insulation designers and architects look at the number of "degree days" as an easy way to get at the average outdoor temperatures for an area and a season. A Degree Day is the daily average number of degrees Fahrenheit that the outdoor temperature is below 65 deg.F.
The number of "degree days" during a heating season is easy to obtain: call your local oil delivery company or utility company. These energy providers keep close tabs on degree days for their area since this number is used in planning for the automatic delivery of energy.
It's the number of "degree days" that have occurred in a given period, combined with a building's historic rate of heating oil use, for example, that tells an oil company when to schedule that building for an automatic delivery of heating oil.
"One ton" of cooling capacity, historically, referred to the cooling capacity of a ton of ice. One ton of cooling capacity is the same as 12,000 BTU's/hour of cooling capacity.
Tons of ice does not, however, explain an important factor in the comfort produced by air conditioning systems, reduction of indoor humidity - that is, removing water from indoor air. Cool air holds less water (in the form of water molecules or gaseous form of H2O) than warm air.
Think of the warmer air as having more space between the gas molecules for the water molecules to remain suspended. When we cool the air, we in effect are squeezing the water molecules out of the air. When an air conditioner blows warm humid building air across an evaporator coil in the air handler unit, it is not only cooling the air, it is removing water from that air.
Both of these effects, cooler air and drier air, increase the comfort for building occupants. One ton of cooling capacity equals 12,000 BTU's/hour of cooling capacity.
BASEMENT CEILING VAPOR BARRIER
ENERGY AUDIT - How to Use a Free One
ENERGY SAVINGS MAXIMIZE RETURNS ON
U-value, K-value calculations are at HEAT LOSS R U & K VALUE CALCULATION.
And if you are not sure of the definitions of R, U, & K Values see DEFINITION of HEATING, COOLING & INSULATION TERMS. Also see INSULATION R-VALUES & PROPERTIES where we present a table of different insulating materials and their R-values and properties.
Because no amount of insulation can keep a drafty building warm, also review ENERGY SAVINGS PRIORITIES.
The blower door test shown at left is discussed in detail at HEAT LOSS DETECTION TOOLS.
2018/02/15 Mike Kerry
The article states "Use any 'wind chill factor' chart for this data." This is incorrect. Most published WCF formulae and tables are applicable to human skin, not buildings.
Thank you Mike, that's a very important point that I will clarify in the article above.
I would very much appreciate any research citations you can offer to improve our discussion of this point.
Below I include what I've learned.
I agree that wind-chill as an effect on humans takes other factors such as relative humidity (RH) into consideration, while RH may have a different effect on the rate of heat loss increase as windspeeds increase around a building.
Research confirms that wind effect on the rate of heat loss at buildings is important, but I agree that using a human-skin "wind chill" number is not directly useful. Experts like Palyvos (2008) do suggest, however, that one can extrapolate usefully from common and widely-available measurements of winds.
Sharples points out that you need to look at wind speeds as measured close to the actual building's surfaces. To which I'd add that for a given overall wide-area wind speed, those data will be very different at different building sides and in different terrains.
It may also be important to consider the effects of wind pressure on a building's heat loss due to the stack effect. (Li 2001).
...
Continue reading at HEAT LOSS DETECTION TOOLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
HEAT LOSS in BUILDINGS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about building heat loss: causes, detection, cures.
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.