Large Capacity Water Storage Tanks, Selection & Use Guide

Large water storage tanks: why & when should you install extra water storage capacity at your building? What does the presence of a large water storage tank tell us about the flow rate or yield of a private well?

This article describes the use of extra or large water tanks to store additional water at properties with intermittent or limited water supply from a low-flow-rate well or intermittent municipal water supply.

The large indoor water storage tank shown at page top was contributed by reader Craig Revill and was found in a home that was 80-100 years old. We calculated the water tank volume at about 450 gallons.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?





ADVERTISEMENT





Large Water Storage Tanks, Why They Are Used, What They Imply about Well Recovery Rate or Well Yield

Apple juice storage tanks, Ductchess County, New York (C) Daniel Friedman

What does it mean if you see a huge water storage tank at a property?

Can we use additional water storage tanks to overcome a well that has a very slow recovery rate or a poor well flow rate? Yes we can, with some warnings.

Above we illustrate a huge liquid storage tank observed in Dutchess County, New York. This tank was used for apple juice storage: New York's Hudson Valley.

Very large water storage tanks, such as the one whose end is visible in the two photographs below are from two different properties, and are likely to indicate that the flow rate of the well serving the property is very slow, even inadequate by contemporary standards.

We've found these old steel tanks at older properties in the Northeastern U.S. in situations where the well flow rate, the rate in gallons per minute at which the well can give water over a sustained period, to be very low, perhaps around one gallon per minute or less.

Photograph of a storage type steel water tank

Very low well flow or well water delivery rates in the 2.5 gpm range or below, simply can't keep up with the rate of water usage in a building during normal occupancy.

Photograph of a storage type steel water tank

Large water tanks may indicate that the well flow rate can't keep up with demand

Worse, if we have only a typical water tank installed, say a 30 or 40-gallon unit, that tank is designed to smooth the flow of delivery of water to the building as the pump is turned on and off.

A small water tank is not sized to actually store a reservoir of water for the building. So if our well flow rate is very low, the building will simply run out of water and occupants will have to wait, perhaps hours, for the pump to re-fill the water tank.

Multiple smaller water tanks may also mean that the well flow rate is poor

Multiple water tanks (C) Daniel Friedman

A more modern solution to poor well flow rate is to install a cascade of two or more individual water pressure tanks in order to provide a larger volume of water stored at a property.

A low flow rate well and pump may rely on "recovery" overnight or over many hours

So a common solution for a low-flow-rate well is the installation of a very large water reservoir.

At older properties the single water tank may have been 1000 gallons or even more.

With a large water tank or multiple water tanks installed to provide this water storage reservoir, the well flow rate can be terrible but the building occupants won't see its effect since they're working off of the water storage tank.

At a low-flow-rate well installation the pump will be designed to run at a slow pumping rate so that the well water flow-rate can keep up with the pump as the pump sends water to the water storage tank.

The building occupants use water out of the tank and the tank and well and pump recover their water slowly, perhaps overnight.

Low flow rate wells or slow recovery rate wells at modern properties use a cascade of water tanks

At newer properties this same approach may be taken to "solve" a low-flow well but instead of a single huge steel tank such as the one in this photograph, the plumber will install a series or cascade of from two to perhaps four or five smaller water storage tanks of perhaps 50 gallons each.

If you are looking at a property and see that it has five new shiny blue and pretty big water tanks lined up in the basement you can guess that the well is marginal in its delivery capacity.

Low flow rate slow recovery rate wells have a questionable future life expectancy

A final warning about low-flow rate wells: because in many areas water is flowing into the well through cracks in rock below the surface, and because we're starting with an already low recovery rate well, the future ability of the well to give water at all must be questioned.

If local water is heavy in minerals, for example, the minerals tend to clog up those rock cracks over time, gradually reducing the water flow-rate into the well still further, until eventually it just stops working.

So a very large water storage capacity at a property is an indicator of both a low-flow-rate well (poor well recovery rate means the same thing), and an indicator that the future usability of the well at all must be questioned. We explain how people determine the necessary water tank size and volume

at WATER TANK SIZE & VOLUME .

Large Open Water Storage Tanks

Gravity fed water systems or pump-up rooftop systems with and without pressure-boosting pumps and water tanks

Sketch of open top water storage tank and well design used both on rooftops and in rural areas.

Still More Water Storage Capacity: Rooftop Water Tanks or Free-standing Water Storage Tanks at Ground Level offer increased water storage to mask the effects of an intermittent or slow-recovery water source.

Rooftop water tanks in urban areas such as New York City may be used to supply water at high pressure to the building below.

