Water Tank Leak Diagnosis & Repair FAQsRecent water pressure tank or water storage tank air leak or water leak diagnosis & repair FAQs.
This article series describes how and why to diagnose problems right at the water tank in order to help distinguish among intermittent water pressure loss, total water pressure loss, and poor water pressure or flow in a building.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
The questions & answers about water tank leaks were posted originally
at WATER TANK DIAGNOSIS & REPAIR - topic home. Please be sure to see the diganosis and repair advice given there.
Also see WATER TANK BLADDER DIAGNOSE, REPAIR or REPLACE questions & answers about diagnosing and fixing water pressure tank leaks and tank bladder leaks or other problems.
...
I have a well the water is back on after the frozen lines defrosted but water is coming out of the pipe ! By the pump ! Looks like a leak ! No pressure on gauge! Should I turn off the pump?
SOS: my wayer froze and now is working but water is coming out of pipe by the big blue water tank the gauge says I have zero pressure should I turn off the power to the pump !
The pipe froze now water is running and leaking out of pipe by the water pump and no pressure on gauge should I turn pump off!
It on that T-joint , it’s a pin hole leak ! I can either spray flex seal on it or replace the t joint with a handle turn on it! Thanks for helping me picture attached
It’s leaking a pin hole of water on the t joint in the picture attached!
I figure I can spray it with flex seal or get the piece replaced with a different type of t joint with a handle to turn water on & off! It on the side faceing me! On 2018-01-09 by Becca -
Suggestions by (mod) - To repair a leak in the water tank tee
Becca
With the pump OFF, if there is a leak anywhere in the system water will continue to leak until the system pressure is down to about zero.
I see water on the ground but not where the leak is occurring.
I see at the left side of the tank water piping what looks like a foam insulated water line connected using a stainless steel hose clamp that can be tightened using a screwdriver.If you have a leak there, try tightening that clamp.
Tell me where you see water leaking.See PIPE / HOSE CLAMP LEAK REPAIR
Bottom line: if the leak really is at the tank tee itself, I'd prefer to have that part replaced. I wouldn't want to trust the topically applied sealant to prevent a new leak, perhaps worse, if no one is at home to catch the problem.
But in your photos I see several threaded fittings, at least one of which shows corrosion and may be the actual leak point - at that shutoff valve. I'll have added yellow pointers to the suspect connections where there may be leaks.
The three yellow arrows point to obvious and common leak points and the yellow lines point to five additional places to check carefully for leaks.
Watch out: among these, the most dangerous indicator might be leaks at the outlet of that pressure relief valve - the bottom yellow arrow.
The two arrows point to apparent leak points at that shutoff valve. The leftmost arrow is pointing to corrosion - a likely confirmation that there has been leakage at this point. - Daniel
by Becca
Yep I returned the flex seal you can’t use for that ! Got the part to replace it! Waiting on someone that can do it ! Tnx all!
Picture of part ! The people have a pipe wrench so I better wait for them to do it ! Tnx again!
by (mod) - replace water shutoff that is leaking through brass body
That's a brass bodied ball valve shutoff - nice going. A pinhole leak can be caused by
- freezing and cracking of the valve body
- corrosive water (that also will threaten copper pipes and lead to more pinhole leaks)
- mechanical damage
- or a leak at the valve connections mistaken for a leak in the valve body
I would replace the part, thus making a more reliable repair than a coating could provide.
...
Tip: See CONDENSATION or SWEATING PIPES, TANKS
I can not find where I have a water leak, but every time we run water upstairs we have a little puddle of water near our water storage tank. If we do not run water there is no puddle.
But I do not see the leak.
Could I have a leak in the bladder that goes into the tank and when the bladder is filling it pushes out a small amount of water?
If we run a lot of water we get more water near tank. Advice please On 2018-07-08 by Edward McKeown
Diagnostic suggestion by (mod) - check first for condensation on the water tank
Edward
Perhaps it's not a leak but condensate dripping off of a cold water pipe or off of a water pressure tank that's collecting moisture from the air?Try using a dry towel to wipe off everything that's wet: the water tank, pipes, valves, etc. at the water tank.
Then watch closely to see where water first appears. If it's condensation on the tank that may be the puddle source.
If however you see water dripping at a control valve or relief valve or pipe connection that'll be the repair point. - DF
...

WR-60r well rite diaphram water tank leaks water from the bottom. Can this be repaired (Dec 31, 2014) Anonymous
Reply: Unless the leak is at a repairable plumbing connection, or the tank has a replaceable bladder, replace the tanki
Temporary patches using a screw and neoprene washer or epoxy are just that: temporary and usually not long-term reliable.
Your Well-Rite 60-R is a 20 gallon water pressure tank from Flexcon, sold widely at plumbing suppliers and building suppy stores.
It uses an internal bladder that is not considered economically replaceable so even if the leak is at the tank bottom bladder access port or even if the leak is traced to a bladder failure, repair still isn't recommended.
I'd replace the tank unless the leak is at a threaded plumbing fitting that can be re-made. A matching WR-50R water tank retails (in 2026) for $500 to $650. - Daniel
Hi I have a leaking pressure tank at the fitting at the bottom. There is a boost pump plumed into the wet side of the tank.
I checked the schrodier valve near the gauge at the top and water does come out of it.
Does this tank need replacing?
