Water Softener Resin Properties & Sources Resin bead sizes, uses, types, & where to buy softener resin
POST a QUESTION or COMMENT about this water softener resin types, replacement, properties & bead sizes or mesh sizes
This article describes water softener resin beads: the different resin types, bead sizes.
We include a list of manufacturers of and sources of water treatment resin beads or similar products along with the product specification data sheets for various resin products.
Just as the water softener resin bead size is generally given as a size range by the manufacturer; you can actually see from our lab photos shown on this page that the actual resin bead sizes vary within the manufacturer's specified range - they are not identical in diameter.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
Water Softener/Treatment Resin Properties & Sources
Sizes of Water Softener Resin Product Specifications & Resin Bead Sizes
The greater total resin bead surface area provided by fine-mesh water softener resin beads increases the softening capacity of a water softener by about 10 percent over regular mesh resins but the softener's filter that keeps the resin beads from leaving the softener must be sized appropriately as well.
Definition: Regular mesh water softener resin beads: bead size is between 16 mesh (1.2mm) and 50 mesh (0.3mm) and the water softener resin retaining filter or stack distributor will use slots in the .010-.013 mm range.
Definition: Fine mesh water softener beads: bead size is between 40 mesh (0.4 mm) to 50 mesh (0.30 mm) and the water softener filter or stack distributor will use slots in the .007-.010 mm range.
Water Softener Resin Product Data
Purolite PRODUCT GUIDE - CHARACTERISTICS & APPLICATIONS [PDF] Lenntech
info@lenntech.com
www.lenntech.com
Tel. +31-15-261.09.00 retrieved 2021/11/17 original source: https://www.lenntech.com/Data-sheets/Purolite-Product-Summary-Guide-L.pdf
Excerpt: Inside this Characteristics and Applications summary you will find a broad overview of
all Purolite Products.
PUROLITE C100E WATER SOFTENER PRODUCT DATA SHEET [PDF] (2021) Purolite Corporation
2201 Renaissance Blvd.
King of Prussia, PA 19406
T +1 800 343 1500
T +1 610 668 9090
F +1 800 260 1065
americas@purolite.com retrieved 2021/11/17 original source: https://www.purolite.com/product-pdf/C100E?MATCHTYPE=.pdf
Also find Purolite C100 EFM Cation Softener Resin, Fine Mesh
Excerpts: Used in some "mini" sized softeners, and some larger high iron applications ( usually requires a gravel underbedding and special fine mesh distributor ).
Only recommended for special applications.
We recommend using the ResinTech CG8, Sybron C249, or similar "standard" mesh High Capacity resins for residential water softener applications.
PUROLITE SSTC60 WATER SOFTENER RESIN PRODUCT DATA [PDF] (2018) Purolite, Op. Cit., https://www.purolite.com/dam/jcr:93bd98dd-de72-47a4-b678-3f31f03ae318/SST60%20Engineering%20Bulletin%20_2018FINAL.pdf
Excerpt: SSTC60 is a high-performance gel strong acid cation resin
for potable and non-potable softening applications
Purolite's largest SST water softener bead size is 0.187mm in diameter in the bead active core.
Purolite BASICS of ION ECHANGE [PDF] Purolite Corp., Op. Cit., https://www.purolite.com/index/Company/Resources/ion-exchange-resin-glossary/what-is-ion-exchange
Excerpt:
Ion exchange is a method for decontamination and purification of water and helps to remove unwanted compounds in water.
ResinTech, Resin Tech CG8 SOFTENER RESIN [PDF], ResinTech Inc, 1801 Federal Street Camden, NJ 08105 USA Tel: 856.768.9600 email info@resintech.com web resintech.com, 16 to 50 US Mesh (297 - 1190 μm) Excerpts:
Strong Acid Cation Resin, Polystyrenic Gel Crosslinked with 8% Divinylbenzene, Sodium Form
CG8 has good capacity for ferrous iron. Iron content in the
feedwater should not be more than 1 mg/L Fe per each 17
mg/L of hardness.
Sybron, Sybron IONAC C-249 WATER SOFTENER RESIN PRODUCT DATA [PDF] Sybron Chemicals Inc.
A LANXESS COMPANY
200 Birmingham Road
Birmingham, NJ 08011
Phone: 1-800-678-0020
Fax: 609-894-8641
www.sybronchemicals.com
Sybron is a Lanxess company. Resin bead size US Mesh 16-40.
The largest standard water softener resin bead size is 1.2mm in diameter
Purloite's UPS water softener bead size is 0.71mm in diameter
Sources of water softener tank resin to replace original material
...
Shown above: mixed bed ion exchange water softener or water treatment resin from CarboChem - cited just below.
Typical water softener resin is sold in bead-form, as a conventional gel polystyrene sulfonate cation exchange resin that is ready for use in household or industrial water conditioning equipment such as a water softener or water conditioner.
The resin should meet the specifications of your water softener manufacturer, and/or the U. S. Food and Drugs Code of the Federal Regulations section 21 paragraph 173.25.
Contact your water softener manufacturer, since as we note: there may be other parts that you also want to replace at the same time: the riser tube inside the treatment tank, O-rings, Seals, Gaskets and possibly check valves
APS Water: water softener resin beads, APS Water Services Co., 7320 Valjean Ave., Lake Balboa CA 91406, USA, Tel: U.S. 800-460-9011, Website: http://www.apswater.com/ Email: public@apswater.com
Carbochem Ion Exchange Resins, CARBOCHEM INC.
308 E. Lancaster Avenue
Wynnewood, PA 19096-2145
USA
Phone: (610) 645-9200
Fax: (610) 645-5501
E-mail: HQ@carbochem.com Web: https://carbochem.com/
DOW HCR-SS Water Softener Resin, DOWEX™ HCR-S/S cation exchange resin
General Technologies, SPC, Nelson Cation Resin [illustrated in 1 cubic foot bag, just above] Email: support@nelsencorp.com Tel:
(800) 362-9686 Web: https://www.nelsencorp.com/
Locations at Ohio - (800) 362-9686 3250 Barber Rd., Norton, OH 44203
Arizona - (866) 445-4299 14035 West El Cielo, Goodyear, AZ 85338
Texas - (855) 674-0357 1012 Assembly Circle - # 100, Schertz, TX 78154
Florida - (866) 712-6796 4410 E. Adamo Dr. Suite 102, Tampa, FL 33605
Excerpt: CATION Standard resin is a high capacity, conventional gel polystyrene strong acid cation exchange resin designed for use in residential or industrial water softening equipment. Cation resin in sodium form removes hardness ions such as calcium and magnesium by replacing them with sodium.
When the resin bed is exhausted the hardness ions begin to pass through the bed. Functionality is returned by regeneration with concentrated sodium or potassium chloride solution. The capacity obtained depends largely on the amount of salt used in the regeneration. Typically 15 lbs. of chemical per ft3 is used to obtain maximum capacity of up to 33,000 grains per ft3.
Our standard mesh cation exchange resin provides for economical softening capabilities of both household and commercial water softeners. WQA Gold Seal certified against NSF/ANSI 61.
PurOLite Ion Exchange Resins, Purolite Water Softener Resin, 8% Crosslink - this is the water softener resin product used in our illustrations above.
Purolite Corporation
2201 Renaissance Blvd.
King of Prussia, PA 19406
T +1 800 343 1500
T +1 610 668 9090
F +1 800 260 1065
americas@purolite.com
Purolite RESINS for POTABLE and GROUND WATER TREATMENT [PDF] Product Bulletin Lenntech
info@lenntech.com
www.lenntech.com
Tel. +31-15-261.09.00 retrieved 2021/11/17 original source: https://www.lenntech.com/Data-sheets/Potable-and-Ground-L-pdf.pdf
Important excerpt: While ion exchange resins can be used to selectively
remove specific contaminants, it is recognized that
membrane and other broad-based removal
technologies are suitable alternatives for reduction of
high total dissolved solids (TDS) in brackish water
supplies.
Membrane fouling from colloidal particulate
matter, TOC and scale forming compounds can limit
the percentage of permeate water that is recoverable.
Purolite’s membrane pretreatment resins can reduce
colloidal particulates, TOC and scaling potential, to
give a lower silt density index (SDI) and increase
membrane operating efficiency and recovery rates.
Res-Kem General Water, Aston, PA Location
2 New Road
Aston, PA 19014
USA, Phone: 800-323-1983, Website: http://www.reskem.com, Email: sales@reskem.com
Sears Water Softener Resin Cleaner, an iron-removing chemical treatment available from Sears and sold through Sears Distributors. Sears Item# 04234427000 | Model# 34427 Website: http://www.sears.com
Online sales stores such as Amazon
Diagnose & Fix Water Softener Problems: this article series describes procedures for diagnosing and repairing water softener or water conditioner problems including water conditioner control settings and adjustment or repair, brine tank and brine tank float cleaning and repair, and the proper amount of water softening or conditioning that is needed.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.