InspectAPedia®

Wet basement leads to mold (C) Daniel FriedmanWet Basement Dryout / Prevention
How to Stop or Prevent Basement Leaks & Water Entry

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.


Wet basement prevention:

This article discusses methods for preventing wet basements by attention to multiple best construction practices, including the basics of foundation waterproofing, poor site drainage, bentonite clay for basement waterproofing, foundation membranes to prevent leakage, foundation drain tiles, proper backfill, and proper finish grading.

A case study of a foundation collapse is described and we offer a few simple steps that might cure a wet basement without major work. A case study of a flooding basement, a rotted piano, and clogged gutters describes how home buyers were fooled into thinking they were buying a home built over a stream.

We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

How to Prevent a Wet Basement - causes and cures for basement water entry may be more basic and easy than you think

Foundation collapse (C) DanielFriedmanWet basement prevention steps discussed here include:

Article contents

Sketch at page top and accompanying text are reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss.

Wet Conditions Lead to Building Foundation Collapse

Wet basement or leaky basement prevention and cure  (C) Daniel FriedmanThis article begins with a pair of foundation collapse case studies, describing poor site drainage and wet soils that led to the foundation bursting into the home. Our photo (left) shows an example of severe foundation damage and ultimate collapse due to water and wet soils outside the foundation wall. Mr. Bliss points out several factors that led to two foundation catastrophes that he investigated:

Bliss notes that foundation leaks are said to cause more callbacks than any other problem in new home construction. Some building sites with good natural drainage are unlikely to result in a leaky basement even if the builder does not follow all of the best foundation water entry prevention steps during construction and site work. But others are a catastrophe waiting to happen - or as above, a catastrophe that has already happened.

Living With a Basement that Floods is Unnecessary and It's a Bad Idea

Wet basement leads to mold (C) Daniel FriedmanThe Two Tall Foot Piano

Living with periodic basement flooding - which some people manage, is not a great strategy, risking moisture-related damage such as toxic mold contamination (photo at left), building rot, termite damage, or even shorter roof shingle life.

The epitome of the "make it work" approach that I find troubling is wet basements.

People will install a $15,000. internal trench and drain system to "dry out" their chronically wet basement before first noticing that outside the gutters and downspouts spill right by the foundation wall, and inside we see water stains originating high on the basement wall, confirming that source of moisture. Instead we install a "fix" that first lets the water come into the building (where secondary problems of moisture will continue), then drain it away.

One of our clients (DJF) lived for thirty years in a house that flooded repeatedly in wet weather.

Many years ago I was hired to inspect a house for sale. The owners were told by their realtor they really ought to look into fixing their flooding basement before putting the home on the market. The basement had been chronically wet, flooding to several inches each time it rained, since before the owners bought the home 25 years before.

At my inspection the basement was full of 30 years of accumulated stuff, most of which was soaked and rotted. There was an upright piano that whose legs had rotted off - the piano had gradually settled down to the floor and just its top two feet remained.

"I'm Just Washing the Basement Walls" the home seller said.

When Mr. owner was looking at the home and liked it his wife wanted to come up from New York City to see it. They called the owner the next day. It was raining. "Today is not a very good day" the owner said. "I'm kind of busy". They insisted. Owner acquiesced.  On their arrival, in pouring rain, the buyers, naive city dwellers who'd never owned a house, found the owner, in the basement, standing in 24" of water. He was  wearing hip boots, and with a garden hose hooked up he was "spraying" the basement walls.

"What are you doing? " they asked.  --- I would have asked "What the hell are you doing???"

"I'm washing down my basement walls" was his explanation."I do this once in a while. Today seemed like a good time."

The buyers were not the least suspicious. They didn't think this was an odd rainy-day activity. They bought the house with the very clean basement walls.

The house is built over an old stream bed, he explained

Soon however, the new owners complained to the old owner that every time it rained their house had a basement flood. He explained that well the house was "... built over an old stream bed, and when it rains the stream rises into the basement - there's really nothing to be done about it."

Starting by noticing that basement leak stains originated high on the foundation walls I was sure that even if there was an underground stream, basement water was also coming off of the roof or from bad surface drainage.

Outside I found that a concrete patio had been poured against the foundation wall, later settling and tipping towards the home.

Inside the basement I saw huge water streak stains running down the rear basement wall at each of three basement grade-level windows.

Tall pines near the home made sure that the house gutters were constantly clogged with pine needles and clogged, overflowing onto that patio at every rainfall. Water ran across the patio and down through the basement windows and inside, down the foundation wall onto the floor. Interestingly I did not see other water entry marks elsewhere on the basement walls.

A simple experiment of cleaning the gutters and temporarily routing the downspouts well away from the home using above-ground flexible extensions was enough to immediately stop the basement water entry.

Fixing the in-slope patio was also needed to handle the heavy rainfall case.

Steps to Prevent Basement Water Entry - the Basics

Soil Testing Predicts Soil Drainage Ability

For new construction, start with a few soil tests to understand what the house is being built upon. Any civil engineering manual will include a soil guide describing soil types and their drainage characteristics. Watch out for clay soils and silts that are unstable and expand when wet or frozen.

Conduct a soil percolation test to get an accurate idea of how soils drain around the home. If a septic system is to be installed you're going to need soil perc tests anyway.

See SEPTIC SOIL PERC TESTS and PERC HOLE SPECIFICATIONS. Remember that if your perc tests are performed in the dry season you may get over-optimistic results. And if living space in the home is going to include below-grade areas, consulting with a soils engineer may be good insurance.

Water Entry Prevention Priorities

Inslope grade makes site drainage difficult (C) Daniel Friedman

Our photo (left) shows a home with an in-slope grade facing the house wall. It would have been relatively easy to install a swale draining hillside water and roof spillage around the left side of the home in this picture.

Instead the owners suffered decades of wet basements until the wet conditions made the home sills so attractive to termites that major structural damage had occurred.

Effective Foundation Waterproofing Method Details

Foundation Drainage Mats & Geotextiles for Foundation Waterproofing

Foundation drainage mats and geotextiles (C) Carson Dunlop Associates

As Carson Dunlop Associates' sketch (above) and our photos (below) illustrate, proper installation of a combination of damp proofing, a drainage mat, and a geotextile to keep the drainage mat from becoming clogged by soil particles can be effective in keeping roof spillage and surface runoff from penetrating the building foundation walls.

Watch out: even this approach won't prevent basement or crawl space water entry if groundwater levels are so saturated that they are rising up beneath the basement floor slab.

Foundation waterproofing (C) Daniel Friedman Foundation waterproofing (C) Daniel Friedman

Sealing Foundation Walls: damp-proofing vs Waterproofing

Details about water barrier coverings for foundations are
at
 WATER BARRIERS, EXTERIOR BUILDING.

Also see SEALERS, Basement Floor & Wall Moisture. Excepts are below.

Basement foundation sealer (C) Carson Dunlop Associates

True foundation waterproofing: for poorly drained soils, investigate true foundation waterproofing, such as heavy textured plastic or rubber membranes that are placed against the foundation wall to form a drainage layer to conduct roof spillage or ground water down the exterior of the foundation wall and into a foundation drain system to carry water safely away from the building.

Our foundation waterproofing system photographs above show (photo above right) and also Carson Dunlop Associates' sketch (left) show the use of a plastic membrane, protected by a geotextile to combine good water drainage down the foundation wall (and into the footing drains) with gravel backfill to nearly the top of grade (photo above left).

This basement waterproofing system was installed on a home that had suffered recurrent basement flooding due to a combination of in-slope grade at the rear and right side of the home combined with improperly installed and non-working footing drains, aggravated by wet soils in the area.

See BASEMENT HEAT LOSS for a discussion of foundation and basement insulation methods.

See POLYSTYRENE FOAM INSULATION for a guide to using this material in below-grade applications.

See TERMITE SHIELDS vs TERMITICIDE for a discussion of avoiding insect damage when foam insulating board is used below or at ground level.

Details about water barrier coverings for foundations are
at
 WATER BARRIERS, EXTERIOR BUILDING

Foundation Footing Drain Details to Prevent Basement Water Entry

Footing drain to daylight (C) Daniel Friedman

Foundation drainage - drain tiles also called footing drains and by some folks "French drains" (a mistake - see FRENCH DRAINS for DOWNSPOUTS),: water flows in the path of least resistance.

Perforated 4-inch PVC or flexible ABS are the least costly and most foolproof foundation drainage conduits. Foundation drains should pitch at least 4 inches in every 100 feet of length.

The top of the foundation drain, should be below the top of the finished basement or crawl space slab.

From the low corner of the building, the foundation drain should continue to daylight or, if permitted by local codes, to a storm sewer, so that water will drain away from the building without relying on an electrical sump pump or other magic.

 

Details about foundation drains or footing drains are found
at
 FOOTING & FOUNDATION DRAINS


Foundation Drainage: backfill details

Footing Drain details (C) Daniel Friedman

Bury the footing drains in gravel, both under and above the drain tiles. Extend the gravel backfill at least two-thirds of the way to the top of finished grade.

Gravel helps water flow easily into the drain system instead of seeking a way into the building, and the removal of water outside the foundation wall also avoids foundation collapse later

. The gravel size needs to be larger than the holes in the drain tiles.

Our sketch (left) shows a less than optimum footing drain installation because the artist placed soil too close to the drain pipe.

More details about foundation drains or footing drains are found at FOOTING & FOUNDATION DRAINS

Eliminate Exterior Sources of Water that Cause Building Leaks, Water Entry, Flooding

Details about eliminating exterior sources of foundation leaks and building water entry are
at
 EXTERIOR WATER SOURCE ELIMINATION . Check and correct these sources of building water entry:

Finish Grading to Prevent Foundation Leaks & Water Entry

Swale used to control surface runoff (C) Carson Dunlop AssociatesDetails about proper site grading to handle surface runoff and groundwater, including swales (shown below) are at GRADING, DRAINAGE & SITE WORK. Excerpts are below.

Swales: if one or more sides of the building face an upwards sloping hill, slope the finish grade away from the building for at least 10-15 feet, and then shape the finish grade at that point into a swale that itself continues to carry water around to the downhill side of the building.

A swale, illustrated by Carson Dunlop Associates' sketch at left, is a nice word for a "gentle ditch" - it does not have to be deep.

Simple Retrofit Repairs Can Cure Basement Leaks

Foundation crack leak (C) Daniel Friedman

 

 

Find and Clear Clogged Footing Drains

Details about installing, finding, and repairing foundation drainage systems are at FOOTING & FOUNDATION DRAINS. Excerpts are below.

Clogged footing drain (C) Daniel Friedman Clogged footing drain (C) Daniel Friedman

Find the end of the footing drain system that used to drain to daylight - it may have become buried with mud or covered by backfill. Clear it open and check the end for water flow in wet weather. Our photo (above left) shows the footing drain that was excavated and removed at the home of a client whose house suffered recurrent flooding. The old footing drain was totally impacted with mud.

The photo at above right shows the ends of three new footing drains that were installed and carried to daylight. We remained a little nervous about just what the builder used for backfill - notice that silty mud coming out of the new drains? They may not have a long life

Use an Intercept Drain at In-Sloping Driveways and Walks

Intercept drain at garage (C) Daniel Friedman

Add an intercept drain at the entry of garages into which a paved driveway is sending water whenever it rains.

If you are planning to re-pave a driveway, that's a great time to go to the trouble of cutting in and installing a drain that prevents water from flowing into the garage.

Connect the intercept drain to a storm drain or to a new buried drain line that slopes to daylight well away from the building.

Don't connect the intercept drain to the building footing drain system - you may overload the footing drains and cause basement leaks.

Basement Perimeter Drain Systems for Basement De-Watering: Installing & Inspecting "French Drains"

Details about interior perimeter drain systems such as B-Dri™ and Beaver Basement™ are found at PERIMETER DRAIN SYSTEMS. Excerpts are below.

Some people call an interior perimeter drain used for basement or crawl space de-watering a "French Drain". Whatever you want to call it, an interior perimeter drainage system cut into the basement or crawl space floor can effectively stop basement or crawl space flooding - or can it?

Wet basement cure: interior drain system Carson Dunlop Associates

 

An interior drainage system can indeed work to keep water off of the floors, and properly installed it can also resist sending problematic high moisture levels into the building as well.

But first you should check and repair obvious outdoor water entry sources that send water through the building foundation walls.

Carson Dunlop Associates' sketch (left) shows t approaches to installing an interior drainage system

 

Our home page for diagnosing and curing foundation leaks and wet basements or crawl spaces
is WATER ENTRY in BUILDINGS.

Readers should also
see BASEMENT LEAKS, INSPECT FOR and BASEMENT WATERPROOFING.

Readers needing more extensive guidance on preventing or fixing basement leaks and moisture should
see BASEMENT LEAKS, INSPECT FOR,
or if your building includes areas over crawl spaces,
see CRAWL SPACE DRYOUT - home.

If your building has been flooded, see FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP. Contact us to suggest text changes and additions and, if you wish, to receive online listing and credit for that contribution.

Here we include solar energy, solar heating, solar hot water, and related building energy efficiency improvement articles reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. The original wet basement prevention article (linked-to below) has been adapted and expanded in this document.

The article above paraphrases, quotes-from, updates, expands and comments on an original article original article (see links just above)"The Almost-Too-Tight-House" by Steven Bliss.

Keeping Basements Dry: Wet Basement Prevention - part 1 [PDF form], use your browser's back button to return to this page &
Keeping Basements Dry
: Wet Basement Prevention & Cures
- part 2

Reader Question: Which is best for basement water proofing: bentonite clay injection outside or crack sealing inside?

The little Dutch Boy, Wikipedia creative commons 2012I am getting mixed recommendations from local contractors here in the Chicaoland area. Some contractors want to stop my basement seepage by using a Bentonite clay injection rom the outside and some contractors want to use epoxy/ urethane foam to repair the crack. Which procedure will last longer and what is the normal price to fix one crack using bentonite and the price to fix one crack using epoxy/ urethane. - Jillian 5/11/12

Reply:

Before choosing a solution to a wet basement or crawl space, it is very important and useful to get an accurate and honest diagnosis of the cause of water entry in the first place.

The nature of the waterproofing measures or repair as well as repair cost to correct water entry due to a misplaced downspout or roof gutter overflows is very different from water entry due to in-slope grade outside of a building or (more rare) construction of a building placed too deep into soils with a high seasonal water table. [Photo at left of the Little Dutch Boy placing his finger on a hole in the dyke, Wikipedia creative commons][5]

The best method for stopping basement water entry is neither of the options you gave: our first choice is always to divert outside water away from the building. Usually, and especially if the outside water source is roof runoff or downspout drainage, this best method is also the least costly.

The second best method for stopping basement water entry, in terms of effectiveness in my OPINION, is to seal the exterior of the foundation by any of a variety of methods, of which the bentonite clay approach has a long history of use and usually of effectiveness.

It's also usually a more costly approach than sealing a single crack indoors. Because building foundations are not constructed to function as a waterproof boat hull, making a foundation really waterproof can be a challenge, and expensive.

The Procedure & Effectiveness of Bentonite Clay Injection for Waterproofing Foundations

Bentonite clay injection into soils around a home is one of many foundation waterproofing methods. Bentonite, a clay dominated by the mineral montmorillonite (synonym "smectite") is a naturally-occurring geological deposit that occurs worldwide, but bentonite mined in the U.S. in northeastern Wyoming and southeastern Montana is recognized world-wide as the purest sodium montmorillonite that is commercially available from a natural source.

"Numerous and extensive studies have documented the effectiveness off bentonite as an absorbent, buffer, barrier, or sealing agent against solute and liquid migration .... The impact of swelling soils with significant amounts of montmorillonite minerals has been extensively studied ..."[6]

In the bentonite clay waterproofing procedure, using a truck containing a thick colloidal mixture of bentonite and water, and using a high pressure pump, bentonite clay is injected into the soil at appropriate depths (from the foundation footing up) and intervals around the building foundation.

The bentonite clay, injected through a hollow one-inch diameter drilled or driven rod, is pumped into soils quite close to the building foundation wall, forms a water resistive barrier. The injected bentonite expands in all directions for about 12-inches (varying by soil conditions) from its pumping location and requires about 45-minutes to an hour to cure to a putty-like stable state that leaves the material in place..

Bentonite clay waterproofing companies point out that by injecting the bentonite close to the foundation wall, you may see some of the clay mixture seeping into the building through existing foundation cracks where it forms a sealant in the crack from outside the foundation wall and through the wall thickness as well.[11]

The appeal of the bentonite clay injection approach to waterproofing a leaky basement below a building is that it may be effective, and injecting clay into the soils around a building is far less disruptive than excavation to apply waterproof mats and a buried drainage system. How well the bentonite clay approach will work depends on more variables including soil and site conditions. [6][7][8][9][10]

The Effectiveness of Epoxy Crack Sealing in Foundation Walls

Photograph of polyurethane foam being injected into a concrete foundation crackThe third approach to basement waterproofing by interior surface crack sealing can be effective and cost-effective on a poured concrete foundation that is leaking only at one or a few very specific locations.

For concrete block foundations, for a foundation with many cracks, for a basement that has many water entry points, for a basement in which water enters at the bottom of the wall around a footing or interior floor slab, this approach, while least costly, is also likely to be least effective.

Details about sealing cracks in concrete walls or floors using epoxy or epoxy grouts are at SEAL CRACKS IN CONCRETE, HOW TO and at POLYURETHANE FOAM INJECTION where we give details for using polyurethane foam to seal foundation cracks.

Durability of basement waterproofing methods

Properly applied, both bentonite clay and epoxy crack sealing are very durable in the location where they are placed. Of course if you have a lot of water outside your foundation and you simply rely on the little Dutch Boy at the dyke who placed his thumb over the first crack that appeared, the risk is that the water simply finds another entry point.... then another.

The moral of the Little Dutch Boy story was that quick action and bravery averted a catastrophe. But it was the workers who came later to actually repair the dyke who were able to perform a lasting repair.[4]

 

...


Continue reading at WET BASEMENT PREVENTION or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see BASEMENT LEAKS, INSPECT FOR

Or see EFFLORESCENCE SALTS & WHITE DEPOSITS

Also see WET BASEMENT PREVENTION

and FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP where we include additional photos of basement water entry.

Or see:

Key Basement Dry-Out Articles

Suggested citation for this web page

WET BASEMENT PREVENTION at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to BUILDING LEAKS & WATER ENTRY

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman