Propane, LP, or Natural Gas cooking appliance repair procedures & manuals.
This article series explains the cause, diagnosis, and cure of gas appliances, including gas cooktop or gas range igniter problems that cause continuous clicking, or failure to ignite gas burners or a gas oven properly.ed.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
Gas Cooktop Range & Oven Installation & Repair Guides
Here we give basic diagnostic and repair steps for gas fueled cooking appliances and we provide provide installation, service, and users guides for popular cooktops and ranges that use propane, LP gas or natural gas.
Shown here: the Bertazzoni-MAS304GASXE Freestanding 30-inch Gas Range
[Click to enlarge any image]
Gas Range & Gas Oven Troubleshooting & Repair
Photo: antique Rainbow gas stove photo contributed by an InspectApedia.com reader. [Click to enlarge any image]
Watch out: Gas ranges burn either natural gas or propane. Switching fuels is possible, but some equipment modifications are necessary.
If a gas burner will not light, this may be caused by no gas supply to the range, no electrical supply
to the range, the pilot being out, blocked gas ports, faulty gas valve, faulty igniter or defective controls.
Yellow flame or gas odors or both: A yellow flame (rather than blue) indicates a poor fuel/air mix, requiring an adjustment.
Gas oven troubles: gas ovens can have problems
Problems with burners that are out of adjustment or clogged. Burners can also suffer corrosion.
Pilot, spark and electronic ignition systems may be inoperative or may operate inconsistently.
[Click to enlarge any image]
Oven Hazards
Watch out: Defective oven doors can open violently, or fail to close properly, and obstructed oven vents can cause the oven to overheat.
Oven door gasket problems may prevent doors from closing tightly, causing inefficient operation and overheating of the kitchen.
Where an anti-tip bracket has not been provided, the oven can tip over and cause injury.
This can happen if children stand on an open oven door to reach for something, for example.
Our close-up photo of a modern oven door gasket shown here was provided by a reader who was worried that the gasket was releasing harmful fiberglass into her home.
This was not a valid concern: the gasket, which is not made of fiberglass, sheds so few fibres that it would not be a detectable source of airborne fibres in the home unless it were somehow severely mechanically damaged.
Watch out: the glass on glass-fronted oven doors can shatter suddenly, risking injury to anyone nearby - at least on some models such as older Jenn-Air wall or built-in ovens.
Bosch, 1901 Main St., Suite 600, Irvine CA 92614, Customer Service Tel: 800-944-2904, Bosch Parts: 877-403-3185, Website: www.bosch-home.com or Website-Canada: https://www.bosch-home.ca
BOSCH NGM GAS COOKTOPS INSTALLATION MANUAL [PDF] (2015) Models: NGM Gas Cooktops NGM5055UC, NGMP5055UC, NGM5655UC, NGM8055UC, NGM8065UC, NGM8655UC, NGM8665UC, NGMP655UC
BOSCH NGM 5056-P656 GAS COOKTOPS INSTALALTION MANUAL [PDF] (2017) Models NGM5056UC, NGM5656UC, NGM8056UC, NGM8656UC, NGMP056UC, NGMP656UC, Bosch BSH Home Appliances, 901 Main Street, Suite 600, Irvine, CA 92614 USA, Tel: 800-944-2904 Web: www.bosch-home.com
Bosch, "Gas Cooktops Installation Manual, NGM Gas Cooktops (NGM30, NGM50, NGM 56, NGM80, NGM86, NGMP65)", (2013), Bosch, 1901 Main St., Suite 600, Irvine CA 92614, Tel: 800-944-2904, Website: www.bosch-home.com
Bosch, "LP Gas Conversion Kit Installation Manual , NGM Gas Cooktops (NGM30, NGM50, NGM 56, NGM80, NGM86, NGMP65)", (2014), Bosch, 1901 Main St., Suite 600, Irvine CA 92614, Tel: 800-944-2904, Website: www.bosch-home.com
Bosch, "Gas Cooktops Use and Care Manual, NGM5055, NGM8055, NGM8065, NGMPO55, NGM5655, NGM8655, NGM8665, NGMP655", (11/13), Bosch, 1901 Main St., Suite 600, Irvine CA 92614, Tel: 800-944-2904, Website: www.bosch-home.com
CARLIN EZGAS PRO™ Gas Burner INSTRUCTION MANUAL [PDF] Carlin Combustion Technology, Inc., 126 Bailey Road, North Haven, CT 06473 USA Phone: (203) 680-9401 Email: info@carlincombustion.com, retrieved 2017/12/31
FRIGIDAIRE GAS RANGE USE & CARE GUIDE [PDF] (April 2002), Contact: Electrolux USA, Electrolux Major Appliances North America, PO Box 212378, Agusta GA 30907 www.frigidaire.com USA: 1-800-0944-9044 or Canada: Electrolux Canada Corp. 5855 Terry Fox Way, Mississauga Ontario Canada L5V 3E4 Tel: 1-800-265-8352 No. 316901202
Watch out: Most manufacturers require that installation and fuel conversions shall be performed by a trained and qualified service technician. The technician should be sure to correctly identify the model number of your gas appliance so that s/he can follow the correct details of the manufacturer's instructions.
