Well water pump diagnostic FAQs set #7.
If the well pump runs too often, is noisy, seems weak, runs intermittently with no apparent reason, or is otherwise misbehaving, these questions will help sort out what's wrong.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
These questions & answers about well pump diagnosis and repair were originally posted at WATER PUMP REPAIR GUIDE - home. Be sure to review the diagnostic and repair help given there.
Also see our index to all water / well pump diagnosis and repair FAQs at WATER PUMP REPAIR FAQs
...
My well pump is jammed how i diagnose what has happened ? How i repaire it by proper person at reasonable cost ?
2018-03-15 by Jyoti purohit,Nagpur
Answer by (mod) -
JP
If the pump problem is a damaged impeller assembly it may be economical to replace that part of the unit.If there is an electric motor repair shop near you, take the entire pump assembly in and ask for a diagnosis of the problem.
I fell with my waterpump in water...yesterday and now it wont start....what could be the issue.... coz yesterday it was running normally..On 2018-01-30 by Nelson
Answer by (mod) -
Not-really-Nelson
Most likely you wet the pump motor interior and connections. That in turn short circuits electrical components, windings, switches. Even when the pump is dry it may be damaged and unsafe and would probably have a shortened remaining life as its components that got wet will also corrode, jam, or short.
Failure of well pump that was flooded during the hurricane
My water wer went through Harvey under 5 feet of water. Has been running great since then till tonight. Loose all water pressure and stmt outside and the well smelled like brunt wiring. Shut off the breaker to it. Not sure what to do now. On 2018-01-30 by Denise Guthrie
Answer by (mod) -
Denise
Yes, unfortunately, electric motor failure after the motor has been flooded can sneak up on you. A motor that has been submerged by Harvey or any other source of flooding might dry out and run apparently with no problem for some time.But any electric motor that has is not specifically designed to run "under water" and that is soaked or submerged is going to fail eventually. The moisture inside the motor leads to corrosion, break-down of insulators, damage to motor bearings, loss of lubricants, damage to electrical capacitors, and sooner or later, a motor failure.
At this point the motor and any other electrical components (like switches or pressure controls) that were wet should be replaced.
Watch out: in addition to a motor or control or switch failure after flooding, such components are unsafe, as some failures could result in a risk of electric shock, injury, or worse to someone touching the equipment.
Continue reading at WATER PRESSURE PROBLEM DIAGNOSIS TABLE for table listing causes & cures for well pump or water pressure problems, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
...
WATER PUMP REPAIR FAQs-7 at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.