InspectAPedia®   -   Search InspectApedia

Deep well pumping capacity - Water Ace Co. Well Pump Capacitiy FAQs-2

Q&A on J et pump & Submersible pump GPM / LPM

Water well pump capacity questions & answers:

Frequently-asked questions and answers about the flow rate, pressure, or pumping capacity of water pumps or well pumps.

This article series compares the pumping capacity in gallons per minute of one line jet pumps, two line jet pumps, submersible pumps, and well pumps of different models and horsepower.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

Well Pump Capacity Questions & Answers

Deep well pumping capacity - Water Ace Co.Recently-asked Questions & Answers about Well & Water Pump Capacity Requirements

These questions and replies were posted originally

at WATER PUMP CAPACITIES TYPES RATES GPM - be sure to review the pump capacity details given there.

[Click to enlarge any image or table]

On 2018-11-01 by (mod) - friction losses in horizontal water piping

Shiddeshar,

The horizontal distance and pipe diameter should not significantly affect the pump requirements unless the friction and other losses (such as from many elbows or bends in piping) are unusually great

Or if the pipe diameter is quite small.

Beyond that point,

It's not just the pump horsepower that is important to get water lifted 60 feet from a water source.

It is also the type of pump.

A one-line or single-line jet pump can only lift water about 7.5 meters or 25 feet.

A two line jet pump of the same horsepower will have no trouble lifting water 60 feet.

Finally, the larger pump will deliver a faster water flow rate in liters per minute, but

watch out: if the pump rate out of the well exceeds the well's water in-flow rate then you'll pump the well dry.

On 2018-11-01 by Shiddeshar horure - my farm pipeline is 90mm lenth is 1700

Sir my question is

in my farm pipeline is 90mm lenth is 1700 feet and height is (from starting point to end point)50to 60 feet pumpset is 7hp then for which pumpset i buy for beter flow of water for agri in river and which type of valve i use for no comes pressure on pipeline i am a farmer and total land is 10 hector in this place

On 2018-08-07 15:14:18.930711 by Ali Reza

If 5hp motor
What is the Pump size?

On 2018-04-13 15:57:18.982379 by (mod) -

AM

I would start by reviewing what local well drillers have found in water tables in the area you're going to drill.

The pump capacity is not enough information. Critical is the ability of the well to deliver water - at what rate, over what period of time. For example if your well flow rate is rather weak, your pump may need to run for longer periods but with controls that limit its withdrawal rate so as not to exhaust the well.

Take a look at the ARTICLE INDEX give just above and you'll see a series of articles about well flow rates as well as pump capacity.

On 2018-04-13 09:40:35.540369 by Am johnson

I have a pending contract of drilling a 200 miter borehole(600 feet) in a community with a capacity of 5000 gallon water tank powered by a solar system. How do I go about it.I calculated a 3 horse power pump will work efficiently for about 9 hours to fill up the 5000 gallons and the solar systems with 5kva capacity will not last that long... I need a professional advice.

On 2018-03-06 21:24:47.666619 by (mod) -

There is no minimum usable depth for such a well - rather the question would be its flow rate. If the well cannot deliver 250 gpm - assuming you need that enormous water flow rate (that's 50 x the minimum usable residential flow rate) - you'd need an enormous water storage facility as well.

On 2018-03-06 20:56:20.982161 by Michele

What is the minimum depth of a well for a submersible pump capable of 250 gpm at 100 psi ?

On 2017-12-19 18:04:30.573885 by (mod) - Your total lift height is 150 ft.

Bob,

Indeed all well pumps are supported by a table showing their pumping capacity in gpm at various lift heights.

Your total lift height is 150 ft. Take a look at the data for your pump and compare that to what you think it's delivering. If the pump's actual output is in line with the table for 150 ft that will help us rule out a problem like a piping leak, low voltage, clogged inlet, damaged impeller.

You'd need to change to a higher capacity pump or you could perhaps add an intermediate pressure tank and booster pump at ground level.

On 2017-12-19 17:26:20.646512 by Bob Moyer

We have a 3/4 hp submersible well pump connected to a 1 1/4 pvc pipe 120 feet deep. This needs to pump water into a tank 30 feet in the air. It flows 10gmp where the plumbing comes out of the well. I don't feel the tank is filling fast enough because of all the lift. What do weneed to do to get more gpm in the tank.

On 2017-08-05 19:21:53.829364 by Jory

Hi, right now I have a 3hp booster pump that keeps blowing up on me I have roughly 150 feet of head on my propertyand I suck out of the creek. the silts and stuff are wearing out my impellers and I would like to do some thing different. I need a pump that will overcome that head and put out at least 30-35gpm at that height what kind of pump can I use?

On 2017-07-06 13:37:07.312198 by (mod) -

Balmain,

I can only give a part answer, as you don't specify a required water flow rate.

The lift height you cite is very little. So most pumps would be ok. See the Ace water pump cap acity chart in the article above. Even a 1/2 is ok.

Watch out that your pumping rate doesn't exceed 4th he well flow rate

On 2017-07-06 08:49:23.381084 by KALAIMANI ST

I HAVE WELL OF TOTAL 30 FEET DEEP, OUT OF IT WATER LEVEL FROM GROUND or PUMP SUCTION IS 16 FEET
WATER BED LEVEL 14 FEET.
WHAT IS RATWED CAPASITY PUMP I NEED TO FIX.

On 2017-07-05 19:59:08.487647 by (mod) -

Said:

A 1 hp submersible pump can typically pump 4 to 40 gpm - depending on several variables - see the table at the end of the article above.

Jeff:

Click to enlarge the "Submersible Pump" table in the article above to see an easier-to-read version
https://inspectapedia.com/water/Submersible_Well_Pump_Capacity.jpg

There you'll see that a 1/2 hp pump at 125 ft. is able to deliver about 7 gpm and is at the upper limit of its capacity.

On 2017-07-05 15:34:45.810201 by

1hp underground pump rate

On 2017-06-14 19:25:46.513591 by Jeff

i have a 130' deep 6" well, is a 1/2 HP 7gpm 230v pump ok

On 2017-04-12 14:04:19.368602 by (mod) -

Not if it's a one line jet pump design.
Yes if it's a 2 line jet pump properly installed or a submersible pump in the well.

For other readers, F&W pumps or Flint and Walling Pumps are a Zoeller company distributing water pumps and other equipment.
Contact

On 2017-04-11 00:21:57.130470 by Anonymous

Will an f & w half horse water pump pull 56 feet of water?

On 2017-03-24 00:20:42.437846 by Johnny

How many gpm a 1 1/2 hp pump pumps sprinkler pump

On 2017-03-23 03:05:12.762302 by (mod) -

You can use either a two-line jet pump or you can use a submersible pump. Part of the choice depends on where you want to locate the pump.

For example the submersible pump would be easy to install but requires that you put it in the downhill water source. Conversely a two-line jet pump could be installed at the uphill location.

On 2017-03-23 01:40:43.722416 by wilfred basquial

what type of water pump do I need to raise water uphill approximately 40 meters high

On 2017-02-01 18:04:19.443208 by (mod) -

MFA
It's not the pump that generates air in a water system, it's air leaks or improper air volume controls. Your air volume control will, however, need to be capable of handling the GPM and volumes and pump cycles involved.

On 2017-02-01 07:04:28.315364 by MFA

Hi, I have a 20mgd pump and a surge vessel to counter the hammering effect of backflows upon stopping the pump. My question is, will a 20mgd pump generate more air than 10mgd pump?

Reader Question on head total

(Apr 9, 2014) Awais Qadir said:

I have a centrifugal pump with under mentioned data

Flow = 135 us. gpm, Dynamic Head = 75 ft., Pipe I.D = 6 Inch, Delivery Length = 18000 ft., Bends 4 Nos.

What would be total head. Please mention with any example.

Reply:

Awais

Calculation of total head and dynamic head or TDH is detailed in the article WATER PUMP CAPACITIES TYPES RATES GPM.

On 2017-02-01 18:04:19.443208 by (mod) -

MFA
It's not the pump that generates air in a water system, it's air leaks or improper air volume controls. Your air volume control will, however, need to be capable of handling the GPM and volumes and pump cycles involved.

On 2017-02-01 07:04:28.315364 by MFA

Hi, I have a 20mgd pump and a surge vessel to counter the hammering effect of backflows upon stopping the pump. My question is, will a 20mgd pump generate more air than 10mgd pump?

On 2016-12-05 16:52:53.504138 by Gar

I have a spring located approximately 350 ft below in elevation from my holding tank and approximately 1800 linear feet from this holding tank. How do I calculate the horsepower and flow rate that I need for a pump?

On 2016-10-25 by (mod) - diagnose poor water pressure - it may not be the pump

Dianne,

Changing to a slightly more powerful pump won't itself explain having no water, though I include a caveat just blow addressed to Anon.

Please see WATER PRESSURE LOSS DIAGNOSIS & REPAIR where we give diagnostic and repair steps for the problem you describe: no water pressure at all. Let me know by comment or email (page bottom CONTACT link) how you make-out and don't hesitate to ask if the information to which I refer you is unclear or seems incomplete.

On 2016-10-25 by Dianne

I had a 3/hp sub well pump. I was given a 1/2 hp sub pump. I changed the Control box an still no water..Help Plzzz.

On 2016-10-24 by (mod) - I would like to change it to a 1 and 1/2 pump. would that hurt anything?

Anon:

Basically, no that's fine.

But there can be a subtle issue: if the new pump delivers water out of the well at a faster flow rate in GPM then IF the well flow rate is marginal or very modest, the newer, more powerful pump can cause the well to run out of water.

That can be managed by adding flow rate controls on the water system.

On 2016-10-24 by Anonymous

There was a 1 horsepower submirsable pump in a drilled well that burnt out. I would like to change it to a 1and 1/2 pump. wold that hurt anything?

On 2016-10-12 22:30:38.256628 by ron

sorry I meant a 25 ft height difference between the house level ( highest fixture ) & the pump ? It's appx. 200 ft. from the house to well in distance. Currently using a 3/4 hp pump 1.25 inlet & 1" outlet.

On 2016-10-12 22:26:25.791699 by ron

I have a shallow well pump rated at 25 ft. lift - is that the same as me using it to pump water 25ft uphill to my house ?

On 2016-09-07 03:03:38.210849 by vikram mody

I would like to develop a 5 H.P. open well centrifugal pump. From where I can get design data for the same like impeller diameter, inlet blade angle, outlet blade angle etc.

On 2016-08-25 15:10:39.950636 by J PRASAD

Open canal system how much 7.5 HP pump delivery discharge in cuces

...


...

Continue reading at WATER PUMP CAPACITIES TYPES RATES GPM or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Water Pump Articles

Suggested citation for this web page

WATER PUMP CAPACITY & GPM FAQs-2 at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.


Comment Form is loading comments...

 

IF above you see "Comment Form is loading comments..." then COMMENT BOX - countable.ca / bawkbox.com IS NOT WORKING.

In any case you are welcome to send an email directly to us at InspectApedia.com at editor@inspectApedia.com

We'll reply to you directly. Please help us help you by noting, in your email, the URL of the InspectApedia page where you wanted to comment.

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT