Anthes Boiler Manuals, Parts Lists, Wiring Diagrams
Anthes / Intercity Boiler Manuals, parts lists, wiring diagrams for HVAC equipment: air conditioners, boilers, furnaces, heaters, etc.
We include links to contact information & free immediate downloads of example installation & repair manuals and wiring diagrams.
Page top photo: a Used Anthes Inter City Furnace that we found for sale at Hermanstools.com,
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Free Anthes Boiler Downloads of Manuals, parts lists, wiring diagrams. Direct Links to Free Downloads of Furnace Manuals, parts lists, wiring diagrams, age decoders.
Below we provide HVAC manufacturer contact information and direct links to free downloadable installation, service, wiring diagrams, and users manuals, focusing on hard-to-find manuals for older models or discontinued equipment. We also provide links to the manufacturer's current model lists and literature.
We include free downloads of air conditioner, boiler & heat pump manuals. We link to related lists of other installation & operation manuals for other building mechanical systems such as water heaters, water softenes, well & water pumps & controls.
Note: for page loading speed this index to HVAC manuals is spread across several pages, but all of the individual companies are listed on this page.
Anthes boilers were produced by the Anthes Foundry in Winnipeg, founded by Lawrence L. Anthes ca 1915. Lawrence Anthes' earliest patent recording was a Canadian patent No. CA 191047 for a temperature regulating device filed in 1918 and granted in 1919 (probably for the Anthes foundry).
LL Anthes along with Fred Ellis and George Pallister, under the aegis of the Anthes Foundry patented a hot air furnace as CA 376829 in 1938, and another as Canadian Patent CA 379539 in 1939.
Intercity Furnace (Inter City Gas Co.) (ICG), Winnipeg, Canada produced Anthes, Bullochs, & Furnasman equipment) was renamed as International Comfort Products (ICP) that was in turn purchased by United Technologies in 1999.
Also see the heater guides and manuals provided at
Typically on an Anthes brand boiler (a 1940's vintage heating brand Anthes Imperial Limited sold in Canada (the HGB 100), the U.S. and the U.K.) there is a 6-digit, all numeric, serial number.
123456
OR an alphanumeric serial number lik
ABC12
that encodes the equipment age, but currently, depending on where you ask (which website), you might have to pay to obtain that detail as we explain at the links given below.
First try this:
In at least some Anthes equipment, the manufacturing date is encoded in the serial number as follows:
YYWW567890
or in this serial number format:
XYYWW56790
(ignore the first alphabetic character, pick up the first four numeric digits, and decode them as YYWW as we illustrate here.
Use the first four numeric digits that form YYWW where YY is year of manufacture and WW is week of manufacture in that year.
The remaining numeric digits, usually 5, form a unique serial numer or manufacturing sequence number of the equipment.
For most Anthes or Inter-City Heaters you cany de-code the serial number to find the heater's age or year of manufacture using the serial number decoder I gave above and for which more details are found at
Typically on an Anthes brand boiler (a 1940's vintage heating brand Anthes Imperial Limited sold in Canada (the HGB 100), the U.S. and the U.K.) there is a 6-digit, all numeric, serial number. 123456 OR an alphanumeric serial number like ABC12
It's safe to estimate that your Anthes or Intercity boiler with a serial number in that format is 50 years old or older.
If the age decoding formats we gave above don't work for your boiler, take a look at the brand and serial number of (apparently-original) parts attached to the boiler such as the oil burner, burner motor, circulator pump, or other controls to find a serial number that can often get us in the right ballpark.
Here are two other Anthes HVAC aging guides that can help:
Note 1: Preston's Guide, Residential Replacement (HVAC) Sales, "Where Are They Now? Those Titans of the HVAC Industry ... Merged, Fallen by the Wayside, or Still Going Strong", http://www.prestonguide.com, retrieved 9/18/2013
Note 2: http://www.warmingupcanada.hvacrheritagecentre.ca/ history of Inter City Gas & Anthes.
Quoting: The unresolved problems in those early Canadian-made condensing furnaces were still secondary heat exchanger failure; lack of knowledge of and product for condensate removal; the appliances’ physical dimensions; and premature failure of the power exhaust gas venters selected.
For additional information about de-coding the data tag on Inter City Gas (I.G.C. HVAC equipment) also see the Carson Dunlop Assoc. Technical Reference Guide:
Anthes boilers were produced by the Anthes Foundry in Winnipeg, founded by Lawrence L. Anthes ca 1915.
Lawrence Anthes' earliest patent I found was a Canadian patent No. CA 191047 for a temperature regulating device filed in 1918 and granted in 1919 (probably for the Anthes foundry).
LL Anthes along with Fred Ellis and George Pallister, under the aegis of the Anthes Foundry patented a hot air furnace as CA 376829 in 1938, and another as Canadian Patent CA 379539 in 1939.
AG said:
I’m looking for help in finding a specification plate or manual for a Anthes intercity finance from 1974.
Yesterday I had a tech come to the house to clean the furnace. The tech tagged the furnace because the specification plate was missing and I can’t locate the furnace manual from 1974.
I now have 45 days to either provide the furnace manual or have a new furnace installed. If by the 45th day I haven’t they will shut off the gas. Any ideas how I can get my hands on a specification plate or furnace manual from a Anthes intercity finance from 1974? - A.G. 9/18/2013
My understanding from reading several historical notes & reports on furnace history is that Intercity Furnace (Inter City Gas Co., Winnipeg, Canada produced Anthes, Bullochs, & Furnasman equipment) was renamed as International Comfort Products (ICP) that was in turn purchased by United Technologies in 1999. Note 1
The Anthes Intercity furnace line was produced at least from the 1950's through the 1970's. In 1980 Intercity also produced an early condensing furnace - the Ultimate - that we've read did not perform well. Note 2
Anthes boilers and furnaces that are still older were produced by the Anthes Foundry in Winnipeg - discussed below.
You will find some websites online offering to sell parts for the Anthes Intercity Furnace under the new ICP brand. I'd try that approach to finding a manual; you may find someone who has one and can prepare a PDF - sorry but we don't have that manual ourselves or I'd post it for you. Here are some Anthes Intercity Furnace links that might help:
...
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
I need the belt size for our Anthes Furnace. It is a 1974 model. On 2021-02-04 by Terry Tinordi
Reply by (mod) -
@Terry Tinordi,
First check the manual for your specific Anthea model.
Also there are standard and easy procedures to find the size of a fan belt needed:
1. Measure the distance between the centers of the two drive shafts
2. Measure the diameter of the two pulleys
3. Your supplier, with those two measurements, can give you the right belt (looking it up in a table)
but
Watch out: also be sure that the profile of the belt in cross-section is proper for the shape of the vee or groove of the pulleys involved.
Hello, I had to give an estimate for a boiler, upon viewing the existing boiler, I was wondering the age of the boiler, could someone email me if he / she has an idea, it is an Anthes- Imperial bolier WO 14 4, thanks tonynewyork@live.ca 2017/09/16 Tony
Answer by mod
Tony,
Anthes boilers were produced by the Anthes Foundry in Winnipeg, founded by Lawrence L. Anthes ca 1915.
Lawrence Anthes' earliest patent I found was a Canadian patent No. CA 191047 for a temperature regulating device filed in 1918 and granted in 1919 (probably for the Anthes foundry).
LL Anthes along with Fred Ellis and George Pallister, under the aegis of the Anthes Foundry patented a hot air furnace as CA 376829 in 1938, and another as Canadian Patent CA 379539 in 1939.
You want to look at the serial number on your boiler.
Typically on an Anthes brand boiler (a 1940's vintage heating brand Anthes Imperial Limited sold in Canada (the HGB 100), the U.S. and the U.K.) there is a 6-digit, all numeric, serial number. 123456 OR an alphanumeric serial number like ABC12
It's safe to estimate that the boiler you saw boiler is no less than 50 years old and possibly, if it's a 1940's model, we're looking at a heater that's more than 75 years old.
For Anthes and a few other heater or boiler brands that have not come up with a clear age-decoder, take a look at the brand and serial number of (apparently-original) parts attached to the boiler such as the oil burner, burner motor, circulator pump, or other controls to find a serial number that can often get us in the right ballpark.
We are looking to replace the thermocouple on am anthes furnace HCB45A sn 22282. Help please On 2020-12-30 by Jd
JD
Thermocouples are a rather standard device. You should be able to obtain a replacement from your local plumbing & heating supplier or even online. Just check that the replacement thermocouple tubing length is at least as long as the original. Longer is OK you just leave the extra length as a bend or coil placed out of the way below the gas valve.
Details are at
THERMOCOUPLE REPAIR / REPLACEMENT
Take a look at that article and let me know if you have further questions.
...
Continue reading at MANUALS for HEATING & A/C SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
ANTHES BOILER AGE MANUALS & PARTS GUIDES - at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
If you posted comments here and no longer see what you wrote, please check for your comment in the Reader Q&A found above on this page.
In addition to any citations in the article above, a full list is available on request.