US Craftsmaster water heater age decoders, water heater manual sources.
The water heater age guide on this page works for a long list of water heater brands given below.
In this article series we give details of how to de-code water heater age for all water heater brand. We also discuss the conditions, maintenance, and factors that affect how long a water heater can be expected to last.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
U.S. Craftsmaster water heater age is usually encoded in the first four digits of the heater's serial number as in this example:
YYWW1234
[Click to enlarge any image]
Where WW is the week number (weeks 01 through 52) and of course YY indicates the last two digits of the year of manufacture.
U.S. Craftsmaster is an indpendent water heater manufacturer whose heaters have been sold under the following trade names or brand names
Ace Water Heaters, Ace Hardware Water Heaters, American Hardware Water Heaters, America's Best Water Heaters, Apex Water Heaters, Aqua Temp Water Heaters, Aqua Therm Water Heaters, Aquamatic Water Heaters,
Best Water Heaters, Best Deluxe Water Heaters, Craftmaster Water Heaters, De-Limer Water Heaters, Deluxe, Eagle Water Heaters, The Earl's Energy Conservation Water Heater, The Earl's Energy Saver Plus Water Heaters, Envirotemp Water Heaters,
Four Most Water Heaters, Hotmaster Water Heaters, Hotstream Water Heaters, King-Kleen Water Heaters, King-Line Water Heaters, Master Plumber Water Heaters, Nationaline Water Heaters, Neptune Water Heaters,
Penquin Water Heaters, Prestige Water Heaters, Pro-Line Water Heaters, Pro-Line Plus Water Heaters, Quaker Water Heaters, Quick-Flo Water Heaters, Raywall Water Heaters, Revere Water Heaters, Riviera Water Heaters,
Sands Water Heaters, Sentinal Water Heaters, Sentinel Water Heaters, Servistar Water Heaters, Shamrock Water Heaters, Special Deluxe Water Heaters, Standard Water Heaters, Supereagle Water Heaters, Super-Flo Water Heaters, Supreme Water Heaters, Sure-Fire Water Heaters,
Thoro-Clean Water Heaters, True-Test Water Heaters, Tru Value Water Heaters, Tru Value Hardware Water Heaters, U.S. Craftmaster Water Heaters, U.S. Supply Water Heaters, Whirlpool Water Heaters, XCL Energy Saver Water Heaters
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
On 2020-05-02 by mod) - U.S. Craftsmaster water heater age
Envirotemp ? No. This is a US/Craftsmaster water heater
US Craftsmater Water Heater
Serial No. 9728102084
The data tag gives year and week in the first four digits of the serial number
S/N 9728102804
Year 1997
Week 28
Contact: US/Craftsmaster Water Heater Co.,
1100 E. Fairview Ave
Johnson City TN USA
On 2020-05-01 by Cheryl Conley - U.S. Craftsmaster water heater data tag
What year is this water heater? [photo above]
On 2020-05-02 - by (mod) - What year is this water heater? [
Envirotemp
US Craftsmater Water Heater
Serial No. 9728102084
Probably
Year 1997
Week 28
On 2020-05-01 by Cheryl Conley
What year is this water heater? [photos shown at page top - Ed.]
This Q&A were posted originally at ENVIROTRON ENVIROTEMP WATER HEATER AGE
...
Continue reading at WATER HEATER LIFE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
US-CRAFTSMASTER WATER HEATERSInspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about how to find out the age of a heating appliance: water heater, heating boiler, heating furnace.
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.