Rheem electric water heater Christ Church New Zealand (C) Daniel Friedman at InspectApedia.com Rheem Water Heater Age, Manuals, Customer Service Contacts

Rheem Water Heater, Geyser, Cylinder, Calorifier Contacts & Water Heater Manuals

Determine the age of a Rheem water heater based on decoding the serial number.

We give contact information for Rheem brand water heaters, geysers, cylinders, calorifiers and for Rheem water heater installation, operation, & troubleshooting manuals.

The water heater age guide on this page works for these brands: AquaTherm, General Electric, GE, Hotpoint, Professional, Rheem, Vanguard, & Western Auto water heaters.

Page top photo: a Rheem brand electric water heater installed in a Christchurch New Zealand home.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

Rheem water heater age determination, serial number decoding, manuals

Rheem RTREX-13 Tankless Water Heater (C) InspectApedia.com customer service not provided by Rheem nor by EemaxRheem Water Heater Contact Service, Repair, Warranty & Parts Contacts

Photo above: Rheem RETEX-13 electric tankless water heater purchased from Home Depot and installed by the author.

Leaks at a fitting led to a surprising discovery about this heater described separately

at RHEEM TANKLESS WATER HEATER LEAK REPAIR

[Click to enlarge any image]

On Rheem tankless water heaters like the one shown below, the unit serial number is found beneath a QR code on a sticker on the right side of the exterior of the unit.

 

Modern Rheem Serial Number Decoder to Determine Heater Age

Rheem tank-type water heaters use a 10 digit code:

Rheem water heater label data (C) Daniel Friedman Boca Raton FLMMYYX12345 where X is the plant code and 12345 a consecutive unique ID and of course MM YY are month and year.

Photo: Rheemglas Fury model Rheem water heater data tag on a home in Boca Raton Florida. Serial No. RH 0806B17262 decodes to August 2006.

Really? Sometimes it's easier to read the manufacture-date right off of the Rheem water heater data tag where you may see a field titled: MFG. DATE: MM/YYYY

On the Rheemglas Fury water heater data tag shown here we see MFG. DATE: 08/2006

We discuss Rheem-manufactured water heater date codes in more detail below.

The Rheem water heater serial number is found on the data tag or label on your water heater's exterior.

[Click to enlarge any image]

A different example is shown in our photo at the top of this page: Some Rheem water heaters such as this electric water heater made by Rheem New Zealand and installed in a Christchurch home will give the date of manufacture explicitly.

This New Zealand Rheem water heater was manufactured 14/05/2007 and sports a serial number of 0723.

On Rheem tankless water heaters
the serial number is located inside of the heater body on the right side.

On Rheem heat pump water heaters
the serial number is located on a label on the upper left side of the unit.

Rheem produced water heaters sold under many other brands including

Rheem-made Hotpoint Water Heater Data Tag gives water heater age (C) InspectApeida.com Randy Coulter

[Click to enlarge any image]

Rheem serial numbers on modern heating equipment can be decoded by mapping the corresponding digits of the unit's serial number as follows:

MMYYPnnnn

where

MM = month of manufacture

YY = year of manufacture

P = plant identifying code

nnnn = a consecutive serial number for your individual unit

Rheem water heaters that may be sold under other brand names include

AquaTherm water heaters, General Electric water heaters, Hotpoint water heaters, Professional Brand water heaters, Vanguard water heaters & Western Auto water heaters.

- http://globalimageserver.com/FetchDocument.aspx?ID=682d9e43-35ec-48e9-b3f7-1a41d328375d retrieved 6/24/2014

Contact information & Manuals for Rheem Water Heaters

Rheem New Zealand water heater data label information (C) Daniel Friedman at InspectApedia.com

Rheem Water Heater Manuals

Also see

 

Nine Rheem Water Heater Serial Number Decoding formats

Rheem water heater label data (C) Daniel Friedman Boca Raton FLThank you for the added information, Nick.

I will continue researching to see if we can find a key to older Rheem water heaters that pre-date the modern date encoding schema.

Because Rheem water heaters or calorifiers or geysers were sold under quite a few brands and over many years, there is a plethora of Rheem water heater serial number formats.

Rheem provides their own Rheem water heater age decoder at https://www.rheem.com/how-old-is-my-water-heater however we found that this web page does not work on older Rheem water heater serial numbers.

To date we have found at least nine Rheem water heater age encoding schemes depending on the era of manufacture and also on the type of water heater. We summarize these below.

Photo: an older Rheemglas Standard water heater, Serial No. # R 0884B10488 decodes to August 1988.

[Click to enlarge any image]

Rheem current 10-digit serial number code: MMYYP12345 where

P is the plant code and 12345 a consecutive unique ID and of course MM YY are month and year of production.

This serial number may be prefixed by R, RN, RNG, RHNG or other letter combinations.

Rheem 8-digit serial number: 1234WWYY ?

Uncertain, possibly WWYY are week number and two-digit year number for older Rheem water heaters like the Rheemglas glass lined water heater

Rheem 9 digit serial number code with alphabetic prefix: ABCDMMYY2345

MM and YY are the month and year of production.

ABCD in this serial number format may be 1 to 4 alphabetic characters in length: R, RN, RNG, RHNG, RHUNM or other letters. The MMYY are the first numeric characters in the code.

Example: RN 1292A29282 - 12 92 or December 1992

Alternative Rheem 9 digit serial number code using week number, with initial character: ZWWYY12345

WW is the consecutive week number (1-52) and YY is the two digit year code

 

Rheem water heaer with 10 digit all numeric serial number - age decoded (C) InspectApedia.com Hogue

Rheem 10 digit serial number code without plant code: MMYY123456

MM YY are month and year of production.

This serial number may be prefixed by R, RN, RNG, RHNG or other letter combinations.

Alternative Rheem 10-character serial number code without plant code: MM.YY-123456
MM.YY are month and year of production.

This serial number format is used on some Rheem tankless water heaters.

Shown above: a Rheem water heater sporting a ten-digit all-numeric serial number.

In this example the heater's serial numb er is 09815101633, telling us that it was made in September 1981.

 

Rheem 11-character serial number code with plant code: MMYYP123456

MM YY are month and year of manufacture, P is a plant code.

This serial number is used on certain Rheem tankless water heaters.

Rheem 12-character serial number code: B950-3138 RCY-5

This serial number was provided by reader Nick 2018-08-27 and has not been precisely de-coded.

Nick adds that the heater was made on or before 1978 and he speculates that the B950 could refer to B-Baltimore and 950 to 9 - September and 50 - 1950.

However Rheem does not have and appears not to have had a manufacturing facility in Baltimore, Maryland.

Rheem 16-character serial number code with plant code: ZMMYYP12345689X
MM YY are the month and year and P is a plant code.

...

Rheem Water Softener / Water Treatment Equipment Manuals

For Rheem water softeners

 

...




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

How to figure the age using this non-standard Rheem water heater serial number

Need to know age of my water tank, and expiry date. CN1207207623 On 2020-06-04 by sidhamstra@gmail.com

Reply by (mod) -

Sid

If that's a Rheem serial number, it doesn't exactly match the 9 Rheem water heater age decoder formats given above, but a reasonable guess is

CNYYMM or less likely CNMMYY so that's Dec 2007 - (my second example)

You can do a sanity-check on a water heater decoded age by sharing (with us) some basic data such as

The country and city where the water heater is installed

The age of the building

and for more detailed guidance please check out

DATA TAG DECODING ADVICE for NON-STANDARD DATE CODES - general procedure

I Can't find the age of this old Rheem water heater

Rheem water heater data tag & instructions (C) InspectApedia.com Lindy

Can’t find the age On 2020-06-02 by Linda

Compare the serial number with the article above. Your Serial No. for your Rheem water heater is S 760 2280 RDON 1YR

Rheem water heater data tag & instructions (C) InspectApedia.com Lindy

Frigidaire Water Heaters by General Motors, see Rheem

Frigidaire General Motors Electric Water Heater from 1961, Plant City FL (C) InspectApedia.com reader

Mod - approximately 1961 Plant City, FL

only other picture is of a cover plate.