GE GAS COOKTOP MANUAL Model ZGU384NSM2SS [PDF] (2006) covers both LP gas model ZGU384L and Natural Gas model ZGU384N. GE Consumer & Industrial,
General Electric Company
Louisville, KY 40225 USA Website: ge.com Tel: 1-800-GE-CARES Website: www.monogram.com
GE-Canada: Website: www.GEAppliances.ca
Appelez le Centre de r_ponse 1.800.361.3400 ou visitez notre site www.electromenagersge.ca
Glenwood Range Company, Customer Service, 435 Park Ave., Delaware OH 43105, 614-363-1381, Glenwood-Sunray Service Center: 215-682-4211.
Harper Wyman GENERATION SIX OVEN THERMOSTAT [PDF] Harper-Wyman Company, Subsidiary of Oak Industries, Inc., 3600 Thayer Court, Suite 110, Aurora IL 60504 USA, Tel: 708-978-8000
Jenn-Air advises that if your servicer cannot fix the trouble with your gas cooktop, you can contact
Maytag Appliances Sales Company, ATTN: CAIR® Center, PO Box 2370, Cleveland TN 37320-2370 Tel: 1-800-688-1100 or TTY: 1-800-688-2020. Be prepared to provide your name, address, telephone number, product model number, serial number, name and address of your dealer/servicer, a description of the problem, and proof of purchase (sales receipt).
Note: Jenn-Air was purchased by Maytag in 1982; Maytag was purchased by Whirlpool Corp. in 2006.
Kucht Pro, GAS RANGETOP INSTALLATION & USERS MANUAL [PDF] Models KRT3618U, KRT3003U, Kucht, 700 Route 46 West, Unit #3
Clifton, New Jersey 07013 USA Tel: 866-685-8248 Web: www.kucht.com as listed by Sears, retrieved 2021/12/23 original source: https://i.sears.com/s/d/pdf/mp-tc/10378807/prod_12004351804
MANUALS & PARTS GUIDES - HVAC - home - Master Index to All Brand Names & A-E HVAC manuals, wiring diagrams, installation and repair guides\
LG GAS COOKTOP INSTALLATION MANUAL [PDF] with installation instructions for both LG 30-inch and LG 36-inch gas cooktops. Retrieved 2020/03/31original source LG, Product Support, https://www.lg.com/us/support/product/lg-LCG3011BD.BBDELGA
Magic Chef Antique gas range at Dubois Farms, in Highland NY.
MABE GAS RANGE & COOKTOP MANUAL [PDF] in Spanish and English, Mabe models EM4004-EM805C, CEM7601-7683C, CMA07666-0785C, MA)1758-0805 Freestanding Gas Ranges Estufas de Piso, MABE, Website: http://www.mabe.com.mx/coccion or http://www.mabeinternational.com/ Email: mabeinternacional@mabe.com.mx
MABE is a Mexican-owned appliance company distributing appliances world-wide and marketed under a variety of other brands including Most General Electric gas ranges and refrigerators.
Rheem Corporation, "Conversion Instructions, Natural Gas to LP Gas", FaxBack 1506 These fuel conversion instructions are limited to Manufactured Housing products only. Retrived 4/28/14, original source: http://www.rheem.com/docs /FetchDocument.aspx?ID=1c3868ba-1cdc-4e3f-8aec-b7c7a4a1d137
Sears: see Kenmore appliances above on this page.
SMEG PGA96 GAS COOKTOP INSTALLATION & REPAIR MANUAL [PDF] Smeg Australia Pty Ltd, ABN 33 146 901 082, Head Office 2 - 8 Baker St, Banksmeadow, NSW 2019 Australia, Fax +61 2 8667 4800 Email: info@smeg.com.au retrieved 2020/05/25 original source: https://www.smeg.com.au/smeg_au/docs/user_manuals/PGA96.pdf
Illustration: an excerpt from Viking's LP-NG cooktop conversion kit instructions.
VIKING GAS COOKTOP & RANGE MANUAL [PDF] Viking Range Corporation,111 Front Street, Greenwood, Mississippi 38930 USA Tel: (662) 455-1200 1-888-VIKING1 (845-4641)
Website: vikingrange.com, retrieved 2018/08/18, original source: http://www.vikingrange.com/MEDIA_CustomProductCatalog/m2730059_F20542.pdf
VIKING GAS COOKTOP FUEL CONVERSION KIT LP-NATURAL GAS [PDF] LPKPDR - Universal LP Conversion Kit for
Professional & Designer Ranges/Rangetops, retrieved 2018/08/18, original source: http://www.vikingrange.com/MEDIA_CustomProductCatalog/m6450639_F20525_EN.pdf
Other Viking range documentation and manuals can be found at https://www.vikingrange.com/consumer/category/products/specifications-and-documentation
WHIRLPOOL Gas Range USERS MANUAL [PDF] - W10392928A for several models, retrieved 2017/10/18. Whirlpool COrporation, Website: www.whirlpool.com Tel: 1-800-253-1301
Contact Whirlpool for service: https://www.whirlpool.com/owners.html Telephone: US: 1-866-698-2538 Canada: 1-866-698-2538
Other Whirlpool appliance manuals: https://www.whirlpool.com/services/manuals.html
See additional citations
at our page bottom References or Citations
...
Continue reading at GAS IGNITER DIAGNOSIS & REPAIR where we discuss diagnosing and fixing gas ignition problems at LP or natural gas heaters, furnaces, water heaters and other appliances, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.