Water is pumped to the rooftop tank from its municipal source, then redistributed at good pressure to the points of use in the building below.

When passing through New York City, look at rooftops and you'll often see these tanks still in use. This sketch shows how a rooftop tank might be constructed, though this particular sketch has the tank next to a well.

Details about rooftop & tower - mounted water tanks are

at ROOFTOP WATER TANKS

Also see related details at CISTERNS, WATER STORAGE.

Water Quality Concerns when using a Rainwater Water Storage Tank

Moved to SAFETY & SANITATION of CISTERN WATER / RAINWATER - for drinking, bathing, other uses

 

...




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

Why do I see 600 gallons of water stored in my basement?

Why would there be two 300 gal plastic water storage tanks in my basement other then storage? Could it be a fix to something problematic? - JD 9/30/12

Reply: probably a well with a very poor flow rate

JD,

When we see very large on-site water storage at a private house we figure that the ability of the well to deliver water, its flow rate or recovery rate, is very very minimal - someone installed large water tanks intending that the pump and well fill those tanks very slowly, over time, including when no one is using any water (at night when you're asleep for example) so that when you need water there is some stored in the tanks.

What this means to you is that your well is not very effective and you may need to address that problem soon.

 

How often do I need to clean a large water storage tank?

What is the best material to use if one is to store up to 3000 or more gallons of water above ground for a long period of time.

Approximately 6 months. I plan to build a separate structure to store my water tank and I don't want to have to have it constantly filled by delivery.

Even though I will have drainage coming through filters and a reservoir installed inside the house to help insure clean water; I'm concerned about the quality of water stored for a period of time. I also notice someone asked the question regarding cleaning.

Based on size and type of tank, how often should this be done.

I will be living off the grid in Southern Colorado and it is more economical for me to use a cistern instead of drilling a well. On 2018-09-11 by JB Silver -

Solution by (mod) -

I think that plastic or fiberglass are durable and avoid long-term rust and corrosion problems but of course need to be anchored and supported.

Any large tank needs to be able to be emptied, cleaned, disinfected. The tank manufacturers typically advise annual or semi-annual cleaning - a step that in my experience almost nobody follows - until they have a problem.

At ROOFTOP WATER TANKS - WATER TANK CLEANING REQUIREMENTS you'll see that cleaning is required by local and model codes.

In that article you'll find live links in this text:

Rooftop Water Tank Cleaning: rooftop water tanks require periodic cleaning and disinfection.

See ROOFTOP WATER TANK CONSTRUCTION STANDARDS & REFERENCES

in ROOFTOP WATER TANKS

Also see CLEANING & DINSINFECTING WATER CISTERNS AFTER FLOODS & HEAVY RAINS [PDF] U.S. CDC

Having trouble repairing a gate valve on a 5000 gallon water tank

Water control valve type (C) Carson Dunlop AssociatesI have a 5000 gal water storage tank on a hill next to my house used for irrigation. It has been in operation over 20 years with no problems.

Two weeks ago, the water output began to diminish and now there is no flow at all. There are two faucet outlets in the pipeline line down the hillside and a final faucet at my house.

There is no water flow at any of the faucets which means any blockage is probably at or near the gate valve outlet of the tank. The outlet piping is 2 1/2 to 3 inch pipe out of the tank and into the ground.

I assume that thereafter the piping is reduced to 1/2 inch - but have not dug it up to look - if the assumption herein are correct, my question is how does one screw the gate valve out of the line to be able to clean out any blockage? after the tank is empty of course.

or does some one have to actually climb into the tank? (June 3, 2014) louis

Reply:

Normally you would not have to enter a tank to remove a valve that serves as an outlet control. It would be installed from outside the tank, into a tapping.

A gate valve has a removable top that can be loosened to disassemble the valve for cleaning or repair.

Details are at PLUMBING CONTROLS & VALVES 

Adding a large 2500 gallon water storage tank to my existing system: do I need a booster pump?

I’m adding a 2500 gallon water storage tank to my existing system. I am on a well, with a pressure tank and currently have good water pressure.

Will I need to add a booster pump or larger pressure tank when I plumb in the water storage tank.

My plan is to fill the tank during the day when my solar is at its peak and draw from it when I irrigate in the mornings. I’ll be the first to admit that I am no expert in water systems. On 2017-11-25 by Ron Hughes

Answer by (mod) -

You may not need a booster pump I don't know enough about your application to say.

For example, if your large water storage tank is above or at the same level as your present water pressure tank, you would not expect to need a "booster pump."

