How to Add Air to a Water Pressure Tank by Draining
Add air to water pressure tank:
This article describes how to restore lost air in a building water pressure tank using a garden hose and gravity in a building water supply system where a private well is the
water source.
This procedure is used as a simple means to correct water pump short cycling when the cause is a water-logged water tank.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
Method 3 for adding air to the water tank: Use Gravity to drain the tank and then to let air in
Here we explain a most basic way to get the proper air charge back into the water pressure tank and thus to stop well pump short cycling.
Article Contents
...
Is the Water Tank Waterlogged? Rocking the water pressure tank
(Gently) If the water-containing rubber bladder in a "captive air" water tank is defective (it can become stuck to itself and remain collapsed), the result can be a rapid on-off short cycling of the water pump.
We test water pressure tanks to see if they're empty or nearly empty of water by seeing if we can rock or move the tank. If the tank is heavy with water it does not move easily.
Watch out: Be careful not to jiggle and break a pipe!
Readers of this document should also see WATER PUMP REPAIR GUIDE an specific case which offers an example of diagnosis of loss of water pressure, loss of water, and analyzes the actual repair cost.
The illustration at page top is courtesy of Carson Dunlop, Inc. in Toronto.
The photograph shows a typical water tank with
controls located near the tank bottom.
Key to the Numbered Items in the Well and Pressure Tank and Controls Photo Shown Here
Clicking on this photo shows an enlargement of the blue-handled drain valve
that might be used to drain all of the water out of this tank in the "gravity procedure" we discuss
below. In this particular photograph, you can see lots of water system components that can be identified:
- The well casing top -
the rusty round disk on the floor to the front right of the gray water tank, with
a black plastic supply pipe leaving the well casing. The upside down "U" shaped little copper pipe also leaving the
well casing top is an air vent to let air into the well during the pumping cycle.
- The piping from well casing to water tank
which in this case goes from black plastic at the well
to galvanized pipe to the pump control switch (gray box) to copper into the bottom of the water tank.
- An air vent on the well casing top
- A chemical injection system connector on the well piping, probably a chlorine disinfectant system
- Electrical wiring to and from the pump pressure switch -
the elecgrical wire brings power to one side of teh pump pressure switch and the second wire leaving the switch, while harder to follow, routes around behind the water pressure tank and at the other 5 at right in our photo, brings electrical power down to the well pump.
- The water pump pressure control switch -
the gray box with wires to and from it, connected on
the piping between the well and the bottom of the water tank.
- Watch out: Water leaks
are present as the floor is wet around this equipment.
- A water shutoff valve
(orange handle) that, if closed, will stop water from entering the water pressure tank.
Watch out: this is an improper installation because as plumbed, closing this valve will remove the pressure tank from the system while leaving the pump pressure control switch still active on the well line: this would lead to rapid short-cycling when water is run, risking damage to the well pump and pump control switch.
Here is a close up photo showing
both dwhat is proabably a blue handled drainn valve a next to that orange handled shutoff valve.
- A water shutoff that will turn off water supply into the building: this valve is just "past" the pump pressure control switch (in the direction of water flow this valve is "after" or "past" the pressure control switch)
- A water pressure gauge
- Unclear in the photo: either another shutoff valve or a drain valve on the building water line
- The bottom of a water treatment device,
probably a chlorinator can be seen at the right of this photo
The black-bottomed
round container and next to it a solid black container may be a combination water softener and chlorinator or just a chlorination system.
We suspect this because we see a small diameter plastic tube connected on a tee in the black plastic line leaving the well casing top. This
is typical of a chlorine injection system used on bacteria-contaminated wells.
- The water pressure tank
- (Not visible) Where's the actual well pump?
We can't see it in this photograph, but at step 5 we see wiring going into the well casing so we know at this installation the water pump is a submersible pump that is inside the well casing.
On your water supply system these components may not all be present and they may be at different locations.
Bladder type or captive-air water pressure tanks and their repairs are described in more detail at WATER TANK TYPES.
...
Add Air to a Water Tank by Draining: Step by Step
You'll need a garden hose. That's about it, but read all of these instructions
through before starting this project
The procedure just below is most suitable for a bladderless steel water pressure tank.
Watch out: to be sure that the air charge in a water pressure tank is at the proper level, always set or check the air pre-charge pressure when there is no water pressure in the system and no water pressure in the water tank.
Using the method on this page we're going to drain all water and all pressure out of the water pressure tank, and in this case after the tank has drained, the completely-empty bladderless water tank will be at atmospheric pressure (or zero on your pressure gauge). We do NOT need to pump additional air into the tank using this method.
