Septic system contaminants FAQs
Septic system contaminants & pathogens FAQs:
This article answers frequently-asked questions about contaminants found in onsite septic systems.
The photo above shows what dirt and sewage effluent may look like in a yard where the sewer line between the house and septic tank
is damaged and leaking.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
ADVERTISEMENT
Q&A on Septic Tank & Onsite Septic System Contaminants & Pathogens
Watch out: sewage spills contain contaminants that can cause serious illness or disease. Disease causing agents in raw sewage include bacteria, fungi, parasites, and viruses and can cause serious illnesses including bacterial infections, Tetanus, Hepatitis A, Leptospirosis, infections by Cryptosporidium & Giardia and gastrointestinal diseases.
Church triee bleach down drains to treat a sewage backup
Our church has two busted sewage pipes for 6 months to a year. It has never been addressed. Prior to the start of weekly church service, the smell is so bad until the deacons pour bleach and ammonia down the toilets.
People are starting to be sick with bad coughs and breathing issues with headaches.
Some have recently experienced heavy complaints of nausea from myself. Is this something the health department can help with or should the church close for a few day and allow the city to come in and fix the pipe. Also the offices in the church have somehow received water damage and the the ceilings and panel falling down and will not stay up.
by (mod) - that won't work
Angel
Unfortunately, trying to treat the smell of a sewage backup is not a step that will prevent possible health hazards. Worse, if sewage has actually flooded the interior those areas need to be cleaned and disinfected. If sewage entered ceiling, floor, or wall cavities those walls need to be opened and cleaned.
The drains need to be repaired and the building properly cleaned and restored for safety and health.
Your health department may be able to give better advice on-site, as might a company who has experience and expertise in cleaning up sewage backups in buildings.
This website also provides a series of articles on sewage backup cleaning procedures and standards starting at
SEWAGE CONTAMINATION in BUILDINGS
What pathogens may enter a house through its plumbing system?
Are airborne pathogens dangerous entering house through plumbing
Terry:
The question is a bit broad but in general, improperly-installed plumbing drains can permit methane and sewer gas and potentially other harmful particles, bacteria, viruses into a building;
Plumbing drains can also harbor harmful fungal growth, though again only if drains back up or are improperly vented would there be likely passage of those pathogens into building air. I'll cite some pertinent research below.
Plumbing supply piping would not normally bring pathogens or harmful materials into a building unless the water supply itself were already contaminated in which case of course there could be aerosolized or airborne bacteria, viruses as well as potentially harmful gases including radon IF radon is in the local water supply.
Exceptions that could enter a building in the supply piping system (besides direct water supply contaminants of any sort) include be bacterial growth in a water heater (geyser, calorifier, cylinder) or lead or other contaminants in water supply piping.
Research on pathogens entering building through plumbing supply or drain systems
- Dwidjosiswojo, Zenyta, Jessica Richard, Miriam M. Moritz, Elke Dopp, Hans-Curt Flemming, and Jost Wingender. "Influence of copper ions on the viability and cytotoxicity of Pseudomonas aeruginosa under conditions relevant to drinking water environments." International journal of hygiene and environmental health 214, no. 6 (2011): 485-492.
- Gormley, Michael, J. A. Swaffield, P. A. Sleigh, and C. J. Noakes. "An assessment of, and response to, potential cross-contamination routes due to defective appliance water trap seals in building drainage systems." Building Services Engineering Research and Technology 33, no. 2 (2012): 203-222.
- Gormley, Michael, Thomas J. Aspray, David A. Kelly, and Cristina Rodriguez-Gil. "Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig." PloS one 12, no. 2 (2017): e0171556.
- Hilborn, Elizabeth D., Terry C. Covert, Mitchell A. Yakrus, Stephanie I. Harris, Sandra F. Donnelly, Eugene W. Rice, Sean Toney, Stephanie A. Bailey, and Gerard N. Stelma. "Persistence of nontuberculous mycobacteria in a drinking water system after addition of filtration treatment." Applied and environmental microbiology 72, no. 9 (2006): 5864-5869.
- Howard, Guy. "Arsenic, drinking-water and health risk substitution in arsenic mitigation: a discussion paper." World Health Organization, Geneva (2003).
- Sanchez, Jose L. "Investigation of a cluster of Legionella pneumophila infections among staff at a federal research facility." Military medicine 166, no. 9 (2001): 753.
