Log slab siding on a cabin Home Buyers/Owners Guide to Slab-Sided Log Homes

Log slab construction:

This article explains the construction, inspection & maintenance of a slab-log sided cabin. We explain how log-slab sided buildings are built, & how they work and including suggestions for durability, economy, and comfort in these modern log homes. We include illustrations of log structures from several very different areas and climates in both the United States and Norway.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

Guide to Log Slab Sided Homes or Log Siding - new construction

Log slab siding on a cabin

This series of articles provides information on the inspection and diagnosis of damage to new and older log homes and includes description of log home insulation values and alternatives, and also a description of the characteristics of slab-sided log homes.

Our page top photo shows a 2007 cabin restoration project. Slab log sided homes and cabins are buildings constructed using conventional wood frame or other methods, and whose exterior is covered with rounded wood siding cut or milled from logs.

However these homes or portions of homes built in this manner are not constructed using solid logs.

Our photo (left) shows areas of building walls re-constructed using conventional 2x6 framing with fiberglass batt insulation in the wall and ceiling cavities.

The log slab siding design also permits use of wood frame or panelized construction capable of providing very high wall or ceiling insulating values, though we did not take that approach on this building.

Log slab siding being stained

Since a contractor who was not properly educated completely ruined the in-slab floor radiant heating system by an improper installation , the owners have resorted to portable electric heaters to keep this building habitable in winter.

See RADIANT HEAT FLOOR MISTAKES

Despite very cold Minnesota temperatures, that tight construction and a good insulation job (by the same contractor) lets the owners heat the cabin to comfortable temperatures using several portable electric heaters.

Our photo at left shows test-color staining in progress on a section of log slab siding before installation on the cabin.

Good practice coats both sides and all edges of the cabin siding with a preservative stain before the siding is nailed in place.

From the exterior log-slab sided buildings look like a log cabin or log structure and, depending on the choice of designs, can even include protruding overlapped logs at corners as a cosmetic detail.

That detail was not included on the log cabin shown in our photo above.

Comparing the Insulation Value of a Solid Log Home to a Conventionally Framed Home

A 6-inch fiberglass frame wall has an "R" value of about R-19 while a 6" log solid wood wall has an "R" value of about 1 per inch or about R-6 in insulating value.

When a solid log wall is built using logs rounded on one or both exposed sides, the nominal log diameter does not give an accurate estimate of the wall's insulating value. That is because portions of the wall are constructed at a thickness less than the full log's diameter. The average wall thickness should be used to calculate the "R" value of a solid log wall when rounded logs are used.

More about insulation and thermal mass in comparison with traditional solid log homes is
at LOG HOME WALL INSULATION VALUES.

Thermal Mass of Solid Log Homes Compared with Insulated Wall Wood Structures

While the "R" value of a solid log home is almost certainly less than that of a modern conventionally-framed stud wall home insulated with fiberglass or other products, the wall "R" values alone do not accurately describe the comfort level of a log home. Provided that the log construction has been well-built without drafts or leaks, the thermal mass of solid log walls is considerable.

A large thermal mass in any building tends to make temperature changes occur more slowly than in structures lacking that feature. As a result, occupants of solid log homes often assert that they find their building very comfortable in both heating and cooling seasons.

Also see THERMAL MASS in BUILDINGS.

...

Continue reading at LOG HOME CONSTRUCTION or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

SLAB SIDING LOG HOMES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING STRUCTURES

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Questions & answers or comments about the design, framing, construction, & maintenance of slab log sided homes.

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.


Comment Form is loading comments...

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.

In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT