Bestwall or Beaver Wallboard Asbestos FAQs

Q&A on Asbestos Content in Beaver / Bestwall Products

Q&A on the presence of asbestos in Beaver or Bestwall wallboard plaster board products.

Page top photo: the edge tape on this plasterboard (gypsum board) identifies it as G/P BESTWALL - which enables us to set a date or possible wallboard age as well as to consider the asbestos question.

This article series explains where asbestos is likely to be found in gypsum board or drywall systems, particularly in the taping compound and in skim coats using drywall "mud" that contained asbestos.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

Bestwall Gypsum Board Asbestos Content Q&A

These questions and answers about drywall asbestos were posted originally

at BESTWALL DRYWALL ASBESTOS - be sure to check out the diagnostic suggestions on that page.

Need help deciding if our Beaver BESTWALL wallboard contain asbestos.

We just removed some wall boards from a room in my house. We have lived here for 16 years, never replaced any wall boards and just found the beaver bestboard logo on the back ... Bestwall Form 1789.

I cannot find a us patent number. I need help.

We will be be wearing masks from here on out but I cannot say we, as a family won't have issues in the future.

I have included a photo from the back of one of the boards.

Thank you.

On 2022-07-20 by Laurel E Greene

Reply by InspectApedia-911 (mod)

@Laurel E Greene,

Thank you for the Bestwall drywall label photo.

Our most complete information about this topic and therefore your question are found in the article above.

I'm seeing just a photo of the label; I don't think we can say more about this product (than we do on this page)

But it would be helpful to know the location of the building where this Bestwall plasterboard is installed and the age of the building

Please take a look at the description of Bestwall and the asbestos question discussed at BESTWALL DRYWALL ASBESTOS and let me know if any of that leaves you with a question.

by Laurel Greene

@InspectApedia-911, My home was built in 1925, this is installed in a bedroom. We are located in Northern Florida.

by InspectApedia-911 (mod) - BestWall Bankruptcy Filing includes Asbestos-related documentation

@Laurel Greene,

Thank you that's very helpful with respect to establishing the history of the use of Bestwall plasterboard.

FYI there was another "1789" in a Bestwall court docket re: Bestwall LLC, Chapter 11 (bankruptcy filing) , Case #: 17-31795, Court: United States Bankruptcy Court, Western District of North Carolina, Charlotte Division,Judge The Honorable Laura T. Beyer, filed November 2, 2017.

BestWall was facing more than 62,000 asbestos-related lawsuits when the company filed for bankruptcy in North Carolina in 2017.

  • Western District of North Carolina, Charlotte Division, Case #: 17-31795, Affidavit of Service (RE: related document(s)1776 Other Document filed by Debtor Bestwall LLC) filed by Garland S. Cassada on behalf of Bestwall LLC. (Cassada, Garland) (Entered: 05/05/2021)

The documentation for this case, in a collection hosted by this law firm: Donlin Recano, (Equiniti) https://www.donlinrecano.com/Clients/bw/Dockets, includes other affadavits that involve asbestos claims and Bestwall.

That doesn't tell us if your particular Bestwall was an asbestos-containing gypsum board.

Some, but not all, BestWall products contained asbestos as we describe above on this page. .


How do I Identify this Wallboard and Does It Contain Asbestos?

I started a remodel about a year ago and haven't done much drywall work other than remove some panels in a bathroom. But I got more into it and started removing panels in a closet.

Georgia Pacific Bestwall in Palm Beach, FL remodel (C) Inspectapedia Midremodel

I finally was able to get a manufacturer and a code but nothing seams to come up for the code and not much is said about this product. Its made by georgia pacific at the end of the paper is says G-P/BESTWALL

Can someone help identify this board of when it could have been manufactured. I can send more images

On 2022-02-02 by Midremodel

@Inspectapedia Com Moderator, its in USA palm beach Florida built in 1975

by Inspectapedia Com Moderator - Yours is Georgia Pacific Bestwall Drywall = 1965 or later.

@Midremodel,

Thank you that identification photo will help other readers spot their Bestwall made by Georgia Pacific.

From your building date you would follow the advice we gave earlier: treat the drywall as presumed to contain asbestos - avoid making a dusty mess.

From the topic home page

at BESTWALL DRYWALL ASBESTOS

we note that Georgia Pacific purchased the BestwalL Gypsum Co. from Certainteed in 1965.

So your drywall can date from 1965 or later.

It would be helpful to know the country and city of the building you're remodeling and the age of the building itself.

Yes it would be helpful too to see sharp photos of the end tapes or other printed matter found on the edges or back of the drywall beyond the date code you include and the bit of tape indicating G-P / Bestwall.

If the intent of your question was to ask if your drywall contains asbestos, from the article above we also note

Drywall systems that may contain asbestos - at least in finishes, taping joint compounds, skim coats, or in systems that applied plaster over gypsum board date from about 1910 through the early 1980's in North America (1982 in Canada).

So you would treat this drywall AND the joint compound used in its finishing as presumed to contain asbestos, OR have representative samples tested for asbestos.

by Midremodel

@Inspectapedia Com Moderator, based on the wording on the label it looks more modern than previous photos submitted. I have been searching all over but there isn't much information out there.

I purchased 6 tests to be able to get different types of material for testing. If anyone has any info I would appreciate it.

by Inspectapedia Com Moderator

@Midremodel,

True but our earlier photos on this page are mostly pre the G-P purchase.

Often when remodeling a home it is patently easy to determine if drywall that you remove is the original. If you pull a section of drywall of of what is clearly an original wall of the building, look at the location of the drywall screws (or more likely nails in older homes) - and note their location on the wall studs. Then look on the studs for holes or remains of nails from an older generation of drywall.

If there is only one layer of drywall found on a surface (usually the case), and

If the only marks on the wall studs (or ceiling joists) where drywall has been removed are from the fasteners used to hang the very drywall just pulled down, then you can be reasonably confident that that drywall dates from original construction of that wall or ceiling.

Post a photo of an exposed stud or joist if you find what you suspect are marks from an earlier wall covering that was removed.

I encourage you to go ahead with testing for asbestos; be sure that your samples include both the drywall itself - sampled from a central area not skimmed with joint compound, and a second sample of the joint compound used at drywall butt joints and perhaps at a wall/ceiling juncture.

Do let me know what you find as that will be very valuable to other readers.

On 2022-02-02 by Midremodel

@Midremodel, this is what they used to mend the boards together. Yellow mesh tape. I looked this up and I'm not sure how accurate the info is but mesh tape was brought to market during the 80s. Can anyone confirm this?

On 2022-02-02 by Midremodel

@Midremodel, found another piece of label part of the same board, and an undisturbed piece of gypsum board.

Above: the wallboard edge tape identifies this as G-P/BESTWALL - a Georgia Pacific product.

by Midremodel - More Bestwall Wallboard ID Photos

@Inspectapedia Com Moderator, Took a bunch of pictures to illustrate what I have going on.

This is the studs. And what the board looks like. Screws on bottom to top about 7' the rest of the way is nails.

by Inspectapedia Com Moderator

@Midremodel,

I'm not sure about those holes in the side of the stud, but the ones in the face + observation that your latest drywall was installed with screws all MIGHT argue that it's not the first generation of wall covering in that home.

Drywall screws were introduced in the U.S. as early as the 1950s - but in my OPINION were not in common / widespread use until the 1970s and later.

" In the 1950s, Illinois fire-protection engineer Paul Quigg and a team of co-workers at the U.S. Gypsum Corp. perfected the drywall screw.' - JLC Online at https://www.jlconline.com/how-to/a-short-history-of-screws_o#:~:text=In%20the%201950s%2C%20Illinois%20fire,perfected%20the%20drywall%20screw. - a short history of screws.

by Midremodel

@Inspectapedia Com Moderator, there's lots of ASTM C36 but the earliest I could find was 1980s does the ASTM test for asbestos?

The holes on the side are for the other piece of drywall that use to be there.

by Inspectapedia Com Moderator

@Midremodel,

No. Asbestos testing is performed by an independent certified asbestos test lab. The experts directory found at the top of any of these Pages you'll find a leg to asbestos test labs.

We're in agreement that there are at least two generations of drywall it appeared to have been mounted on those studs


Risk of asbestos in Bestwall wallboard in a Missouri 1940s home?

I’ve been curious for sometime around the walls in my 1940’s build home since there is no lath. I’m in Ironwood, MI. I took possession of the home a little over a year ago and started renovations right away.

I finally did a search on my walls and came to this site (thank you!). I’m concerned I have asbestos walls given the fire proofing mark on the Beaver Gypsom Lath product. Also marked is “certain teed”. Appreciate your thoughts on this. On 2022-01-10 by lulutalulu

by Inspectapedia Com Moderator

@lulutalulu,

Certainteed purchased Beaver Products in 1928. So finding a Certain-Teed gypsum lath board in a 1940s Michigan home is not surprising. It's "Fireproof" label hints at a likely use of asbestos.