- Use the bathroom
if you need to, while you can still flush.
Then run and save some water into a container for drinking
or other purposes (see "Warning, Loss of Pump Prime" below)
before starting this procedure, just in case you get into trouble. A few gallons is more than
enough for most situations.
- Turn off electric power to the water pump.
In this photo the thoughtful prior owner has
marked the electrical switch above and to the left of the water tank with the word "WELL" so we figure this is probably
the electrical switch to turn off the water pump.
Turn this switch off now. Do
this at the electric panel if there is not a special switch for the pump
located nearer the water pressure tank.
Note about the main and other water shutoff valves: you don't have to open or
close any other shutoff valves at the tank to follow this procedure. This is
great since these shutoffs, seldom used, often don't work anyway.
But if the
drain valve at the bottom of (or near the bottom of) the water tank is
old, stuck, damaged, or otherwise inoperable, you may want to revert to methods
#1 or #2 above until you can ask a plumber to replace the drain at the bottom of the
pressure tank.
- Attach a garden hose to the tank drain.
The water tank drain valve is usually
located at or near the front bottom of the water tank itself, and it looks just like an outdoor or
laundry faucet except you have to bend over and fiddle around to get the
hose attached since it's down near the floor.
The tank drain will always be
located at the bottom of the tank. Don't
get mixed up with some higher faucet somewhere else or this method won't work.
If there is a floor drain near the tank you
can simply drain the tank to that drain, but watch out! Often these drains are
clogged. Don't have a basement flood; have a garden hose handy to drain to
outside if needed.

In the above photo, the long handle marked "water" is the water shutoff between the water
tank and the rest of the building. When this valve is at right angles to the
direction of the water pipe, that shutoff is "off".
We leave it open (parallel to the pipe, as you see it here) for this
procedure so that air can get into the tank from a nearby open faucet in the building.
In this photo the round black handled valve marks the water tank drain to which
you will attach a garden hose.
The small brass fitting to the right of the black
drain valve is a pressure relief valve needed on any pressurized tank.
The water pressure gauge is also visible in the center of this photo as is the blue base of our
water tank in the background. On your water system these components may be
located differently.
Run the other end of the garden hose outside and
to a location where the end of the hose will be lower than the tank drain.
After all eventually we're going to be relying on gravity and water does not
run uphill.
- Open the water tank drain faucet.
Shortly you should see water running out of the other end of the hose.
- Let air into the tank.
Eventually water will
virtually stop running out of the hose. But if all of the fixtures in the building are
turned off there may be no easy path for air to flow backwards through the plumbing and
into the water tank. So water may still remain in the pressure tank. If you push (gently!) on the water tank you may discover that it still is heavy - containing water.
(Don't wiggle the tank all over the
place or you might cause a pipe to leak.) Now water is barely running out of
the hose because no air can get into the tank. It's like holding a full soda bottle
upside down - air has to work to get in past the water gurgling out. In this
case air would have to bubble all the way in up through the garden hose. We'll
meet our maker before this will ever happen.
So here are some ways to get air
into the tank, arranged in order of preference:
- Use that Schrader Valve:
Once no pressure is left in
the tank, since you have a Schrader valve on the tank you can just press the
little valve pin in the center of the valve. You might get a little squirt of water.
This means the tank is still under pressure.
Wait a few minutes then try again.
Once there is no pressure in the tank the valve stem will stay pressed down and
you'll hear air hissing and bubbling into the tank. Isn't this just the
neatest thing? You could speed things along with a bicycle pump but it's not
necessary.
- No Schrader valve? or in a hurry? open a plug which might be found on the water tank top or center of the side
of the water tank.
This works fastest but has
several risks: it's hard to get this plug out and in doing so you might jiggle
the tank so much you cause a pipe leak nearby. And if you don't have pipe
sealant or Teflon tape you may have trouble getting the plug back in and
absolutely tight. If the plug leaks you're worse off than before we started. I'd
hold this idea in reserve for systems without a Schrader valve.
- No Schrader and No Plug?
Open other plumbing fixtures in the building: at a nearby sink, for example.
This step can speed things along, depending on
how pipes are routed. Opening a nearby fixture valve gives an easy path for
air to enter the tank.
Remember to close these fixtures up
before turning the water back on. If you forget to close open fixtures you'll either
hear them running when the pump is turned back on, or you'll notice that the pump
just runs and runs when it's turned on.