Any serial number tag may be hidden on the backside of unit under cabinet. Thanks for the interest. On 2020-04-27 by Anonymous

by (mod) -

Nice photos of your antique Frigidaire water heater logo, stamps on the actual heater tank, and proof that the GM or Frigidaire water heater was actually manufactured by Rheem; thanks.

Sometimes we can find patent nos. that set a floor under the possible age.


What's the age of this galvanized tank Rheem water heater?

Rheem Water Heater Frigidaire Part No. 3429120 (C) InspectApedia.com CharlieI'm trying to find the age of this water heater. can’t see a plate/tag but info is painted on the side of the galvanized tank. see image. On 2020-04-26 by Charlie

by (mod) - Age of Frigidaire Part No. 3429120 water heater made by Rheem

Well that's a great photo, Charlie. If you can also post a photo of the whole heater that'd be great.

This is quite obviously a Frigidaire branded water heater with

Frigidaire Part No. 3429120, made by Rheem,

as Rheem produced heaters sold under many brands.

I've searched under both brands and part numbers without a hit.

Tell me if you can

The country and city where this heater is installed

The age of the building where it is or was found

Also see WATER HEATER AGE GUESSER

Age of a Rheem boiler mod PGW-120B? Nobody at Rheem knew

How old is this Rheem boiler mod PGW-120B. SN. A68CN3X contacted Rheem and ray pack no one knows On 2019-11-04 by Adam

by (mod) - Rheem WATER HEATER model PGW-120B

Thanks for the puzzle, Adam.

Indeed Rheem WATER HEATER model PGW-120B sporting serial number SN. A68CN3X doesn't quite fit the known serial number decoding patterns for Rheem.

There are other ways to make a reasonable guess at the age of an older water heater (that you referred to as a boiler)

How old is the building where the heater is installed ? - this is close to the oldest the water heater (calorifier, geyser, hot water cylinder are synonyms) might be, more or less

Is this the original water heater or a replacement ? making it newer than the building.

Are there any manuals around? Those will have publication dates and often as well a hand-written installation date.

Are there service or data tags or notes on or close to the boiler itself? Those can set a likely installation or first-service date.

Post a photo of your boiler and using a second comment post a photo of its data tag and I'll research further.

More help at figuring out the age of a water heater when the serial number or data tag is missing, incomplete, or confusing is at

WATER HEATER AGE GUESSER


How to find out the age of this old water heater tank - Photos of a 1980's Rheem water heater

Rheem water heater data tag 1960s (C) InspectApedia.com NickI would like to find the age of a model 81v40d eke water heater . The serial no. Is r 0791124875

by (mod) - Age of a Rheem Model #62-52-D; Serial #B950-3138 RCY-5.

Nick

Typically on a Rheem water heater the age is encoded in a 10-digit serial number as MMYYa12345

Your heater's serial No. is B95-3138 RCY-5 which of course doesn't fit the schema of newer Rheem units.

by Nick

Thanks again. The only reason I speculated about Baltimore is because it was listed on the nameplate along with 5 other cities (Los Angeles, New York, Baltimore, San Francisco, Chicago, & Houston).

Nick,

Thanks, these are great photos. I

I'll be sure to copy them over to our new page dedicated to Rheem water heaters and found above on this page.

We'll continue researching this heater and will see if anyone at Rheem can help.

by Nick Rheem stopped using the logo below before 1980

I researched Rheem's history and it looks the they stopped using the logo pictured on the front of the unit sometime prior to 1960.

Thanks for your reply.

Here is the nameplate.

I'll get some pictures of the unit itself tonight.

Rheem logo on a 1960s Rheem water heater (C) InspectApedia.com Nick

Nick

Thank you for the added information.

I will continue researching to see if we can find a key to older Rheem water heaters that pre-date the modern date encoding schema.

1960s Rheem water heater (C) InspectApedia.com Nick

by Nick

I saw it, but the formats didn't match.

1960s Rheem water heater (C) InspectApedia.com Nick

The # on the unit is B950. Baltimore - September 1950, possibly. I know the unit is at least 40 years old.

by (mod) - Thermostat on a 1980's Rheem electric water heater

1960s Rheem water heater (C) InspectApedia.com Nick

Above: the control thermostat on Nick's 1960's Rheem electric water heater.

Did you see Rheem water heater age decoding at

RHEEM WATER HEATER AGE & MANUALS

 

What's the Age of a Rheem model #61v520 serial #R0388105478

Looking for the Age of a Rheem model #61v520 serial #R0388105478 On 2014-09-13 by Anonymous

Reply by mod:

#R0388105478 - March of 1988

What is the life expectancy of a Rheem hot water cylinder

How many years should a Rheem hot water cylinder last ? (Oct 26, 2012) meme

Reply:

Meme, Rheem's warranty period for hot water heating equipment (cylinders, geysers) varies by product series but is typically 5-10 years.

But I've found water heaters still working perfectly even at 30 or 40 years old - usually gas fueled models and occasionally oil fired water heaters.

You will need your product name and model number as well as serial number to look up the exact information for your unit.

For example, the HPWH has a 10-year tank leak warranty and a 10-year parts warranty and a first year in-home labor warranty is included as well.

Some Rheem heating equipment such as gas furnaces includes longer periods for the heat exchanger, such as 20 years or "lifetime".

You should be sure to register your hot water cylinder at the company's website as that will aid in any future warranty claim.

You can call Rheem directly for help. In North America call 1-800-621-5622 and listen for the prompt to take you to warranty information provided by the company

...

Continue reading  at RUUD & RHEEM HVAC AGE & MANUALS - A/C, Heat Pumps, Furnaces or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

RHEEM WATER HEATER AGE & MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER HEATERS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Questions & answers or comments about how to find out the age of a heating appliance: water heater, heating boiler, heating furnace.

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.


Comment Form is loading comments...

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.

In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.

  • Scott C. LeMarr has provided his file of keys to decode Water Heater Age from the data provided on the manufacturer's equipment labels. Mr. LeMarr is a professional home inspector, Certified Professional Inspector/President, MASTER Indoor Environmental Specialist (MIES). Vice President of Wisconsin NACHI. He and his company, Honest Home Inspections [ Website: www.HonestHomeInspections.com ], LLC. can be reached at 262-424-5587 or by email to scott@honesthomeinspections.com
  • Carson Dunlop, Associates, Toronto, have provided us with (and we recommend) Carson Dunlop Weldon & Associates'< Technical Reference Guide to manufacturer's model and serial number information for heating and cooling equipment ($69.00 U.S.). Technical Reference Guide, Carson Dunlop Weldon & Associates, Ltd., 120 Carlton St. Suite 407, Toronto, Ontario, M5A 4K2 Canada, ISBN 1-895585-90-2 165pp.
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Mr. Cramer serves on the ASHI Home Inspection Standards. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com
  • John Cranor [Website: /www.house-whisperer.com ] is an ASHI member and a home inspector (The House Whisperer) is located in Glen Allen, VA 23060. He is also a contributor to InspectApedia.com in several technical areas such as plumbing and appliances (dryer vents). Contact Mr. Cranor at 804-873-8534 or by Email: johncranor@verizon.net
  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested

    CONTINUE READING or RECOMMENDED ARTICLES.


ADVERTISEMENT