This is a gypsum based product, not the wood fiber board products also bearing the "Beaver" name and also discussed

at BEAVERBOARD IDENTIFICATION

where we repeat your question and photos and give a detailed reply.


Identify this Gypsum Wallboard - same patent No. as drywall tested and found negative for asbestos - is that a "no asbestos" guarantee?

Bestwall drywall stamped as fiberglass reinforced, made ca 1961 (C) InspectApedia.com ErinThanks so much because I've been constantly cleaning the dust in the living area and kitchen is worse and seems neverending. I'm wearing a n95 mask to be safe and damp wiping everything and I have a dyson vaccume that has a hepa filter that i also have been using but I'm still very anxious.

I'm glad there's no asbestos but fiberglass is not much better but I'm glad to know this information as it helps ease my anxiety. Thanks again I appreciate it.

The drywall in my photo has the same patent # as the drywall your reader had tested negative for asbestos. Since it has the same patent number does this mean this one also has no asbestos?

I read a few posts about this same patent number also stating it does not contain asbestos I'm worried though because we are renovating and tore down a wall that connects our kitchen to a carport that we are turning into another room.

The area was closed off the with tarp but the still the dust is everywhere. Just want to be sure

Could you please tell me if this is the same drywall that the reader tested negative for asbestos in the above photos as it has the same patent number.

I'm trying to find out for sure because we are making an addition out of our carport and this weekend tore down a wall to open up our kitchen to the addition and it had drywall with this same patent number.
Thanks On 2021-08-23 by Erin

by inspectapedia.com.moderator (mod) - No; Fiberglass in gypsum board / wallboard from Bestwall ? Consider the joint compound too.

@Erin,

Bestwall drywall stamped as fiberglass reinforced, made ca 1961 (C) InspectApedia.com Erin

Your drywall stamp says it contains fiberglass - so it's not so likely to also contain asbestos.

But as you'll read in the article above, this topic is confounded: some drywall, plaster, gypsum board patents such as by Croce in the 1950s refer, in the patent disclosure, to using asbestos, and at least one Croce patent specifically refers to mixing both fiberglass and asbestos.

Just removing drywall sections essentially intact with minimal dust production is not likely to produce a significant dust hazard, but in all cases it'd make sense to use appropriate careful dust control and cleanup such as HEPA vacuuming.

It would be really helpful to know the country, city, and age of the building where such products are found.

by Erin - does this patent number assure me of no asbestos in Bestwall drywall?

@inspectapedia.com.moderator,

So could you tell me since my drywall has the same patent number as the anonymous reader from Philadelphia who posted 2 photos of drywall with the same patent number back in 8/2020 and he tested it and came back negative does that mean the same for the one I'm questioning since it has the same exact patent number? I just want to be sure I understand correctly.

Thanks the Patent of the drywall that was removed has the same exact patent as the reader who posted above #2681613 and it tested negative for asbestos would that also mean the same for this one?

Home was built in 1961
Maryland USA

by inspectapedia.com.moderator (mod) - No

@Erin,

Apologies, I was a bit uncertain myself in earlier replies so got a bit weasel-mouthed.

Bottom line:

Your drywall has a prominent stamp emphasizing that it is a fiberglass-reinforced product.

My best guess is that there is no asbestos in that drywall ; my thought is that when the manufacturers went to a prominent "Fiberglass" stamp it was in recognition that many consumers were worried about buying a product that might have contained asbestos - as some drywall did previously, particularly fire-rated products.

But I don't have and I suspect we'll not get an unequivocal promise from any drywall manufacturer nor anybody else that a product of unknown age is asbestos free.

That's why it's useful to take two more steps:

1. identify the age of your drywall: if it's from original construction, find out when your building was constructed, and where.

Yours is a U.S. building in Maryland built in 1961.

So in a U.S. home asbestos was occasionally found in drywall up to about 1986 but my prior advice is our best; plainly labeled as "fiberglass reinforced" your drywall is not likely to contain asbestos, but asbestos could have been in the joint compound as we mentioned earlier.

If we know that we can apply common "asbestos-last-used" date. For example in the U.S. that'd be 1986.

