This article provides manuals and contact information for Clean water systems, air chargers, pumps, water treatment & water softeners.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
Clean Water Systems & Aeration Systems
Water Treatment Equipment - air chargers, air pumps
Contact: Clean Water Systems, 2806-A Soquel Ave
Santa Cruz, CA 95062 USA, Website: www.cleanwaterstore.com Email: office@cleanwaterstore.com Tel: 888-600-5426 or 831-462-8500
The Air Charger Sulfur Filter 5900BT-AIR,
when properly applied, is an efficient and
cost effective system for the removal of
sulfur odors.
The Air Charger Sulfur Filter 5900BT-AIR
control valve maintains a compressed “air
pocket” in the top of the tank while the
system is in service.
As the water passes through the air pocket,
the sulfur is oxidized. Additionally, dissolved
oxygen is added to the water.
The Air Charger Sulfur Filter filter media bed
then removes the sulfur and odors from the
water.
Backwash is done by default at 2am
(programmable) 1 to 7 times per week
depending on the sulfur odors.
This will remove the now elemental sulfur
and, if present, light levels of iron as well.
The Pro Ox 5900-BT-AIR, when properly
applied, is an efficient and cost effective
system for the removal of iron and odor.
The Pro Ox 5900-BT-AIR control valve
maintains a compressed “air pocket” in the
filter free space top of the tank while system is
in service. As the water passes through the air
pocket, iron is oxidized. Additionally, dissolved
oxygen is added to the water.
The Pro Ox filter media bed then removes the
iron from the water.
The backwash rinse cycle
(usually done at night, every 2-4 days) will
remove accumulated iron and replenish the
filter media bed.
Each night a fresh pocket of air is drawn into
system to allow maximum oxidation.
... Note About Aeration
[Devices on a Water Softener, Iron Removal, Odor Removal system etc.]
The Pro Ox 5900-BT-AIR utilizes air, oxidation
and filtration for the removal of Iron.
You might notice a bit of tiny air bubbles in
the water during first week or so after
installation and this is normal but goes away
after installation.
Some well waters do not need aeration and
this feature can be turned off if applicable.
CLEAN WATER SOFTENERS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.