- Short, Dylan PG, Kerry O'Donnell, Ning Zhang, Jean H. Juba, and David M. Geiser. "Widespread occurrence of diverse human pathogenic types of the fungus Fusarium detected in plumbing drains." Journal of clinical microbiology 49, no. 12 (2011): 4264-4272.
Harvard
- Falkinham, Joseph O., Amy Pruden, and Marc Edwards. "Opportunistic premise plumbing pathogens: Increasingly important pathogens in drinking water." Pathogens 4, no. 2 (2015): 373-386.
- Falkinham III, Joseph O., Elizabeth D. Hilborn, Matthew J. Arduino, Amy Pruden, and Marc A. Edwards. "Epidemiology and ecology of opportunistic premise plumbing pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa." Environmental Health Perspectives (Online) 123, no. 8 (2015): 749.
- Williams, Krista Ann. "Relationship Between Organic Carbon and Opportunistic Pathogens in Simulated Premise Plumbing Systems." PhD diss., Virginia Polytechnic Institute and State University, 2011.
- Zuthi, M. F. R., M. Biswas, and M. N. Bahar. "Assessment of supply water quality in the Chittagong city of Bangladesh." ARPN Journal of Engineering and Applied Sciences 4, no. 3 (2009): 73-80.
I contacted strongyloides after leaks in the broken orangeburg tile from the street to the house we rented
I contacted strongyloides after leaks in the broken orangeburg tile from the street to the house we rented
--I had 2 yrs of illness and then the city fixed the street of many houses in the complex and told the landlords their tile was crushed and had been for some time and now I am very sick from the backup and 2 yrs exposure to parasites and mold
--we moved and now we have the parasites here in the new home
--what can we do to save the people from our problem --we can see the strongyloides on the surface of sinks and clothes and papers
--and my body --I am going to emery to see if I can get rid of them but I am having bad site bad hearing bad dizziness and fat tummy but lost weight ==
its a long fight and we want to live in a clean house with what we have salvaged which probably is full of parasites now
---we left so much in the home I don't evn know what the landlord did with it
---I hope not give it away ---they sold the house for two times its worth and I know they have not fixed the tile to the house yet ---
Sewage on the basement floor of my rental home
I'm currently renting & there is sludge on basement floor,I have spoke to two prior tenants and it was there when they were living here,There is a terrible smell that goes through the house when heat or central air is running. It smells like sewer,rotten trash dump,sulphur like matches.
I got sick,couldn't walk,vomiting,seizurs,went to e.r. had infection in my intestines & sepsis. Also my son has been having breathing problems,took him to doctor & had tests done,he was diagnosed with asthma. One tennant had sepsis but she had moved & it was a week after moving from here.
Other tennants,child got e.coli & other child,asthma. We all have had simalar things,headaches,sinus infections,earinfections,uncordination problems,slew of medical problems. Toilet backs up,kitchen drain backs up. And the landlord knows,has had 3 tennants tell him.
There is no inspection ordinace in this town. But im thinkin of contacting county health department. I've been here a year & was ready to move after 2 months. I'm looking for another place! I will not drink the tap water! -
Explanation by (mod) -
Your description sounds as if the home was previously flooded or perhaps suffered a sewage backup. \
The smell you describe, if it is sewer gas, is potentially explosive.
If there was a flood of sewer backup that was not properly cleaned there are quite likely to be health hazards in the building and in its HVAC systems.
If the owner has not responded to a combination of prompt oral and written notice of your concerns you may need to ask for help from your local health department.
For a detailed list of the pathogens found in common household wastewater such as a septic tank and drainfield, see also our discussion of pathogens in sewage
at SEWAGE PATHOGENS in SEPTIC SLUDGE: what makes up the contents of residential sewage? Stated more simply, and according to various sources such as
the Utah DEQ
Search InspectApedia.com for
Tenant Help With Landlord
to read more specific suggestions
See also ORANGEBURG PIPE
...
Continue reading at SEWAGE & SEPTIC CONTAMINANTS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
Suggested citation for this web page
SEWAGE & SEPTIC CONTAMINANT FAQs at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Share this article:
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
Citations & References
In addition to any citations in the article above, a full list is available on request.
- New York State Department of Health, APPENDIX 75-A WASTEWATER TREATMENT STANDARDS - INDIVIDUAL HOUSEHOLD SYSTEMS , [PDF] New York State Department of Health, 3 February 2010, retrieved 3/1/2010, original source: https://www.health.ny.gov/regulations/nycrr/title_10/part_75/appendix_75-a.htm
- Warish Ahmed, Marek Kirs, and Brent Gilpin, "Chapter 21: [Sewage Fecal Contaminant] Source Tracking in Australia and New Zealand: Case Studies", C. Hagedorn et al. (eds.), Microbial Source Tracking: Methods, Applications, 485
and Case Studies, DOI 10.1007/978-1-4419-9386-1_21,
© Springer Science+Business Media, LLC 2011
- "Bacterial Pathogens Recovered from Vegetables Irrigated by Wastewater in Morocco", Y. Karamoko, K. Ibenyassine, M. M. Ennaji, B. Anajjar, R. Ait Mhand, M. Chouibani, Journal of Environmental Health, June 2007.
Abstract:
The authors obtained 50 vegetable samples from various regions in Morocco and examined them to determine the micro biological quality of these products. Aerobic count, coliform, enterococci, and Staphylococcus areus were evaluated. This analysis revealed high levels of enterococci, fecal coliforms, and total coliforms. No coagulase-positive Staphylococcus aureas was detected in any of the samples analyzed. Biochemical identification of Enterobacteriaceae showed the presence of Citrobacter freundii (28 percent), Enterobacter cloacae (27 percent), Escherichia coli (16 percent), Enterobacter sakazakii (12 percent), Klebsiella pneamoniae (17 percent), Serratia liquefaciens (11 percent), and Salmonella arizonae (0.7 percent).
The results clearly demonstrate that vegetables irrigated with untreated wastewater have a high level of microbiological contamination. Consequently, these vegetables may be a threat for the Moroccan consumer and may be considered a serious risk to Moroccan public health.ABSTRACT FROM AUTHOR Copyright of Journal of Environmental Health is the property of National Environmental Health Association and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use.
This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.
CONTACT US to request a copy of this article stored as BacterialPathogens.pdf if you have difficulty obtaining a copy of this full article for private use.
- Beuchat, L.R. (1996). Pathogenic microorganisms associated with
fresh produce. Journal of Food Protection, 59(2), 204-216.
- Breuer, T, Benkel, D.H., Shapiro, R.L., Hall. W.N., Winnett. M.M.,
Linn, M.J., Timothy, J.N., Barrett. J., Dietrich, S., Downes, EP,
Toney, D-M., Pearson, J.L., Rolka. H., Slutsker. L, & Griffin, PM.
(2001). A multi-state outbreak of Escherichia coli O157:H7 infections
linked to alfalfa sprouts grown from contaminated seeds,
Emerging Infectious Diseases, 7(6), 977-982.
- Evans, M.R., Ribiero, CD., & Salmon, R.L. (2003). Hazards of
healthy Living: Boiled water and salad vegetables as risk Factors
For Campylobacter infection. Emerging Infectious Disease, 9(10),
1219-1225.
- Guo, X., Chen, j . , Brackett, R.E., & Beuchat. LR. (2001). Survival of Saimonellae on and in tomato plants From the time of inoculation at
flowering and early stages of fruit development through fruit ripening.
Applied and Environmental Microbiology, 67(10), 4760-4764
- Madden, J.M. (1992). Microbial pathogens in fresh produce—The
regulatory perspective. Journal of Food Protection, 55, 821-823.
- Shearer, A.E., Strapp, CM., & Joerger, R.D. (2001). Evaluation of
polymerase chain reaction-based system for detection of Salmonella
enteritidis, Escherichia coli O157:H7, Listeria spp., and Listeria monocytogenes on Fresh Fruit and vegetables. Journal of Food
Protection, 64(6), 788-795.
- "Septic Tank/Drainfield System Fact Sheet", [PDF] Utah Department of Environmental Quality, Division of Drinking Water, Source Protection Program - (801) 536-4200 Division of Water Quality - (801) 538-6146 Sonja Wallace, Pollution Prevention Coordinator - (801) 536-4477 Environmental Hotline - 1-800-458-0145 - Original source: http://www.drinkingwater.utah.gov/documents/spec_services/pollution_prevention_septic_tanks.pdf
- New York State Wastewater Treatment Standards - Individual Household Systems, Appendix 75-A (1990),
Public Health Law 201(1)(1).
- New York State Alternative Septic System Design Regulations, Wastewater Treatment Standards - Individual Household Systems, Appendix 75-A, of Public Health Law 201(1)(1) 1990.
- Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
- In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
CONTINUE READING or RECOMMENDED ARTICLES.
ADVERTISEMENT