Aerobic Treatment Unit Septic Tank aeration pump brands, suppliers, sources, parts, instruction manuals.
This article series provides the size and design requirements for aerobic septic tanks or ATUs and aeration pumps. no fee. The page top illustration of a four-chamber aerobic wastewater treatment unit is adapted from the New Zealand Taranaki Regional Council's sewerage system guide.[5]
Page top image: a Secoh EL 80-17 diaphragm pump used on aerobic septic systems and discussed in this article.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Aerobic Septic Systems & Aerator Pumps & Pump IO Manuals
Here is a list of aerobic septic pump manufacturers or suppliers. Companies are welcome to contact us to add to this list.
InspectApedia.com has no financial, business, nor any other connection with companies or products discussed at this website.
AQUA SAFE INSTALLATION MANUAL [PDF] (2007) Class I Wastewater Treatment Plants Installation, Operation, Maintenance and Trouble-Shooting Manual for Distributors, Installers, and Maintenance Providers Ecological Tanks, Inc. 2247 Hwy 151 North Downsville, LA 71234 PH (318) 644-0397 * FAX (318) 644-7257 Aqua Safe Models AS500 AS600 AS750 AS1000 AS1500 AS500EZ AS600EZ AS750EZ AS1000EZ AS1500EZ AS500-CU AS600-CU AS500-3DUO AS600-3DUO AS500+5DU0
provided by the Stark County OH government, retrieved 2019/02/18, original source: https://www.starkcountyohio.gov/StarkCounty/media/StarkCounty/StarkCountMain/Public%20Health/Documents/AquaSafeInstallationManual2007-1.pdf
Gast septic aerator pumps, Gast Manufacturing, Inc.
2300 M-139 Highway
Benton Harbor, MI 49023-0097
Office Phone: (269) 926-6171, E-mail: technical.gast@idexcorp.com - USA or
Gast is owned by IDEX corporation.
HIBLOW aerobic pumps for residential aerobic septic systems, support documents (in addition to HIBLOW manuals listed below) http://www.hiblow-usa.com/wp-content/uploads/2017/01/DUO_Manual.pdf
or
HIBLOW USA, 1300 Tefft Ct. Suite 8, Saline, MI 48176 USA, Tel: 734-944-5032
For residential aerobic septic systems HIBLOW provides the DUO series, Duo 60 and Duo 80, the HP-Alarm series of septic system aeration pumps, HP 40-A - HP 200A, and the HP-Series aerobic Pumps HP-20 - HP 200, also the XP Alarm Series XP-40A - XP-80A and XP Series XP-40 through XP80 aeroibic septic aerators. The company also provides a manifold that permist coupling up to 5 HP- aerobic pumps in parallel for aerobic septic systems requiring higher airflow rates.
For still higher airflow rates for aerobic septic designs see the company's commercial septic aerator pump line.
Watch out: according to HIBLOW a Chinese company is manufacturing "knock-off" copies of HiBlow aerator and other pumps. The quality, performance, reliability, and warranty of knock-off copies of equipment may not be acceptable.
Septic Solutions, Inc., 314 W. Center St., Dieterich IL 62424 USA, TEl: 1-877-925-5132 Website: http://www.septicsolutions.net/ Email: sales@septicsolutions.com
Distributes Alita Air pumps, Cyclone air pumps, HiBlow and HiBlow Dual port air pumps, Medio Piston type air pumps, Regenerative Blowers, Secoh Air Pumps, Thomas Air Pumps,
Spunair septic tank aerators, 4501 Anderson Rd, Cleveland, OH, 44121 USA, Tel: (216) 538-4070 or possibly: (800) 760-7786, Website: http://www.spunair.com/ - website dead 2022/09/26 - Ed.
Wastewater.com, 111 Vernon Rd
Aledo, TX 76008, Website: http://tgwastewater.com/
TOILETS, WATERLESS ALTERNATIVES Composting Toilets, Biological Toilets, No-water/Low water toilets, Waterless toilets, Chemical Toilets, Incinerating Toilets and related products list
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Questions & answers or comments about septic effluent disinfection systems - chemicals to use and others to avoid using
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
[5] "Looking after your household sewerage system," New Plymouth District Council, Taranaki NZ, newplymouthnz.com, retrieved 4/4/13, [copy on file as Septic_Maintenance_Taranaki_NZ.pdf]
"International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
"Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental
Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
US HEW, MANUAL of SEPTIC TANK PRACTICE [PDF] 1975, U.S. Department of Health, Education and Welfare, Public Health Servicve, original source: https://nepis.epa.gov/
Manual of Septic Tank Practice, US Public Health Service's 1957, reprinted in 1963, 1967, 1969 and in a 1975 edition given just above.
Pennsylvania State Fact Sheets relating to domestic wastewater treatment systems include:
Pennsylvania State Wastewater Treatment Fact Sheet SW-161, Septic System Failure: Diagnosis and Treatment
Pennsylvania State Wastewater Treatment Fact Sheet SW-162, The Soil Media and the Percolation Test
Pennsylvania State Wastewater Treatment Fact Sheet SW-l64, Mound Systems for Wastewater Treatment
Pennsylvania State Wastewater Treatment Fact Sheet SW-165, Septic Tank-Soil Absorption Systems
Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006). Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text I recommend for professionals--DF.
US EPA Onsite Wastewater Treatment Systems Manual [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems,
Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers.
U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
"International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
"Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental
Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
Onsite Wastewater Disposal, R. J. Perkins;
Quoting from Amazon: This practical book, co-published with the National Environmental Health Association, describes the step-by-step procedures needed to avoid common pitfalls in septic system technology.
Valuable in matching the septic system to the site-specific conditions, this useful book will help you install a reliable system in both suitable and difficult environments. Septic tank installers, planners, state and local regulators, civil and sanitary engineers, consulting engineers, architects, homeowners, academics, and land developers will find this publication valuable.
Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around, suffering a bit from small fonts and a weak index. (DF volunteers to serve as indexer if Burks/Minnis re-publish this very useful volume.)While it contains some material more technical than needed by homeowners, Burks/Minnis book on onsite wastewater treatment systems a very useful reference
for both property owners and septic system designers. We refer to it often.
While Minnis says the best place to buty this book is at Amazon
Septic Tank/Soil-Absorption Systems: How to Operate & Maintain, Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf
US EPA ONSITE WASTEWATER TREATMENT SYSTEMS MANUAL Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.