Building Foundation Cracks & Structural Defects List & Home Inspection Education
This article lists significant Foundation Cracks & Structural Defects defects, definitions, and home inspection education topics.
This article series, beginning at BUILDING DEFECTS LISTS, provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website.
Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here.
1. Describe the function of footings and foundations.
2. Describe seven soil types and their relative strength or weaknesses with respect to carrying the building.
3. Describe these common configurations for house foundations: basements, crawl spaces, slab-on-grade.
4. Describe these common types of slab-on-grade construction: floating ? is this a mat slab?, supported by what? and monolithic slab also two-pour slabs
5. Describe these common footing types: spread, pad, piles, piers.
6. List four common footing materials (concrete, brick, stone, wood).
7. List seven foundation materials ( concrete, concrete block, cinder block, brick, hollow clay tile, stone, wood).
8. Describe the features of adequate installation and repair technique for each of the footing and foundation types described above.
9. Define the following terms with respect to footings and foundations:
live load, dead load, frost heaving, pilaster, pile, pier, caisson, grade beam, raft foundation, mat foundation, differential settling, honeycombing of concrete, cold joint in concrete, control joint, cut-and-fill lot, mud jacking, underpinning, foundation irrigation, step footing, bench footing, adfreezing, lateral thrust, hydrostatic pressure, lateral support, buttress, sister wall, helical anchor.
9. Identify the codes or standards which apply to foundations and footings in your area.
1. Describe the inspection procedure for foundations.
2. Identify the following common defects listed on the next page.
3. Describe the implication of each of these defects.
4. Communicate findings to client, verbally and in writing, recommending corrective action where needed.
• Basement lowered (suspect)
• Bowed, bulging or leaning
• Cold joints
• Cracks
• Crushed
• Foundations too short
• Foundations too thin
• Hollow masonry units installed on their sides
• Honeycombing
• Insect or fire damage
• Large trees close to building (suspect)
• Lateral support poor
• Lateral movement
• Mechanically damaged
• Mortar deteriorating or missing
• Not well secured
• Pilasters moving
• Prior repairs
• Rot or wood/soil contact
• Spalling, crumbling or broken material
• Steep slope or unstable soil
• No foundation, such as the patio slab that becomes a room
1. Describe the function of floor systems and structures.
2. Describe two common floor systems (wood, concrete).
3. List the materials and components of each floor type described above (for wood ? sills, columns, beams, joists, subfloor; for concrete ? concrete, reinforcing bar, forming, columns, beams).
4. Describe the features of adequate installation and repair technique for each type of flooring described above.
5. Define the following terms with respect to floor systems:
strength, stiffness, deflection, sill, column, beam, joist, subflooring, sill gasket, mud sill, anchor bolts, spalling, 1/3 rule for column stability, rising damp, glulam, laminated veneer lumber (LVL), parallel strand lumber (PSL), engineered wood, end bearing, continuous span beam, simple span beam, concentrated load, ribbon board, ledgerboard, joist hanger, fire-cut joist, rim joist, OSB, wood I TJI?(Wood I-joists) JDG cantilevers, bridging, blocking and strapping, mortise and tenon joint, waferboard, tongue and groove, prestressed concrete, post-tensioned concrete, floor trusses.
6. Identify the codes or standards which apply to floor systems in your area.
1. Outline the inspection procedure for wood and concrete floor systems.
2. Identify the following common defects listed on the next page.
3. Describe the implication of each defect.
4. Communicate findings to client verbally and in writing, recommending corrective action where needed.
Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website.
These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors.The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997.
Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.
...
Continue reading at ARTICLE INDEX to BUILDING DAMAGE, DISASTER, REPAIR or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
STRUCTURE, FOUNDATION DEFECTS LIST at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.