GE / General Electric Air Conditioners, Mini Splits, Heat Pumps
Manuals, parts lists, wiring diagrams and company history and contact information for GE HVAC equipment:
Free downloadable manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps. Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturers who can provide that information for nearly all major brands of HVAC equipment.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Free GE Furnace, Heat Pump, Air Conditioner Installation & Service Manuals, Wiring Diagrams, Parts Lists
Below we provide GE / General Elecdtric heating & air conditioning history, manuals, data tags, manufacturer contact information and direct links to free downloadable installation, service, and users manuals, focusing on hard-to-find manuals for older models or discontinued equipment. We also provide links to the manufacturer's current model lists and literature.
GE's HVAC division was sold to Trane in 1982.
In 2016 General Electric sold its appliance business to Haier, a Chinese home appliance manufacturer for $5.4 billion. After 2016 GE no longer provides lighting, home appliances, cooktops, ranges, refrigerators, nor water heaters.
GE boiler or furnace age decoding guidelines are inconsistent but at least map to before and after the sale to Trane.
For older GE hydronic boilers, electric furnaces and similar heaters
With the caveat that you need additional information such as building age or notes on the equipment service tag or on paperwork stored nearby to guess the correct decade to which Y appears.
General Electric Air Conditioning was purchased by Trane in 1982 or by some sources 1981.
For GE heating boilers made after 1982 (or by some sources 1981) and sold by Trane may encode the equipment manufacture date in one of these formats:
123456YWW
Y is encoded as an alphabetic letter T (perhaps for Trane) for 1982
WW is the sequential week within year (01-52)
Photos above and below: a GE Oil Burner Master Control, CR 7865-A10B52 Stack Relay or "Protectorelay" as for sale on ebay in 2022
This is an obsolete control.
See
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
(May 26, 2020) Steve said:
I am inquiring the age of a General Electric Weathertron heat pump. See # 288677952
Model # BWB936A10002. Thank you.
This Q&A were posted originally
at AGE of HEATERS, BOILERS, FURNACES
Our best GE data tag decoding is found on the page above. Let me know what you think.
On 2018-08-03 by Phoebe
Great list of manuals! I am a historian and collector and I am looking for General Electric gas furnace product manuals that GE produced between 1968-1980. Would you happen to have any of those in your collection? Or does anyone know where I might find old GE furnace manuals? Thanks!
Sure, Phoebe, see
GE GENERAL ELECTRIC HVAC MANUALS
Also,
Carson Dunlop, Associates, Toronto, have provided us with (and we recommend) Carson Dunlop Weldon & Associates'Technical Reference Guide to manufacturer's model and serial number information for heating and cooling equipment
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on any number of copies of the Technical Reference Guide purchased as a single order. Just enter INSPECTATRG in the order payment page "Promo/Redemption" space.
...
Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
GE GENERAL ELECTRIC HVAC AGE, MANUALS, CONTACT at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website