Water Pump Pressure Switch Q&A
More water or well pump pressure control switch FAQs:
Second set of questions and answers on how to adjust the pressure control switch for a water or well pump.
This article series answers commonly-asked questions about how to adjust a well pump or water pump pressure control switch. We provide pump pressure setting advice, procedures & questions & answers about adjusting the pump switch.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
These questions were posted originally
at WATER PRESSURE CONTROL SWITCH ADJUSTMENTS - be sure to see that article if you need to adjust the settings on your pressure control switch for your water pump or well pump.
Also see our index to all water pump control switch FAQs at WATER PUMP PRESSURE SWITCH REPAIR FAQs
The individual well pump control switch repair article links below explain exactly how to set the water pump pressure switch, where the adjustments are located (the large and small nut found under the switch cover), which way to turn the nuts to increase or decrease the pump cut-in and cut-out pressures, and other pressure switch troubleshooting and repair procedures
...
I have a SquareD 2-adjustment pressure switch, very old approx 42 years in service. Type FSG9C. The pump is not turning off until 70 psi.
The range is 32-70 between on and off.
The upper cutoff adjustment (small spring/screw) was adjusted to be completely loose so that there is no spring pressure applied yet the upper cut off limit did not lower from 70 psi.
Adjusting only the large screw CCW moved the range from 38-75 down to 32-70.
I want the upper limit lowered to about 60psi but this cannot be done. Is the pressure switch at fault?On 2018-06-20 3 by allan
Suggestions by (mod) -
Possibly but I suspect the switch is not properly adjusted.
See our detailed procedure at RESSURE CONTROL NUT ADJUSTMENT SEQUENCEWatch out: setting the pressure control or any other condition that sends water system pressures above 70 psi risks water leaks and sending water pressure above the water tank's rated pressure range (usually 100 to 150 psi) risks a burst water tank that can flood the buidling and can injure bystanders.
...
My well is not quite a year old, we have always had plenty of water and pressure. we have been watering trees in yard, now for some reson our pup runs out of water. It recovers with in 5 to 10 min .
The guage kicks on at 40 ps and should kick off at 60 or so. It kicks on fine but kicks out at 50 , is it the pressure switch? If I hold the switch down manually it pups and kicks out at 60 or 65 - Shaun Aden 8/4/11
Reply:
Shaun the pump might still be actually going off at 60 if the gauge is clogged with debris and reading inaccurately. Else if no one "adjusted" the switch and it's cutting off early it's time to replace it.
My pressure seems to cut out entirely, usually right in the middle of a shower, then takes 1 to 2 mins to cut back in. I tried making the cut-in pressure higher, but it did nothing.
My pressure also seems to go too high, around 70 psi. But nothing I do seems to help. Do I just need a new switch? - Jeran 5/20/12
Reply:
Jeran I'd start by checking for a pump switch that has a clogged sensor port or pipe - clogging can slow the pump switch's response to an actual pressure drop in the system
...
how to switch off a motor pump if the cistern tank has no more water ? - Roselle 8/11/11
Reply:
Roselle every pump circuit should have a manual service switch installed for manual cutoff.
If there is no electrical switch to turn off the pump, ask your electrician to install one at next electrical work. In that case,
if someone wired the pump directly with no local on-off switch that would be unusual but in that case you'd have to
If you are asking how to prevent the pump from running when there is no water available, ask your well or plumbing supplier about a tailpiece that prevents the pump from running or running dry when the water level falls too low in the well or cistern.
...
Genesis pressure control switch pressure adjustment
moved to GENESIS Pressure Control Switch Adjustment
Water Pump Turns on Immediately When we Run Water and How do I add air to the pressure tank?
are now discussed at
...
...
Continue reading at a href="../water/Pressure_Switch_Nut_Adjust.php">WATER PRESSURE CONTROL SWITCH ADJUSTMENTS - topic home, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
WATER PUMP PRESSURE CONTROL ADJUST FAQs7 at Ins pectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.