Textile Septic Media Filters for Effluent Treatment
Using textile medial filters for septic systems:
Media filter septic systems use a conventional septic tank followed by any of several methods to further filter and treat septic effluent before it is discharged to the soil, soil surface, or waterway.
This page defines and describes the design and use of textile or fabric as a septic media filter for effluent treatment in onsite wastewater systems.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
When using a septic media filter system, effluent treatment is by both actual filtration and ultimately by a biochemical process as the filter "matures" and includes its own biomass. Both natural media filter septic systems (such as sand, gravel, or peat) and synthetic media filter septic systems (foam cubes, glass, slag) are used, and both single-pass and effluent recycling systems may be employed.
Geotextiles are often used in septic effluent media filter systems; they can provide a large surface area and high water volume retention.
Fabric media is cut into squares and placed into a container, or hung in curtains in a container. Textile filters operate in a recirculating mode similar to that discussed above, but offer this advantage over sand and peat media: the larger effective surface area of the synthetic textile permits a much higher loading rate in gallons per square (or cubic) foot, thus permitting the media system to be designed into a physically smaller package.
Watch out: some septic system designs use fragile media or media filters for which service should be performed only by properly trained or certified septic service companies. Failure to properly protect media or filters from damage during septic tank pumping or cleaning can cause costly damage to the system and may prevent its proper operation.
See BAT MEDIA SEPTIC PLANTS and the owners' manual provided by Jet Inc. for that system design.
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
What do you think of the ez flow system ? by the way, this site is so informative & helpful to me. thank you so much - William
William I've added the article category SEPTIC SYSTEM DESIGN ALTERNATIVES
wherein you'll see MEDIA FILTER SEPTIC SYSTEMS are discussed, specifically in the article
titled "TEXTILE FILTERS" .
The EzFlow septic system is a media filter approach. Properly installed the system has the appeal of simpler, lower installed cost. I expect that to handle the same effluent volume as a conventional gravel trench you may need more linear feet of filter media, installed either in parallel in the same trench or end to end in a longer trench; but then the installation is still simpler.
Does a media-wrapped drain pipe in a gravelless system last as long as a gravel-filled trench in a conventional drainfield, given all other factors being the same? I don't know.
OPINION: I have not seen data on system longevity comparisons among most of the alternative septic system designs, but my field and research experience leave me convinced that in any system the success or failure of the system depends largely on how properly it's installed.
Contact information for Infiltrator Systems and a link to the product description spec sheet for EzFlow septic system components are found
at SEPTIC MEDIA FILTER SOURCE LIST
...
Continue reading at TYPES of SEPTIC MEDIA FILTER MATERIALS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
TEXTILE SEPTIC MEDIA FILTERS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.