Watch out: with or without a booster pump if you try to fill that 2,500 gallon water storage tank in one continuous operation, if your well cannot support the continuous pumping rate, that is if the pump rate in GPM exceeds the flow rate of your well in GPM, you will exhaust the well and you risk damaging the pump too.

I would start by looking at the flow rate of the well. That will tell you how much time you need to allow for filling your water tank and also it will tell you the safe pumping rate.

More guidance about using a big water tank and why one might do so is at LARGE CAPACITY WATER STORAGE TANKS

Also see WATER PRESSURE BOOSTER PUMP - Daniel F.


...

Continue reading at WELL YIELD IMPROVEMENT or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

LARGE CAPACITY WATER STORAGE TANKS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS & SPRINGS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Share this article:

Search the InspectApedia website

Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.

Citations & Reviewers

In addition to any citations in the article above, a full list is available on request.

  • Access Water Energy, [Name may have changed to Access Energy and/or to Quality Energy - Ed.] PO Box 2061, Moorabbin, VIC 3189, Australia, Tel: 1300 797 758, / 13 0088 0188 ? email: sales@accesswater.com.au Website: [Dead website 20026/09/02 - appears active via Linkedin.com at https://www.linkedin.com/company/accesswater/home/

    Moorabbin Office: Kingston Trade Centre, 100 Cochranes Rd, Moorabbin, VIC 3189

    WAS and might be under another name, an Australian supplier of: Greywater systems, Solar power to grid packages, Edwards solar systems, Vulcan compact solar systems, water & solar system pumps & controls, and a wide rage of above ground & under ground water storage tanks: concrete, steel, plastic, modular, and bladder storage tanks.
  • Amtrol - AMTROL, Inc., Corporate Office, 1400 Division Road, West Warwick, R.I. 02893 USA Tel: (401) 884-6300
    Fax: (401) 884-4773 The company's website is at www.amtrol.com; also see

    Amtrol's Well-X-Trol WATER PRESSURE CONTROL TANK INSTALLATION & USE INSTRUCTIONS [PDF]
  • Campisano, Alberto, and Carlo Modica. Optimal sizing of storage tanks for domestic rainwater harvesting in Sicily [PDF] (at sciencedirect.com) Resources, Conservation and Recycling 63 (2012): 9-16.
  • Fewkes, Alan. "Modelling the performance of rainwater collection systems: towards a generalised approach." Urban water 1, no. 4 (2000): 323-333.

    Abstract excerpt: The collection of rainwater from roofs, its storage and subsequent use make a significant saving in the use of potable water. 
  • Graham, Jay P., and James VanDerslice. The effectiveness of large household water storage tanks for protecting the quality of drinking water [PDF] (2005) (at IWA Publishing) Journal of Water and Health 5, no. 2 (2007): 307-313. - local backup saved as Large-Water-Tank-Water-Quality-Campisino.pdf
  • Ludwig, Art, Water Storage: Tanks, Cisterns, Aquifers, and Ponds for Domestic Supply, Fire and Emergency Use - Includes How to Make Ferrocement Water Tanks, Art Ludwig, Oasis Design (May 30, 2005), ISBN-10: 0964343363, ISBN-13: 978-0964343368, Quoting:

    A do-it-yourself guide to designing, building, and maintaining water tanks, cisterns and ponds, and sustainably managing groundwater storage.

    It will help you with your independent water system, fire protection, and disaster preparedness, at low cost and using principles of ecological design. Includes building instructions for several styles of ferro cement water tanks.
  • Manga, Musa, Timothy G. Ngobi, Lawrence Okeny, Pamela Acheng, Hidaya Namakula, Elizabeth Kyaterekera, Irene Nansubuga, and Nathan Kibwami. "The effect of household storage tanks/vessels and user practices on the quality of water: a systematic review of literature." Environmental Systems Research 10, no. 1 (2021): 18.
  • Schafer, Cynthia A., and James R. Mihelcic. Effect of storage tank material and maintenance on household water quality [AWWA Journal] Journal‐American Water Works Association 104, no. 9 (2012): E521-E529. - local backup copy saved as Water-Tank-Water-Quality-Schafer.pdf
  • Vogel, H., Thanks to aerospace engineer Herman Vogel, July 2010, for providing an update on High Density Polyethylene HDPE storage tanks for water, chemicals, waste oils, etc.
  • World Health Organization 2004 Guidelines for Drinking-water Quality. 3rd edition, (Available at http://www.who.int/entity/ water_sanitation_health/dwq/GDWQ2004web.pdf) WHO, Geneva.
  • In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested

    CONTINUE READING or RECOMMENDED ARTICLES.


ADVERTISEMENT