Also, as a general warning, if you find any building
water control valves hard to
operate, leave them alone or you may cause a leak, or you may open the valve and
be unable to close it later. Older, unused valves are often best left alone
until you have a plumber and spare parts readily at-hand.
- When to stop letting air into the tank -
gravity
method: Using this "gravity method" you simply let ALL of the
water out of the tank. Once air is hissing and bubbling into the tank and
water is gurgling out of the garden hose you're nearly home free. Just let it
run until nothing is happening.
You can't make a mistake since any excess air
will be automatically purged later when you run various fixtures.
- Close the tank drain and remove the garden hose.
Also close any other valves or fixtures you may have opened
in the building.
Warning about loss of pump prime:
in a few instances, draining the water tank can also drain water out of the
pump itself - if the pump is inside the building. Some (indoor) water pumps, if drained dry, won't be able to lift
water back into the system.
Such pumps need to be re-primed. This is a use for that water we told you to run and
set aside before beginning your project.
Pumps that need to be primed will have a fitting (or a simple pipe plug) atop the water pump
housing itself that is opened, and into which pump priming water is poured until this chamber is filled - usually a
quart is about enough to refill the pump. This is never a problem with submersible (in-the-well) water pumps.
- Turn electric power
to the well water pump back on.
- Check for leaks:
Walk calmly back to the water pressure tank and listen and watch for leaks.
- Water Leaks Found:
Is water squirting all over the place?
- It is? Remain calm.
It's just water. Humans are mostly made out of water anyway. If the leak is significant,
turn off electric power to the water pump, using the switch at the pump ONLY if you're not also standing on a wet floor.
If the floor is wet, go to the electric panel and turn the pump off there.
- Water tank drain valve leak:
If it's leaking from the tank
drain try closing it off more tightly. If it won't stop leaking there you need
to turn off the electric power once again and go out to
buy a garden hose
end-cap to screw over the tank drain so you can use the system while
waiting for a plumber to replace the drain valve washer or parts. Don't' forget
to get a hose washer to fit inside the garden-hose cap or the cap will leak
too.
- Water tank Schrader valve water leak:
If water is leaking
from the Schrader Valve try just pressing the valve tip down and releasing it a
couple of times. This will usually re-seat the valve stem and leaking will
stop. If this doesn't work,
borrow a valve stem cap from your car and
screw it over the Schrader valve end to stop the leak. This will let you use
the system until a plumber can replace the valve stem core or replace the
valve.
- Other water leaks: if water is leaking from
somewhere else you did something we didn't anticipate and you'll need to shut
off the system and call me or call a plumber.
- Air leaks in the plumbing system:
Is air hissing out of somewhere?
- Remain calm. We can fix this too. After all, humans breathe air. It's not so bad.
- Schrader valve air leak:
if air is leaking out of
this valve follow the Schrader valve water leak procedure just above. You might
have to jiggle the valve stem a few times or wait a full minute then try again.
This almost always works. If not use a tire valve cap to close off the leak as
described above.
- Air volume control air leak:
If air is hissing
out from the air volume control you can almost always stop it by pressing a
finger a time or two for a few seconds or more atop the leaking hole.
You
can find the hole buy simply feeling for where air is squirting out. The
back pressure created when you press your finger over the leak will often clean
and re-seat the little valve in this device. If this doesn't work you might try
just letting the tank fill up with water to see what happens.
No big flood is going
to occur. If water keeps on leaking out of the tank you'll need to shut off the
electric power and call a plumber to replace the valve. (A rare requirement.)
I hate these AVC's anyway as they so often are worthless. On my systems if the
AVC gives me trouble we take it off and throw it away, screwing a plug into wherever
it was mounted. So there!
- Air leaks at plumbing fixtures in the building:
using this method we've put a lot of air into the pressure tank. When the pump
first comes on some air will be pushed up into the building piping.
Don't
worry, it won't hurt a thing. B
ut when you first run water at various
fixtures some air may come squirting out with the water. This problem will
correct itself as soon as you've run a minute or so of water at the offending
fixture. Don't worry, it's normal.
- If air is leaking out of
somewhere else I'd love to hear about it, as we can't imagine what you did. You may try waiting a few minutes to see if it
stops. In worst case you'll have some water spillage and you'll need to call a
plumber.
- That's it. You've finished restoring lost air from the building water supply pressure tank!
...
Procedure for Fine-tuning Bladder-type Water Tank Air Pressure
This alternative method for fine-tuning the air pressure setting in a water pressure tank was suggested by reader Mark Caruso. CONTACT
us to suggest changes and additions to this water tank procedure.
Watch out: The water tank air pressure adjustment described below is only suitable if your water tank is already working normally and if there is no evidence of a waterlogged pressure tank, significant water pressure tank air loss, or
a SHORT CYCLING WATER PUMP.
Note that adjusting the water tank air pressure is not a substitute for adjusting the water tank pressure control switch discussed
at WATER PRESSURE CONTROL SWITCH ADJUSTMENTS.
The pressure control switch sets the cut in and cut out pressures of the water supply system. The proper volume of air in the pressure tank avoids short cycling of the water pump as we discuss beginning
at SHORT CYCLING WATER PUMP.
Mr. Caruso's alternate idea for fine-tuning a non-waterlogged water pressure tank air charge includes these four simple steps:
- Close off all plumbing fixtures
that are using water in the building.
- Turn on the water pump
and let the system run until the water pump turns off (the system water pressure has reached the "cut out" pressure set on the pump control switch).
- Open one or more plumbing fixtures to drain the water pressure in the system;
during this draining, monitor the air pressure;
note the air pressure at which the water pump restarts – this calibration tells you approximately the current pump cut-in pressure setting as measured with your water tank pressure gauge. We say "approximately because pressure gauges are not precise and sometimes give very inaccurate readings.
See WATER PRESSURE GAUGE ACCURACY.
- Use this calibration setting minus 2 psi
to charge the water tank air bladder following the procedure described
at WATER TANK BLADDER PRESSURE ADJUSTMENT
Bladder type or "captive air" water tanks do not normally need to have makeup air added, and water pressure or short cycling problems with bladder-type water tanks are usually traced to a failure of the bladder itself - a component that may be replaceable.
See WATER TANK BLADDERS & CAPTIVE AIR.
...
ADVERTISEMENT
Reader Comments, Questions & Answers About The Article Above
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
What's causing a hissing sound coming from my well?
There is a hissing sound coming from my well, and the submersible pump is brand new, and the power is turned off to the well pump. What is causing this? - Candace Hanscom 11/25/11
Reply:
Candace, hissing may be air being vented inside the well from a snifter valve. We explain the snifter valve
at WATER TANK AIR VOLUME CONTROLS - or you can search InspectAPedia for "How to Find & Repair the Water Tank Air Volume Control Device" to read more about that device.
Bladderless water tank becomes waterlogged quickly after draining
I have a bladderless tank which rapidly becomes waterlogged after draining. I drain it completely using a hose (the tank is placed very high) - that is, until no more water comes out (and I have opened house faucets to let air in). Immediately after this, the short-cycling is much better (pump running 15 seconds not 1 second) but within a day short cycling starts again. I suspect I have water trapped in the tank but I'm reluctant to remove the top plug from the tank in case I damage things. No Schrader on the tank. Paul Adams 5/14/12
Reply:
Paul,
If all piping connections to your water tank come off of the bottom of the tank it can be quite difficult to fully drain all water out of the tank at it's bottom. For example if draining the tank through a garden hose, air movement back up the hose, or from other house piping can be agonizingly slow. One needs patience and hours, or a way to allow or even to push air into the tank so that it cn drain fully.
If the tank remains heavy it still contains quite a bit of water.
Options for the case you describe are to open a tap at the tank top, being prepared to clen up and reseal that connection, or to drain via the tank drain valve right at the tank, not through a hose, or to push air into the tnk using a pump or can of compressed air connected to a schrader valve found on or added to the tank
If the high or top plug on your tank is removed, using an appropriately sized adapter bushing, yo could install an air valve there.
You should be seeing a longer drawdown cycle.
Thank you to our readers for their generous comments
Thank you very much for the guide. I've found it extremely helpful. Easily the most helpful guide online.
You guys have just made my life so much easier. I've building air pressure in my tank up to 28 psi for years because I thought that was the correct procedure. Turns out I have a bladderless tank so I've been spending way too much time an effort on this task. Thanks!!!!
To the creators and maintainers of Inspectapedia. Your resource and instruction made possible the repair and function of my well Pump/pressure tank
possible, Thank You!
...
Continue reading at WATER TANK AIR HOW MUCH TO ADD or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
WATER TANK AIR ADD BY DRAINING at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & References
In addition to any citations in the article above, a full list is available on request.
- Thanks to reader Mark Caruso
for discussing alternative methods for fine tuning the water pressure tank air pressure setting - July 2010
- In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
CONTINUE READING or RECOMMENDED ARTICLES.
ADVERTISEMENT