InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

STRUCTURAL INSPECTIONS & DEFECTS

ADVANCED INSPECTION METHODS
AGE of a BUILDING - how to determine
ARCHITECTURE & BUILDING COMPONENT ID

BARK SIDE UP on DECKS & STEPS
BASEMENT WATERPROOFING
BEST CONSTRUCTION PRACTICES GUIDE
BRICK FOUNDATIONS & WALLS
BRICK STRUCTURAL WALL Loose Bulged
BRICK WALL THERMAL EXPANSION CRACKS
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BUCKLED FOUNDATIONS due to INSULATION?
BUILDING DAMAGE ASSESSMENT & REPAIR
BUILDING SAFETY HAZARDS GUIDE
BUILDING SETTLEMENT

CARPENTER ANTS
CARPENTER BEES
CHIMNEY INSPECTION DIAGNOSIS REPAIR
COLD POUR JOINTS, CONCRETE
COLUMNS & POSTS, DEFECTS
CONCRETE FOUNDATIONS
CONCRETE FOUNDATIONS, PRE-CAST
CONNECTORS, FASTENERS, TIES
Cracks, Checking or Splitting Beams & Log Homes
CRAWL SPACES

DECK & PORCH CONSTRUCTION
DECK CONSTRUCTION BEST PRACTICES
  BARK SIDE UP on DECKS & STEPS
  Deck Beams & Girders
  Deck Piers & Posts
  Deck & Porch Connections: Ledger Boards
  Deck Framing Tables, Spans
  Deck Flashing at Building
  DECK FLOOR & STEP CUPPING
  Deck Board Gaps, Spacing Guide
  Deck & Porch Steps or Stairs
  Deck & Porch Railings
  Deck & Porch Products, Manufacturers
  Fasteners, Nails, Screws, Hidden, for Decks
  Fasteners/Connectors, Ties, Structural
  Porch Construction & Porch Screening
  Preservative-Treated Framing Lumber
  Rooftop Deck Construction
  ROT-RESISTANT Deck Lumber & Flooring
  STRUCTURAL DAMAGE PROBING
  Synthetic Deck Lumber: Composite, Plastic, Vinyl
DECK COLLAPSE Case Study
DECK FINISHES COATINGS PRESERVATIVES
DECK FLASHING LEAKS, ROT Case Study
DECKS, ROOFTOP CONSTRUCTION
DECK CONSTRUCTION BEST PRACTICES
DEBRIS STAINING on ROOFS
DEFINITIONS of Mobile Home, Doublewide, Modular, Panelized
DEFINITIONS of ENGINEERED WOOD OSB LVL etc
DEW POINT CALCULATION for WALLS
DEW POINT TABLE - CONDENSATION POINT GUIDE
DISASTER BUILDING INSPECTION & REPAIR

EARTHQUAKE DAMAGED FOUNDATIONS
EIFS & STUCCO EXTERIORS
ENGINEERED WOOD Flooring
ENGINEERED WOOD Products

FIRE DAMAGE vs MOLD DAMAGE

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOOD DAMAGE TO FOUNDATIONS
FLOODED HEATING EQUIPMENT REPAIR
FLOODED SEPTIC SYSTEMS, REPAIR
FLOODED WATER HEATER REPAIR
FLOODS IN BUILDINGS, MOLD PREVENTION

FLOOR, ENGINEERED WOOD & LAMINATES
FLOOR FRAMING & SUBFLOOR for TILE
FLOOR TYPES & DEFECTS
FLOOR TILE ASBESTOS IDENTIFICATION
FLOOR TILE HISTORY & INGREDIENTS

FOOTING & FOUNDATION DRAINS
FOOTINGS EXPOSED, Repair Methods

FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION CONSTRUCTION TYPES
FOUNDATION CONTRACTORS, ENGINEERS
FOUNDATION CRACKS & DAMAGE GUIDE
FOUNDATION DEFECTS OF OMISSION - MISSING
FOUNDATION FAILURES by TYPE & MATERIAL
FOUNDATION FAILURES by MOVEMENT TYPE
FOUNDATION INSPECTION METHODS
FOUNDATION INSULATION OPTIONS
FOUNDATION MATERIALS, Age, Types
FOUNDATION REPAIR METHODS
FOUNDATION SETTLEMENT
FOUNDATION WATERPROOFING

