Coleman Heaters Heating & A/C Equipment
This article provides Coleman Heaters HVAC company information, history, free PDF downloads of service manuals, and contact information for service and repair.
In addition to its famous Coleman lanterns and the Coleman gas stove that was a staple of heavy-camping trips for decades, the company produced electric and gas-fueled heating equipmen including an electric furnace and gas furnaces.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
History of Coleman Lanterns, Stoves, and HVACThe original Coleman company was founded Oklahoma in the U.S. by W.C. Coleman in 1900. Coleman's first product and its most famous was a line of lanterns that by 1914 were sold widely in the U.S. Coleman camp stoves were introdued in the 1940s, first as a portable or "pocket" stove used by soldies during WWII.
Coleman HVAC (Coleman heating and air condtioning equipment) originated in 1958, was purchased by MacAndrews & Forbes in 1989, then was sold on to Beacon International (Canada), also titled Beacon Capital Corporation, in 1990, when the company was renamed Evcon Industries.
Evcon was purchased by York International in 1994.
Active brand: Coleman Evcon.
Currently (1999-2022) ColemanĀ® Air Conditioning is a residential cooling system line produced and sold by York's Unitary Products Group which is, in turn, owned by Johnson Controls.
Photo: data tag for a Coleman Central Electric Furnace designed for use in manufactured and mobile housing and for installation on a combustible floor and in an alcove or closet.
More about this specific furnace is at ELECTRIC HEAT BASEBOARD DIAGNOSE REPAIR.
Coleman Furnace Error Codes |
|
| Flashing Light | Significance |
| Slow Green | Normaloperation |
| Slow Amber | Normal operation, call for heat |
| Rapid Flashing Amber | Low flame sense current Clean flame sensor Check adequate gas supply |
| Solid Red | Control failure |
| Rapid Flashing Red | Twinning error |
| Slow Single Red Flash | Gas leak Flame present, gas is off Check gas valve |
| Slow Double Red Flash | Pressure switch stuck closed Miswired pressure switch Faulty pressure switch |
| Slow Triple Red Flash | Pressure switch stuck open Check for faulty draft inducer Check for blocked vent Check for leaky pressure switch hose Replace pressure switch |
| Four Red Flashes | Limit switch stuck open |
| Five Red Flashes | Flame rollout switch stuck open Manually re-set roll out control Check draft inducer Check heat exchanger for damage |
| Six Red Flashes | Locked out pressure switch Furnace will lock itself off for 1-hour, then auto-reset |
| Seven Red Flashes | Ignition lockout Excessive re-tries Check for bad flame sensor Check for stuck gas valve Check / replace surface igniter Check burner for blocks, leaks |
| Eight Red Flashes | Ignition Lockout |
| Nine Red Flashes | Power ground or polarity error Check wiring polarity |
| Ten Red Flashes | Gas valve not closing when no call for heat Check gas valve Check gas valve wiring |
The flashing light error codes in this table apply to modern Coleman furnaces. Be sure to check the specific manual for your Coleman furnace model.
Typical Carrier serial number decoder:
WWYYA12345 where WW = Week and YY = year and A is an alphabetic character not part of the manufacturing date code.
or
YYMM12345 where YY = Year and MM = Month and note that there is no alphabetic character in the serial number
See details at the Intertherm and York links given above, and also for Coleman HVAC whose manual or label indicates Resco, see details at the decoding guide for Carrier HVAC serial numbers
at CARRIER AIR CONDITIONERS BOILERS FURNACES AGE MANUALS
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
I am seeking to identify compressor model I have in an old Coleman Evcon air conditioning unit. I need to identify a capacitor and capacitor is bad and compressor model number info is not shown. I have air conditioning unit model number and serial number. - Anonymous by private email 2022/07/31
Look for the data tag on your equipment, then see
CAPACITOR SIZE DETERMINATION for ELECTRIC MOTORS
Where you'll see general guidelines for motor start/ru capacitor selection when exact motor details are not known.
Also if you can, post photos here of your Coleman Evcon air conditioner and of any data tags you can find.
I have an Electric coleman 3400s furnace. In the beginning it will run fine and get the trailer to temp but shortly after the elements will light and the blower will stay off.
I put a new sinkurnizing relay on it and thought that fixed it.
Last night I woke to the smell of the elements cooking and no blower. What should I try next? AUTHOR:MikeHamilton (no email) On 2017-01-04
by (mod) your system is unsafe, should be left off, and you need help from a licensed electrician
Daniel:
Watch out: What you describe sounds very dangerous, risking fire or death from shock. It is possible that the main breaker you are turning off is a defective switch that
is not turning off internally even though you switch the toggle to OFF.Use the page top or bottom CONTACT link to send me photographs of the switch and of the furnace, being sure to include any visible labels or markings on the electrical box and switch.
Meanwhile, I suggest keeping people away from the furnace, keeping aware that ALL of the electrical components in the system might be unsafe, and that you should call a licensed electrician for help.
Coleman 7900 series mobile home furnace. I just bought this place as is condition.
Now my heating furnace won't start. It's a gas furnace. On 2018-09-28 by Cindy
by (mod) - when to call for gas fired heater repair
Cindy
Watch out: Because there are fire and life safety questions involved, if I were buying a new home that had gas-fired heat that wasn't working normally, I don't think I would feel with it myself I would call a trained service technician to be sure that the heating equipment and the chimney were working properly.Watch out: The risks of a fire or fatal carbon monoxide accident are just too serious to be casual about this.
Your service tech will check that there is a fuel supply and then check the ignition system and safety controls. When the burner ignites she will check to see that the combustion is proper and that the combustion air is proper in order to be sure that you're not facing a carbon monoxide Hazard.
Also be sure that you have working smoke and carbon monoxide detectors in your home.
...
Continue reading at FURNACES, HEATING - home, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
COLEMAN HEATER MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia