GE water heater age determination from serial number & sources of GE water heater manuals.
We give contact information for GE water heater, geyser, cylinder, calorifier manufacturers and for water heater installation, operation, & troubleshooting manuals.
We also include, by patent citations and illustrations, examples and history early electric water heater designs whose patents were held by the General Electric Company.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
Shown here, the data tag for a G.E. brand (General Electric) water heater.
[Click to enlarge any image]
A close-up photo of this GE water heater data tag is given below.
Serial No. GE A511315388
We format this GE water heater serial number as GE AWWYYnnnnn where 51 is the week (December) and YY is 13 or 2013.
The enlarged view of this data tag given below confirms this guess as it tells us explicitly that the Manufacture Date for this water heater was 18 Dec2013.
GE MMYY1234567 where MM indicates month and YY year of manufacture encoded numerically
GE AWWYYnnnnn
GENG MMYYP12345 where the NG refers to Natural Gas
GERNMMYY123456
GE Furnace Age Query: (Nov 18, 2012) Lyn said: I am trying to determine the age of my electric f.a. furnace.
It is a General Electric made in Toronto, Ontario.
The Serial number is Ser# 398 870 T21
The model number is BWL730G172B.
If someone could please advise the age of my furnace, it would be greatly appreciated.
Thanking you in advance.
Lyn
Reply: You've sent us a warm air heating system code not a water heater code. This article and comment page are for water heaters. For details on age determination for heating boilers & furances see AGE of HEATERS, BOILERS, FURNACES.
But I make your code as March 1998
For a complete guide to GE or General Electric HVAC and other equipment you will need to see the pages of data on GE found in Carson Dunlop Associates Associates comprehensive Technical Reference Guide.
Generally for GE water heaters the first one or two digits are the month and the next two the year of manufacture.
So your heater was made in month 3 and in year 98 - March 1998.
A glimpse of the long history of General Electric water heaters can be had by noting the dates and assignees of some of the earliest heater patents, including space heaters, in the U.S. like that of Thomson, below.
Above, George Stevens' electric water heater assigned to GE in 1909. Stevens also had earlier patents dating at least from 1906.
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
@Laurel,
History of GE Calrod water heaters
Doing some research on the Calrod
"Calrod is a trademark of the General Electric Company, but the term has become the
generic term used for tubular heating … The calrod design was apparently never patented." Hertzmann, Peter. "The Wire That Made Cooking Electric." (2020).
"The first sheathed-wire (later, "Calrod") heating units for electric ranges had been produced.
… throughout the laboratory's history. "
The earliest citation we've found for Calrod heaters dates from 1913
In 1913 General Electric patented a method of suspending a heating wire in … Calrod
manufacturing technology was no longer cost competitive with other types of small appliance heating … - George, William F. Antique Electric Waffle Irons 1900-1960: A History of the Appliance Industry in 20th Century America. Trafford Publishing, 2003.
Actually GE patents for electric heaters date from around 1908 - as you'll see in our GE water heater history and patent notes above on this page.
I also liked this patent that may well presage the Calrod Heater name later applied by GE (and still later that became rather generic)
Other early GE water heater patents are shown above on this page.
Earlier electric heating devices were patented well before 1900.
According to the company, the Calrod was invented by GE in 1915 - www.geappliances.com/ge/cooking-milestones/
The first Calrod electric ranges were introduced later, in 1928; the heater found use in irons, toasters and other appliances, not just in water heaters.
So what was the original "Calrod" made by GE?
A spiral-wound tungsten wire is coiled and inserted into a glass tube. The is then filled with purified powdered magnesite - to act as an insulator. The filled tubes are then heated (swaged) to solidify the construction and then may be bent or formed into a coiled heating element for a stovetop burner, an electric water heating element, an electric iron, etc.