2. Consider that not just drywall, but drywall joint compound, used at every taped joint and often at other smaller repair spots, contained asbestos as well, up to the same cut-off date.

For example, if your home was constructed in 1980 and used a drywall product that is labelled as "fiberglass reinforced" and so is not at all likely to contain asbestos, nevertheless, the joint compound that was used in the installation might itself have contained asbestos.

Finally,

Do not panic about this question; the panic may be a worse health hazard (and financial hazard) than the drywall.

Asbestos-containing materials are safe and legal to leave in place as long as they're un-damaged.

And where large sheets of drywall are removed basically intact with minimal dust creation the remaining dust hazards should be trivial: easily cleaned up with HEPA vacuuming and damp wiping.

by Erin - What is joint compound or "drywall mud"?

@inspectapedia.com.moderator,
One more question what is joint compound?

Ok thank you so much for your input
I appreciate it On 2021-08-24 y Erin

by inspectapedia.com.moderator (mod) -

@Erin,

Joint compound or "mud" as it's called in the drywall trades, is a thick white pasty mixture of gypsum and water that is used, usually along with paper or mesh tape, to conceal the joints in drywall-covered ceilings and walls.

Joint compound is troweled onto the joints, covered with paper or mesh tape, and one or two top coats of compound are added; when dry that finish treatment is sanded so that the walls and the joints of wall-to-ceiling are smooth and ready for painting.

@Erin, in th photo below, the white stripes you see on the wall are joints (and drywall mounting screws) that have been covered with joint compound or "drywall mud".

See details at

ASBESTOS-DRYWALL REMEDIATION / REMOVAL

Horizontal drywall runs (C) D Friedman Eric Galow

 

Does this Beaver™ BestWall Drywall contain Asbestos? How do I remove it?

Beaver BestWall plasterboard asbestos (C) InspectApedia.com Dave2020/04/14 Dave said:

Doing some remodeling and wondering if this drywall has asbestos in it.

And what what is the best way to remove. Thanks keune_2007@hotmail.com

Moderator reply: maybe not

Dave,

Thank you for the BestWall photo and asbestos question. You'll find your question, photo, and my answer in detail now in the bottom of the article above.

Beaver - or BeaverBoard - as an original product, was a wood fiber, non-asbestos product that we discuss separately

at BEAVERBOARD IDENTIFICATION

But your Beaver - BestWall specifically is identified as a plaster wall-board.

So please take a closer look at the EDGES of your Beaver BestWall product.

If you see plaster or gypsum then treat the wallboard itself, as well as its plaster-coating as asbestos-suspect or asbestos-containing.

If your Beaver BestWall is pure brown fiberboard, then see details about the product at the BEAVERBOARD article I cited just above.

Asbestos in your Bestwall Drywall is a definite risk, as you'll read in the article above on this page. Here is one excerpt:

Bestwall LLC, facing over 64,000 asbestos injury claims, filed for Chapter 11 bankruptcy in the U.S. Bankruptcy Court, Western District of North Carolina, Charlotte Division, on 2 November 2017. Case No. 17-31795.

You'll want to minimize dust during removal: remove largest possible pieces of drywall, without cutting with power tools, wetting or dampening dusty or damaged areas, and using a HEPA rated vacuum cleaner for dust clean-up, followed by damp-wiping.

Use appropriate personal protection equipment (PPE) including a HEPA-rated respirator; I prefer not to rely on a simple paper N-95 dust mask and during the current COVID pandemic, expected to end no-time soon, N-95 masks are in short supply.

Please see details on how to remove asbestos-containing drywall or asbestos-suspect drywall

at ASBESTOS-DRYWALL REMEDIATION / REMOVAL

Beaver BestWall Patents help give product ingredients

On your Beaver BestWall board we found the patent numbers below, giving more information about this product BestWall product.

It's often informative to review the patents for mention of use of asbestos in the Beaver board.

Indeed some of these BESTWALL DRYWALL PATENTS & LABELS do cite the use of asbestos, as we'll see below, though the patent information itself is not necessary the whole story of your particular board product.

Click that link above to see the Beaver BestWall patents we've researched, and note that most of these patents are assigned to US Gypsum Co., some of whose products contained asbestos.

...





ADVERTISEMENT





...

 

Continue reading  at BESTWALL DRYWALL ASBESTOS - topic home, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

BESTWALL DRYWALL ASBESTOS FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to ASBESTOS HAZARDS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.


Comment Form is loading comments...

 

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.

In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.