Please see the attached picture. 2020-08-12 by Bill -
by (mod) -
Bill
A leak at the tank bottom would be from a defective piping connection OR it could just be condensation; let's start diagnosing that leak by wiping the tank dry and watching it closely to see exactly where the leak occurs. Otherwise any repair advice anyone might give is too speculative to be very helpfu.
If water comes out of the air valve (Schrader valve) at the top of a water pressure tank AND if the tank uses an internal bladder, then the bladder has leaked - and failed.
But your tank may not use an internal bladder. Rather it's simply waterlogged. That would explain why opening the air vent or Schrader valve mounted on that gauge tee at the top of your water pressure tank squirts just water, no air.
Watch out: what's that little pump mounted on the wall above and to the right of the water tank. It looks like a pump intended to serve as an injector pump system to add disinfectant to a water supply system, but only 1 of the two tubes is attached to the little pump.
The second tube that would bring disinfectant to the pump has been disconnected.
Also I notice that the wiring to your pressure control switch is unsafe: missing a strain relief at the switch side and missing the switch cover - shock hazards.
Can a hole in the tank be repaired On 2017-02-16 by Karen squires
by (mod) -
Karen,
As long as we are talking about a steel water tank that does not use an internal bladder, a hole in a water tank might be repairable, depending on the overall condition of the tank and the extent of rust that you cannot-see: on the inside of the tank wall.
In WATER TANK REPAIR PROCEDURESMy photo at the top of this article shows a type of tank repair screw and washer. A screw size is selected to accommodate the diameter of the hole in the tank and is screwed in place; its washer seals the leak by pressing against the tank's outside surface.
Beware that because corrosion is on the inside of the tank the tank wall will be thinner around the point of leakage than you might think, so you might need a larger screw than you might guess.So buy several sizes so that if on installation the first screw leaks because it's too small you can try a larger one.
There are also metal expoxy sealants that can work if the tank surface is clean and dry, though I prefer a mechanical seal.
Beware that a water tank that has perforated is probably at or near the end of its life and that other leaks may appear soon.
Finally, you might want to have your water tested for corrosivity, as if it's corrosivity index is high your building plumbing is also at risk and you might want to install an appropriate water treatment system. The corrosivity of water is discussed at CORROSIVITY or ACIDITY of WATER https://inspectapedia.com/plumbing/Acidic_Corrosive_Water.php
by (mod) - SOME bladder-type water pressure tanks are designed to permit bladder replacement.
Kevin,
SOME bladder-type water pressure tanks are designed to permit bladder replacement.Those tanks will have a removable panel, usually on the tank bottom. If your water tank is one of those you'd buy a replacement bladder assembly from your local plumbing supplier or if necessary through the water tank manufacturer.
You can check with the manufacturer or in your water tank's installation and maintenance manual for the replaceable-bladder feature once you know the water tank brand and model.
My pressure tank has a very small pin hole . Can the pressure tank be welded or sealed in anyway , or will the tank need replaced completely ? - Tom A. 8/11/11
Reply:
Yes, Tom. At your local hardware store you can probably purchase a special screw and washer part (less than $5.00. U.S.) intended to temporarily fix pinholes in water pressure tanks.
Watch out though: often a pinhole on the exterior wall of the tank will be found to be a bigger hole when you start messing with it- because the tank is corroding from the inside (usually) the area of thin walled steel may be bigger than you think. Buy several repair screws of varying size and start with a small one to see if that can screw in tightly enough to stop the leak. If it won't, you'll need to use a larger screw.
Welding is technically possible but not economical, and a repair epoxy might work with good surface cleaning provided you could take the tank out of service long enough and keep it dry during the gluing process, but like the little DUtch boy with a finger in the surface of the dike, that's not the most reliable repair.
Figure a new water tank is in your future
Can a hole in the tank be repaired? 2017-02-16 by Karen Squires
Answer by (mod) -
Karen,
As long as we are talking about a steel water tank that does not use an internal bladder, a hole in a water tank might be repairable, depending on the overall condition of the tank and the extent of rust that you cannot-see: on the inside of the tank wall.
In WATER TANK REPAIR PROCEDURESMy photo at the top of this article shows a type of tank repair screw and washer. A screw size is selected to accommodate the diameter of the hole in the tank and is screwed in place; its washer seals the leak by pressing against the tank's outside surface.
Beware that because corrosion is on the inside of the tank the tank wall will be thinner around the point of leakage than you might think, so you might need a larger screw than you might guess.So buy several sizes so that if on installation the first screw leaks because it's too small you can try a larger one.
There are also metal expoxy sealants that can work if the tank surface is clean and dry, though I prefer a mechanical seal.
Beware that a water tank that has perforated is probably at or near the end of its life and that other leaks may appear soon.
Finally, you might want to have your water tested for corrosivity, as if it's corrosivity index is high your building plumbing is also at risk and you might want to install an appropriate water treatment system.The corrosivity of water is discussed at CORROSIVITY or ACIDITY of WATER
...
Continue reading at WATER TANK REPAIR PROCEDURES - or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see this WATER TANK INSTALL, DIAGNOSE, REPAIR FAQs INDEX - our index to all questions & answers about diagnosing and fixing water pressure tank problems.
Or see these
WATER TANK LEAK DIAGNOSIS & REPAIR FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.