Gravelless septic drainfield site requirements:
This article explains the site requirements, design criteria, and construction details of a gravelless or "no gravel" or "no rock" septic drainfield systems, offering installation specifications.
Citation of this article by reference to this website and brief
quotation for the sole purpose of review are permitted. Use of this information at other websites,
in books or pamphlets for sale is reserved to the author. Technical review by industry experts has
been performed and comments from readers are welcomed. Contributors are listed at the end of each
article.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Site Requirements & Design Criteria for Gravelless Septic Absorption Systems
Drainfields, also called leach fields, absorption
beds, soil absorption systems, and leaching beds, perform the functions of septic effluent treatment and disposal
in onsite wastewater treatment systems, conventionally called "septic systems".
Typical gravelless septic systems use a plastic chamber,
a geotextile-wrapped pipe, or a polystyrene-wrapped pipe to distribute effluent into the soil.
The necessary soil absorption area is provided by the perforated surface of the gravelless septic system components (or by soil at the bottom of a chamber) themselves rather than by the gravel and
trench walls of a conventional septic drainfield.
Site Requirements for no-rock chamber or textile wrapped septic effluent disposal systems:
These systems shall be used on sites that have
been classified as having a design percolation rate of one to 45 minutes
per inch, and meet the vertical and horizontal separation distances in
Table 2 (of the New York State Standard - for example) shown in 75-A.4 Soil and site appraisal for Septic Systems.(2)
Chamber systems provided by Infiltrator Inc. (links below) have been approved for use in some states, including New York,
at perc rates up to 60 minutes/inch, and in some other states, at percs up to 120 minutes/inch. Approval letters are
available from that company.
Design criteria for no-rock chamber or textile wrapped septic effluent disposal systems: :
The local health department having jurisdiction shall be contacted prior to construction regarding the acceptability of
specific products for use as a gravelless distribution system. (3)
As we described above when discussing Geotextile-Wrapped Perforated Pipe systems for onsite wastewater treatment and
disposal, the total lot area in square feet which is required for a given alternative treatment system will vary not only
depending on the anticipated daily flow, flow rates, soil and site conditions, but also on what spacing requirements the local
or state code officials will require.
So although a number of alternative treatment systems including these gravelless
methods are capable of working in a smaller total square foot area than a conventional drain field, depending on what the
local authorities require in spacing, more area may be required than the minimum.
For example, many states require that
space be set aside to allow for future absorption line replacement in between the planned lines.
Construction Specifications for gravelless septic absorption systems
Gravelless distribution systems shall be installed in
conformance with the manufacturer's instructions because of the
proprietary design of some products.(4) The length, width, and depth of the
required excavation will vary by individual product.
The essential difference between
a gravelless wastewater treatment system and a conventional perforated-pipe and gravel-trench drainfield
is the use of a special product to distribute and release effluent (sketches above) and the absence of
gravel in the trench where the distribution system is buried.
The special gravelless products used
are designed to avoid soil-clogging right at their surface or they would have a short life.
This
concern is addressed by use of special materials (such as geotextiles) which resist soil clogging,
and by a design that provides an adequate total area in square feet for soil contact.
Each product manufacturer should be expected to provide an installation manual for the product
that you are going to use. The list below is generic and incomplete as site specific and product
specific details can't be provided here.
Perform a site survey to determine the size, layout, and materials needed. The manufacturer
indicate the disposal area provided by the product (per linear foot, for example) but your engineer
and installer need to evaluate your soils and daily wastewater usage to determine the amount
of leaching area needed for your site.
Tables of field sizing and soil percolation test
procedures are provided
Obtain local building code or board of health requirements
As with any wastewater disposal field, never drive equipment in or over the trenches. Compacting
the soil (or after installation, damaging the drainage components) will reduce the absorption
system capacity or may destroy it completely.
Some systems such as Infiltrator Inc. chambers,
have been tested to meet an H-10 engineering rating (16,000 lbs / axle), so occasionally if a
system built using some chamber products are driven over it won't necessarily be an issue. But
Infiltrator Inc. 's technical experts do not recommend constant vehicle traffic over anything but
their heavier duty H-20 chambers.
These disclaimers notwithstanding, it remains a better practice
to keep all traffic off of septic fields. And even where
septic equipment has been described as rated for vehicle traffic, heavy equipment
traffic can cause some surprising
collapses that can be costly to repair as shown in THIS PHOTO.
Some sites may need a curtain drain or other special measures to redirect surface or subsurface
runoff away from the effluent/wastewater absorption area.
Hancor Technology, INSTALLATION GUIDELINES FOR GRAVELLESS PIPE
FOR SEPTIC TANK LEACH FIELDS [PDF] (20056), Hancor Technology, Website: http://www.hancor.com/product/Gravelless_Septic_Design.html Tel: 888-FOR-PIPE
retrieved 2019/02/11 original source: https://www.lawsupply.net/storm_drains/Hancor/gravelless_pipe_install.pdf
Excerpt: As an alternative to gravel filled soil absorption trenches for septic tanks, the Hancor Gravelless
Pipe system is recommended.
Corrugated high density polyethylene pipe is factory inserted in a
synthetic filter material of Cerex® Type 25 protective wrap. It is available in both 8” and 10”
diameters (inside) and in standard 20’ lengths.
Hanson, Adrian, Ph.D., P.E., Craig Runyan, Bruce Lesikar, A HOMEOWNERS GUIDE:
INSTALLING A SEPTIC TANK AND DRAINFIELD [PDF] (2006), New Mexico Environment Department, Tel: 1-800-219-6157, retrieved 2019/02/11 original source: https://www.env.nm.gov/wp-content/uploads/2017/08/Homeowner-Notebook-final-2006.pdf
This guidance is restricted to the Homeowner installing a conventional septic tank and
drainfield system for their primary residence. It is also restricted to system receiving less
than 2000 gallons/day and no more than 500 gallon/day/acre of liquid waste. Includes details on installing or constructing a gravelless septic system.
Includes construction details for gravelless septic systems.
This publication explains how gravelless drainfields work and gives drainfield sizing and installation information for a home. It is not intended to provide all information needed to design a gravelless drainfield for a particular site or situation or to guarantee compliance with Nebraska regulations.
Includes formula to convert required conventional drainfield size in square feet of trench area to length of trenches required when using a gravelless pipe.
Basic formula: Liner Feet of Gravelless Drainfield Trench = [Sq.Ft. Required Standard Drainfield Area] / (0.75 x pipe diameter in ft x 3.14]
Infiltrator Systems, Inc. provides chamber products and geotextile septic products: Tel: 800-718-2754 Old Saybrook CT USA.
Website: http://www.infiltratorsystems.com/ or 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475
860-577-7000 -
1-800-221-4436
For more detailed design information, please contact
Infiltrator Water Technologies at 1-800-221-4436
NESC: GRAVELLESS SEPTIC DESIGN [PDF] Pipeline, NESC, National Envirobnmental Services Center,Box 6893, West Virginia University
Morgantown, WV
26506-6893 USA, Email: info@mail.nesc.wvu.edu Tel: (304) 293-4191 retrieved 2019/02/11 original source: http://www.nesc.wvu.edu/pdf/WW/publications/pipline/PL_SU01.pdf copy on file as Gravelless-septic-deisign-NESC.pdf
US EPA, DECENTRALIZED SYSTEMS
TECHNOLOGY FACT SHEET
SEPTIC TANK LEACHING CHAMBER [PDF] (2000) Municipal Technology Branch
U.S. EPA
Mail Code 4204
1200 Pennsylvania Avenue, NW
Washington, D.C. 20460 USA retrieved 2019/02/11 original source: https://www.epa.gov/sites/production/files/2015-06/documents/septic_tank_leaching_chamber.pdf
Excerpt: A leaching chamber is a wastewater treatment system
consisting of trenches or beds, together with one or
more distribution pipes or open-bottomed plastic
chambers, installed in appropriate soils.
These
chambers receive wastewater flow from a septic tank
or other treatment device and transmit it into soil for
final treatment and disposal.
WA DOH GRAVELLESS EFFLUENT DISTRIBUTION PRODUCTS [PDF] (2013) Recommended Standards and Guidance for Performance,
Application, Design, and Operation & Maintenance, Washington State DOH, Wastewater Management Section,
Post Office Box 47824
Olympia, Washington 98504-7824 USA, Tel: 360.236.3330
FAX: 360.236.2257
Email: wastewatermgmt@doh.wa.gov retrieved 2019/02/11 original source: https://www.doh.wa.gov/Portals/1/Documents/Pubs/337-005.pdf
Consultants or suppliers in this field can be listed at our alternative septic designers page at no charge by contacting me.
Gravelless Septic Design using Poly-Wrapped Pipe
While polyethylene wrapped or peforated-plastic-wrapped plastic pipe is discussed in older no-rock septic system design manuals, the use of poly-wrapped pipe for gravel-less septic effluent disposal has, in our OPINION, been eclipsed by the use of geotextile-wrapped pipe instead.
As of May 2020 it was difficult to even find a vendor selling this product type.
InspectApedia.com has no
financial or other relationship with any suppliers listed at our website and we do not endorse specific products. No fees or costs are involved in product source listings. CONTACT us to add information.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Questions & answers or comments about gravelless or no-rock or chamber type septic absorption field site requirements.
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
Crumpler Plastic Pipe, Inc. Crumpler provides fabric-wrapped drainage piping 800-334-5071 Roseboro NC USA - "No-Rock TM Septic-Leachate drainpipe systems" are available in 8" and 10" systems.
Pennsylvania State Wastewater Treatment Fact Sheet SW-161, Septic System Failure: Diagnosis and Treatment
Pennsylvania State Wastewater Treatment Fact Sheet SW-162, The Soil Media and the Percolation Test
Pennsylvania State Wastewater Treatment Fact Sheet SW-l64, Mound Systems for Wastewater Treatment
Pennsylvania State Wastewater Treatment Fact Sheet SW-165, Septic Tank-Soil Absorption Systems
Document Sources used for this web page include but are not limited to: Agricultural Fact Sheet #SW-161 "Septic Tank Pumping," by Paul D. Robillard and
Kelli S. Martin. Penn State College of Agriculture - Cooperative Extension, edited and annotated by Dan Friedman (Thanks: to Bob Mackey for proofreading the original source material.)
Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006). Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text I recommend for professionals--DF.
Design Manuals for Septic Systems
US EPA ONSITE WASTEWATER TREATMENT SYSTEMS MANUAL [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems,
Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers.
U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
"International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
"Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental
Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.