Calrod" is a GE trademarked name for the main type of heater used in all sorts of devices. They use nickel chromium wire (Nichrome) encased in a steel tube. Vitrified magnesite is packed in the steel tube to provide electrical insulation, yet at the same time this material conducts heat very well. This is why if you touch a calrod heating element you don't get an electrical shock (in addition to the burns!).
Calrod technology is used in irons, ovens, stovetops, toaster ovens, dishwashers, electric heaters and other industrial ovens. - "Electric Stoves, Calrods and Cooking with Electricity" Edison Tech Center, edisontechcenter.org/Cooking.html
Recommended: see this movie (1928) on the history & manufacture of the Calrod by Hotpoint - General Electric -
archive.org/details/con_000012
On 2022-03-28 by Inspectapedia Com Moderator (mod)
@Laurel,
Thank you for the great photo of what looks like a rather antique GE Hotpoint water heater.
A close look at the data tag shows that the first four digits of the serial number 2725 are stamped cleanly, to the same depth, and in a straight line, while the remaining digits 955 are stamped into the plate at varying angles, spacing, and depth - suggesting that the manufacture date would have been encoded in the first digits and the squence number in the last (955).
That ducking and weaving about the question done, I don't know the manfacturing date for sure. A "standard" decoding would have put the manufacture date of the water heater as week # 27 in year 25 as in 1925. I'd be impressed if this heater is really that old.
The second most-common date arrangement for older GE water heaters put the year first, making it week 25 in year 1927 - equally remarkable but perhaps a better guess.
Can you find any service tags or an installation or instruction manual (often stored nearby) with any more information?
On 2022-03-28 by Laurel
How old is my water heater? The numbers for the serial number don’t make sense in determining the date: 2725955. My house was built in 1935. Thank you.
[Photo of Calrod water heater shown above]
On 2021-12-28 by (mod) Data tag on a Rheem - GE Electric water heater
Serial No. 0111533776
Your water heater's data tag nots that it was manufactured under trademark license (presumably GE?) by Rheem.
Take a look also
at RHEEM WATER HEATER AGE & MANUALS
That decoder gives
MMYYX12345 where X is the plant code and 12345 a consecutive unique ID and of course MM YY are month and year.
January 2011 is a guess per that decoder.
On 2021-12-28 by Calsey
@Calsey, I think it's 2001 November according to the serial number
What year is my HW tank. Thanks in advance.
On 2021-03-24 by danjoefriedman (mod)
@Kim,
Take a look at the GE serial number age decoding guide above on this page - you'll see that common encoding is WWYY for week number and year's last 2 digits, found in the first four numeric digits of the serial number; of course there can be other formats, as we describe in the article above.
Water heater age guess SANITY CHECK:
- start with a statement of the age of the building where the water heater is installed
- take a look at all of the information tags and stickers on the heater; the newest year or date on any of those will set a floor under the heater's possible age. For example if a water heater's Energy Rating sticker refers to a 2006 energy star code as its latest information, we know the heater could be as old as 2006 but no older.
- look for notes on the heater itself: often an installer will write the installation date on the heater
- look for notes on the heater's manual left with the heater, including the manual's publication year
- look at records for repairs, replacements to the buildings water heating system, plumbing, etc. - work receipts, check stubs, etc.
On 2021-03-24 by Kim
I am trying to determine the age of my GE Smart Water Heater Serial number GE 1106R13999. Can you please help me?
On 2021-03-10 by JEFF
Can you determine the age of the water heater by its Model or Serial #?
GE PROFILE PERFORMANCE
MODEL# -GE SE80T12A01
SERIAL# 0201C01386
On 2021-03-10 by danjoefriedman (mod)
Jeff
In the article above we give several GE water heater serial number formats that let us guess at its age
see "GE Water Heater serial number formats"
what I do is to step through those, compare each with your heater's serial number layout, and then perform a "sanity check" on what age that produces.
For example if we decode your GE heater serial no as made in 2002 January YYMM - as a common example, that would be credible if your home is that old or older.
On 2021-03-10 by jeff
How old is my water heater?
Model-GE SE80T12A01
SERIAL# 0201C01386
On 2020-10-12 by Doreen Langmead
QUESTION
My GE hot water tank - Serial Number GC 0609240545 is leaking. It was installed in 2009. This was because a replacement tank installed in 2004 also started leaking. Seems to me that GE hot water tank are not very good.
How old is my GE hot water tank?
Serial Number GC 0609240545
On 2020-08-17 - by (mod) -
I'm still looking for a GE water heater manual for a 66 gallon electric unit for you, John so far no luck.
If you're going to have to cut open the wall to remove or repair the unit, then perhaps it's time to bite that bullet and look at the heater element type directly.
From the serial number 769266 this is probably a GE water heater made in 1976.
On 2020-08-16 by John K.
Older GE tank water heater. Looking for both age and type of element mounting method. (screw-in or flange) Cannot reach elements without breaking a wall, would like to know if they are available before drastic measures.
Info from stamped metal plate on tank: GE, Calrod units. / 230 volts / Catalog no. G 662 A / Serial no. 769266 / Upper unit 2000 watts / Lower unit 1250 watts / 66 gal. cap. / 3250 watts total S.T, thermostat / 150 lb working pressure / 300 lbs. test pr.
Thanks heaps in advance!
My e-mail: DHCowdude@gmail.com
On 2020-08-07 by Isabelle
I am trying to determine the age of my GE Smartwater water heater. The codes give serial numbers starting GE but my serial number is GC 0406213940.
On 2020-06-07 - by (mod) -
Thanks for asking about the GE water heater age decoding procedure, Lynda
I make it as follows: looking at the serial number of your water heater
GELN MMYYP12345 where the LN refers to Liquid Propane or Natural Gas
and the next four numeric digits are MM YY or month and year - 06 99 June 1999
On 2020-06-07 by Lynda
Trying to determine the age of my GE water heater model GG50T6XA serial GELN 0699121611.
Thanks in advance,
Lynda
On 2020-03-20 - by (mod) -
Thank you for the question, Cynthia and forgive the delay in reply (we were traveling to a quarantine location)
We have two articles describing the location and adjustment of electric water heater temperature controls:
ELECTRIC WATER HEATER HIGH TEMP CUTOFF https://inspectapedia.com/plumbing/Electric_Water_Heater_High_Temp_Cutoff.php
ELECTRIC WATER HEATER THERMOSTATS https://inspectapedia.com/plumbing/Electric_Water_Heater_Repair.php#ElecTT
Basically, the electric water heater temperature control thermostat is behind a removable cover plate and can be adjusted up or down.
But
Watch out: removing the cover plate (as you'll see in the articles below) exposes LIVE electrical wire terminals - touch one of those and you could be shocked or killed. So don't do that.
Take a look at those articles and don't hesitate to ask follow-up questions.
On 2020-03-15 by Cynthia
How do I adjust the temperature
On 2019-12-27 - by (mod) -
Mark: a reasonable guess for your GE water heater is 65 = 1965 and 02 = May;
If that is plausible given your building's age then we'd add that for older 1960's water heaters the format can be YYMMnnn
On 2019-12-26 by Mark Collins
I have a GE water heater I'm having trouble determining the age for replacement purposes. Serial # 6502351.
On 2018-11-14 by Mike
GE water heater, serial # M291305611
Model # 30S06AAG
Thank you.
On 2015-03-09 by Anonymous
my GE gas water heater, serial # GENG 1100117425, and Modle # SG50T12A, would be approximately how old?
Rita
On 2015-02-06 by Kat
How old is my Hot Water Heater GE Mdl GG50T6A, S#GENG1200160571.
...
Continue reading at WATER HEATER LIFE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
GE GENERAL ELECTRIC WATER HEATER AGE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about how to find out the age of a heating appliance: water heater, heating boiler, heating furnace.
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.