InspectAPedia®

Half round gutter hanger (C) Daniel Friedman Guide to Roof Gutter Hangers & Attachments

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

This article explains how gutters are attached to or supported on buildings, describing different sorts of gutter hangers and their pros and cons. We also discuss the recommended sized or capacity of roof gutters as a function of the size of roof area being drained. This article series discusses how to choose, install, diagnose & maintain roof gutters & downspouts, & roof drainage systems to prevent building leaks and water entry.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

How Are Gutters Attached to the Building? Types of Gutter Hangers

Gutter and Downspout Details (C) Carson Dunlop Associates

[Click to enlarge any image]

Gutters won't survive the occasional extra weight of water, wet leaves, ice or snow that weigh down gutters when they have not been kept cleaned. But you can increase the durability of the building's roof gutter system by using enough connections to fasten the gutters to the structure so that those occasional extra stresses can be endured.

The sketch at left informs us that

  1. Roof gutters should slope at least 1-inch in every 200 inches of run
  2. Roof gutters should be secured to the building every 2-3 feet.

Sketch courtesy of Carson Dunlop Associates.

Gutter attachments to the building vary by gutter materials and design as we illustrate below.

Gutter and Downspout Details Carson Dunlop Associates

For metal gutters and most plastic gutters, the gutter is secured to the fascia board, or to structural members such as the tails of rafters, using

  1. an exposed bracket and strap (works well but it's easy to knock off the strap when cleaning the gutters),
  2. a spike and ferrule (cheap, easy, but tend to work loose and pull out) or
  3. hidden gutter fasteners (work well and are secure provided proper fasteners are used and are screwed to sound building surfaces).

Sketch courtesy of Carson Dunlop Associates.

Below we show the type of gutter hanger used for half-round gutters (below left) and hidden gutter hangers (below-right).

Half round gutter hanger (C) Daniel Friedman Copper Gutter (C) Daniel Friedman

Recommended Roof Gutter Sizes

As Carson Dunlop Associates points out in their Home Reference Book

Four-inch gutters are good for relatively small roof areas; however, five-inch gutters are preferred because of their additional capacity. Five-inch gutters are also less likely to allow water to overshoot the gutters when the water is draining off a steeply pitched roof.

While "rules of thumb" for both gutter size and number of downspouts needed often are based simply on the length of roof edge that is being drained, this approach is flawed in that it fails to consider the total roof area that is being drained.

A roof that is very small in total area, even if very long, may get along just fine with a smaller 4-inch gutter, while a much larger roof area with the same length of roof eaves needs a 5-inch gutter or larger.

Also, as our (photographs below illustrate) odd roof shapes or complex multiple roof designs may end up sending a large volume of water from multiple surfaces into a relatively short gutter length that cannot possibly handle that volume. The result will be spillage by the building foundation and a high risk of a wet basement.

Copper Gutter (C) Daniel Friedman

Half round gutter hanger (C) Daniel Friedman

Some homeowners install larger gutters and leaders not because of difficulty handling the volume of water being drained, but because they believe that they'll have to clean the gutters less often. Nevertheless, it doesn't take a much larger handful of leaves or debris to clog a large downspout than a smaller one.

Overflowing Gutters?

Before Installing a Larger Gutter System: Things to Check if Your Gutters are Overflowing

In sum, if the area of roof being drained is larger than usual and there are no defects in the gutter or downspout system, then if gutters still overflow during heavy rainfall you may need to install a larger gutter system.

Also see DRIP LINES INDICATE OVERFLOW This article describes ground-level visual clues that tell the story of the history and location of gutter overflows at a building.

Roof Gutter or Eaves Trough Inspection & Repair Articles

...


Continue reading at GUTTER REPAIR, LEAKY JOINT or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Or see SAGGING GUTTERS

Suggested citation for this web page

GUTTER HANGERS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to ARTICLE INDEX to GUTTERS & DOWNSPOUTS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Questions & answers or comments about roof gutter hangers, straps, & supports: installation & repair.

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman