Bosch water heater age decoders, water heater manual sources.
In this article series we give details of how to de-code water heater age for all water heater brand. We also discuss the conditions, maintenance, and factors that affect how long a water heater can be expected to last.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Editor/Publisher - See WHO ARE WE?
A Bosch Water Heater Co tankless water heater data tagis shown here.
[Click to enlarge any image]
Depending on the age of your Bosch water heater, the dates of production or manufacture are found at different points in the serial number that you will find on the water heater's data tag - as given in the Bosch Serial Number reference guide PDF provided later on this page.
Two Bosch water heater serial number formats are common but you will already notice that these commonly-used Bosch age decoder formats do not exactly match the serial number of the LPG firedBosch tankless water heater data tag shown.
All-Numeric: 12345678 where 123 encodes production monty and year encoded by a table available from Bosch and replicated below.
What you will notice is that for each year the company uses a 3-digit code that incrases by 1 for each month of that year. So for 1996, of the 3 digit code 86 = 1996 and the months suffix 1 - 12 as shown in the table below.
For 1998 the year begins with 861 = 1998 January of 1998 while 872 = 1998 December
Similarly for 2002 the year begins with 381 = 2002 January while 392 = 2002 December
Bosch Water Heater All-Numeric Serial Number Decoder |
||||||||||||
Year | ||||||||||||
Month | 1998 | 1999 | 2000 | 2001 | 2002 | 2004 | 2004 | 2005 | 2006 | 2007 | 2008 | 2009 |
Jan | 861 | 961 | 081 | 181 | 281 | 381 | 481 | 581 | 681 | 781 | 881 | 981 |
Feb | 862 | 962 | 082 | 182 | 282 | 382 | 482 | 582 | 682 | 782 | 882 | 982 |
Mar | 863 | 963 | 083 | 183 | 283 | 383 | 483 | 583 | 683 | 783 | 883 | 983 |
Apr | 864 | 964 | 084 | 184 | 284 | 384 | 484 | 584 | 684 | 784 | 884 | 984 |
May | 865 | 965 | 085 | 185 | 285 | 385 | 485 | 585 | 685 | 785 | 885 | 985 |
Jun | 866 | 966 | 086 | 186 | 286 | 386 | 486 | 586 | 686 | 786 | 886 | 986 |
Jul | 867 | 967 | 087 | 187 | 287 | 387 | 487 | 587 | 687 | 787 | 887 | 987 |
Aug | 868 | 968 | 088 | 188 | 288 | 388 | 488 | 588 | 688 | 788 | 888 | 988 |
Sep | 869 | 969 | 089 | 189 | 289 | 389 | 489 | 589 | 689 | 789 | 889 | 989 |
Oct | 870 | 970 | 090 | 190 | 290 | 390 | 490 | 590 | 690 | 790 | 890 | 990 |
Nov | 871 | 971 | 091 | 191 | 291 | 391 | 491 | 591 | 691 | 791 | 891 | 991 |
Dec | 872 | 972 | 092 | 192 | 292 | 392 | 492 | 592 | 692 | 792 | 892 | 992 |
...
Alpha-Numeric: AB123456789 where 123 encodes production month and year encoded by a table available from Bosch and encoding year and month just as for the table given above.
Use the same table above once you've piced out the three nnn digits after the first pair of alphabetic characters such as AB shown abovce.
Also see
For Buderus water heater age determination, use the same serial number decoding as given above.
...
Continue reading at WATER HEATER LIFE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
BOSCH WATER HEATER AGE & MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Questions & answers or comments about how to find out the age of a heating appliance: water heater, heating boiler, heating furnace.
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.