FRAMING DAMAGE, INSPECTION, REPAIR
FRAMING DETAILS for BETTER INSULATION
FRAMING DETAILS for DOUBLE WALL HOUSES
FRAMING CONNECTORS & JOIST HANGERS
FRAMING FASTENERS, NAILS, SCREWS, & HIDDEN
FRAMING & SUBFLOOR for TILE
FRAMING MATERIALS, Age, Types
FRAMING SIZE & Spacing, Age, Types
FRAMING TABLES, SPANS for DECKS

FRENCH DRAINS
FROST HEAVES, FOUNDATION, SLAB
FRT PLYWOOD

GALVANIC SCALE & METAL CORROSION
GLUES ADHESIVES, EXTERIOR CONSTRUCTION
GRADING, DRAINAGE & SITE WORK
GUTTERS & DOWNSPOUTS

HOUSE PARTS, DEFINITIONS
HOUSEWRAP INSTALLATION DETAILS

I-JOISTS, Wood Roof Floor
ICE DAM PREVENTION
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INSECT INFESTATION / DAMAGE

KIT HOMES, Aladdin, Sears, Wards, Others

LEAD POISONING HAZARDS GUIDE
LEED GREEN BUILDING CERTIFICATION
LOG HOME GUIDE
LVL Laminated Veneer Lumber, Beams

MOBILE HOMES, DOUBLEWIDES, TRAILERS
MODULAR HOME CONSTRUCTION
MOISTURE CONTROL in BUILDINGS

NOISE / SOUND DIAGNOSIS & CURE

OSB - Oriented Strand Board

PANELIZED CONSTRUCTION
PLASTER BULGES & PILLOWS
PLASTER, LOOSE FALL HAZARDS
PLYWOOD Roof, Wall, Floor Decks & Sheathing
PORCH CONSTRUCTION & SCREENING
PRE-CUT & KIT HOMES
Preservative-Treated Framing Lumber

RAILINGS, DECK & PORCH
RAILINGS, STAIRWAY
RETAINING WALL DESIGNS, TYPES, DAMAGE
RETAINING WALL GUARD RAILINGS
ROT, FUNGUS, INSECT DAMAGE
ROT RESISTANT LUMBER
ROT, TIMBER FRAME
ROT, TIMBER ASSESSMENT

SEARS KIT HOUSES
SEPTIC & CESSPOOL SAFETY
SHEATHING, FIBERBOARD
SHEATHING, Gypsum board
SHEATHING, OSB
SHEATHING, Plywood
SHEATHING, FOIL FACED - VENTS
SIDING TYPES, INSTALLATION, DEFECTS
SINKHOLES, WARNING SIGNS
SINKING BUILDINGS
SLAB CRACK EVALUATION
SLAB CRACK REPAIR
Splits in Structural Wood Beams
STAIN & BIODETERIORATION AGENT CATALOG
STAINS on & in BUILDINGS, CAUSES & CURES
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIRS, RAILINGS, LANDINGS, RAMPS
STONE CLEANING METHODS
STONE FOUNDATIONS
STONE VENEER WALLS
STRAW BALE CONSTRUCTION
STRESS SKIN INSULATED PANELS
STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES
STRUCTURAL DAMAGE PROBING
STRUCTURAL WOOD ASSESSMENT
SUMP PUMPS GUIDE
SWEATING (CONDENSATION) on PIPES, TANKS

TERMITES
TEST KITS for DUST, MOLD, PARTICLE TESTS
Thermal Expansion Cracking of Brick
THERMAL EXPANSION of HOT WATER
THERMAL EXPANSION of MATERIALS
THERMAL IMAGING, THERMOGRAPHY
THERMAL IMAGING MOLD SCANS
THERMAL MASS in BUILDINGS
TIMBER FRAMING, ROT
TIMBER ASSESSMENT
TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in BUILDINGS
VINYL CHLORIDE HEALTH INFO
VINYL SIDING
VINYL Siding or PLASTIC Window ODORS
Volatile Organic Compounds VOCs

WALL CONSTRUCTION BARRIER vs CAVITY
WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in BUILDINGS
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
WIND WASHING INSULATION At EAVES
WINDOWS & DOORS, Age, Types
WINTERIZE A BUILDING
WOOD FOUNDATIONS

More Information

Deck joist hanger and nails (C) Daniel FriedmanChoosing Structural Bolts: Through Bolts vs Lag Bolts
Deck Structural Connector Brackets & Plates
     

  • CONNECTORS, FASTENERS, TIES - Guide to choosing & installing Deck & Porch Construction & Structural Joist Hangers, Brackets, & Connectors
    • Deck & Porch Post & Beam Connectors: steel post cap connectors, plywood post to beam cleats, other connectors
  • DECK & PORCH CONSTRUCTION - home
  • DECK CONSTRUCTION BEST PRACTICES - separate article
  • DECK DESIGN & BUILD - article series home
  • FRAMING CONNECTORS & JOIST HANGERS - separate article
  • FRAMING FASTENERS, NAILS, SCREWS - separate article
  • Questions & answers aboutwhat types of joist & beam hangers & connectors are required for deck construction: joist hangers, connectors, steel tie plates, etc.
  • References

Click to Show or Hide Related Topics

  • STRUCTURAL INSPECTIONS & DEFECTS - home
  • COLUMNS & POSTS, DEFECTS
  • CONNECTORS, FASTENERS, TIES
  • DECK & PORCH CONSTRUCTION - home
  • DECK CONSTRUCTION BEST PRACTICES
    • BARK SIDE UP on DECKS & STEPS
    • DECK BEAMS & GIRDERS
    • DECK LEDGER BOARDS
    • DECK PIERS & POSTS
    • DECK FRAMING TABLES, SPANS
    • DECK FLASHING
    • DECK FLOOR & STEP CUPPING
    • DECK BOARD GAPS & SPACING
    • DECK & PORCH PRODUCTS
    • ROOFTOP DECK CONSTRUCTION
    • SYNTHETIC & COMPOSITE DECK BOARDS
  • DECK COLLAPSE Case Study
  • DECK FINISHES COATINGS PRESERVATIVES
  • DECK FLASHING LEAKS, ROT Case Study
  • DEFINITIONS of ENGINEERED WOOD OSB LVL etc
  • ENGINEERED WOOD Products
  • FRAMING CONNECTORS & JOIST HANGERS
  • FRAMING DAMAGE, INSPECTION, REPAIR
  • FRAMING FASTENERS, NAILS, SCREWS
  • FRAMING MATERIALS, Age, Types
  • FRAMING METHODS, Age, Types
  • FRAMING SIZE & Spacing, Age, Types
  • FRAMING TABLES, SPANS
  • FRAMING TRIANGLES & CALCULATIONS
  • FINISHES, COATINGS, STAINS
  • GLUES ADHESIVES, EXTERIOR CONSTRUCTION
  • INSECT INFESTATION / DAMAGE
  • KIT HOMES, Aladdin, Sears, Wards, Others
  • MODULAR HOME CONSTRUCTION
  • PANELIZED CONSTRUCTION
  • PORCH CONSTRUCTION & SCREENING
  • PRESERVATIVE TREATED LUMBER
  • RAILINGS, DECK & PORCH
  • RAILINGS, STAIRWAY
  • RETAINING WALL DESIGNS, TYPES, DAMAGE
  • RETAINING WALL GUARD RAILINGS
  • ROT-RESISTANT Deck Lumber & Flooring
  • STAIR RISE & RUN CALCULATIONS
  • STAIRS, DECK & PORCH CONSTRUCTION
  • STAIRS, EXTERIOR
  • STRUCTURAL DAMAGE PROBING
  • TRUSSES, Floor & Roof
  • WOOD STRUCTURE ASSESSMENT
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Structural connectors, fasteners, bolts, nails, joist hangers, rafter ties etc.: this article explains the proper selection and installation of structural connectors, brackets & tie plates used to connect deck or porch framing and support members. USP connectors such as joist hangers, joist angles, joist supports, stud shoes, skew hangers, and face mount hangers used for connecting these hangers and connectors are described, their uses explained, and their applications and specifications linked. Both galvanized steel and stainless steel joist hangers, connectors, & brackets may be applied.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

How to Choose the Correct Bolts or Fasteners for Structural Framing Connections in Wood Frame Construction, Decks & Porches

Simpson steel framing connectors (C) 2013 Daniel FriedmanThis article includes excerpts or adaptations from Best Practices Guide to Residential Construction, by Steven Bliss, courtesy of Wiley & Sons. Also see our review of that book. Our page top photo shows a hybrid deck structure that encompasses a boat. No fasteners were found securing the boat to the deck however.

Details about choosing the right structural connectors for decks and how they should be installed are at Fasteners/Connectors, Ties, Structural. At Fasteners, Nails, Screws, Hidden, for Decks we discuss choosing the proper nail, screw, or hidden fastener for fastening deck boards, railings, or joist hangers. Spans, sizes and spacings for deck joists and deck beams are discussed in detail at FRAMING TABLES, SPANS for DECKS and are shown in Table 4-7 and Table 4-8. Basic building framing information is found at FRAMING SIZE & Spacing, Age, Types.

Also see Deck Framing Tables, Spans and Deck & Porch Connections: Ledger Boards. And see Preservative-Treated Framing Lumber. see Rot-Resistant Deck Lumber & Flooring for a discussion of lumber and flooring alternatives to preservative-treated wood.

At minimum, all structural hardware for decks should be hot-dipped galvanized steel. For the best protection, use stainless steel (see “Joist Hangers and Connectors,” below). At connections carrying structural loads, such as deck ledgers or railing posts, use through-bolts or lag screws.

Through-bolts are stronger and should be used where possible. For the heaviest connections on a deck, such as where ledgers attach to the house or to posts, use 1/2-inch bolts or lags.

Place large washers under the heads of lags and at both ends of through-bolts. Re tighten bolts and lags after the first year and check periodically for tightness.

Machine-Threaded Bolts Used for Deck Construction

Framing nails to excess (C) Daniel FriedmanWhere both sides of the joint are accessible, bolts offer the strongest connections. Drill pilot holes 1/32 to 1/16 inch larger than the diameter of the bolt so it will slide through easily.

After drilling, saturate the hole with preservative. Use large washers under both the head and nut. Re tighten after the first year, since the wood may have shrunk.

Lag Bolts Used for Deck Construction

For lag bolted deck connections, drill a full-diameter pilot hole for the unthreaded portion and a smaller hole (65 to 75% of the lag’s diameter) for the threaded portion. So, for example, a 1/2-inch lag would get a 5/16-inch pilot hole for the threaded portion; a 3/8-inch diameter lag would get a 1/4-inch diameter pilot hole.

After drilling, saturate the pilot hole with wood preservative. It is also important that at least half the length of the lag is threaded into solid wood.

For example, driving a 5-inch lag through a 4x4 post into a 2x joist will produce a weak connection with only 1 1/2 inches of anchoring. Instead, the lag screw should go through the 2x and be threaded into the thicker 4x4. Use a large washer under the head, and re tighten after the first year in case materials have shrunk.

Joist Hangers and Steel Connectors Used for Deck Construction

At a minimum, use hot-dipped galvanized hardware. With pressuretreated wood, hot-dipped galvanized steel should conform to ASTM A153 (for fasteners) or ASTM A653, G185 (for connectors).

Stainless steel offers the best protection. Type 304 or higher stainless steel is recommended for very wet environments such as poolside decks; or Type 326 for exposure to salt or saltwater.

Watch out: Also, do not mix metals: Use stainless-steel fasteners with stainless-steel connectors and galvanized fasteners with galvanized connectors. And at Fasteners, Nails, Screws, Hidden, for Decks we include examples of fasteners that should not be used in joist hangers, such as drywall screws and other non-structural screws. or roofing nails.

Also see Deck Nails, Screws, Hidden Fasteners and see New Preservatives and Corrosion where we describe structural fasteners designed for use in pressure-treated lumber.

Suppliers of Joist, Post & Beam Hangers & Connectors & the Nails or Fasteners used With Them

Post to beam connections (C) J Wiley, Steven BlissStainless steel or galvanized steel joist hangers, connectors and similar products are produced by Simpson Strong Tie, Incom, Schuler Manufacturing, State Metals, Daytona Bolt & Nut, Hutchinson, Cleveland Steel, U.S. Lumber, Hohmann & Barnard, and Direct Tools & Fasteners as well as Paslode, Grip Rite joist hanger nails and other specialty nails.

  • Cleveland Steel Structural Fasteners, 26001 Richmond Rd., Bedford Heights, OH 44146,| Phone: 216.464.9400, Fax: 216.464.9404, E-mail: info@clevelandsteel.com, Website: http://clevelandsteel.thomasnet.com/category/construction-hardware-division?
  • Daytona Bolt & Nut, 815 N. Beach Street, P.O. Box 1391, Daytona, FL 32114, P: 386-255-0248, F: 386-257-5985, E-mail:Daytona@DaytonaBolt.com
  • Schuler Mfg. & Equip. Co. Inc., 63724 Richland Road, Griswold, Iowa 51535, Tel: (712) 774-2228 Website: http://www.schulermfg.net/
  • Simpson Strong Tie®, Tel:1-800-999-5099, Website: http://www.strongtie.com/
  • Incom Distributor Supply, PO Box 868, Fort Wayne IN 46801, Tel: 260-748, 5469, Website: http://shop.incomsupply.com/shop/, "... a growing nationwide network of over 500 Commercial Industrial Distributors" Incom Inc, 73-5600 Kauhola St Ste C, Kailua Kona, HI 96740, Tel: (808) 329-1311
  • USP Structural Connectors®, Tel: 1-800-328-5934, Email: uspcustomerservice@mii.com, Website: http://www.uspconnectors.com/

-- Adapted with permission from Best Practices Guide to Residential Construction.

Also see DECK COLLAPSE Case Study (collapse of a new code-approved deck) and DECK FLASHING LEAKS, ROT Case Study for an example of an older deck with rot and collapse due to improper construction and missing building flashing.


Frequently Asked Questions (FAQs) about framing connectiors, fasteners, joist hangers, rafter ties

...

Ask a Question or Search InspectApedia

Questions & answers or comments about what types of joist & beam hangers & connectors are required for deck construction: joist hangers, connectors, steel tie plates, etc. .

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Steve Bliss's Building Advisor at buildingadvisor.com helps homeowners & contractors plan & complete successful building & remodeling projects: buying land, site work, building design, cost estimating, materials & components, & project management through complete construction. Email: info@buildingadvisor.com
    Steven Bliss served as editorial director and co-publisher of The Journal of Light Construction for 16 years and previously as building technology editor for Progressive Builder and Solar Age magazines. He worked in the building trades as a carpenter and design/build contractor for more than ten years and holds a masters degree from the Harvard Graduate School of Education. Excerpts from his recent book, Best Practices Guide to Residential Construction, Wiley (November 18, 2005) ISBN-10: 0471648361, ISBN-13: 978-0471648369, appear throughout this website, with permission and courtesy of Wiley & Sons. Best Practices Guide is available from the publisher, J. Wiley & Sons, and also at Amazon.com
  • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  • Manual for the Inspection of Residential Wood Decks and Balconies, by Cheryl Anderson, Frank Woeste (Forest Products Society), & Joseph Loferski, October 2003, ISBN-13: 978-1892529343, $39.00 at Amazon.com or at the InspectAPediaBookstore
  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.

  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
  • GO TO Carson Dunlop's Home Study Course Information - How to Become a Home Inspector: Carson Dunlop's nationally recognized Home Study Course, selected by ASHI the American Society of Home Inspectors and other professionals and associations. This website author is a contributor to this course.
    Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd

  • ...

HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com