InspectAPedia®   -   Search InspectApedia

Photograph of aluminum electrical wiring in a home. Aluminum Wiring Inspection Guide
How to check a building for aluminum electrical wire hazards

This article contains additional notes on aluminum wiring intended for home inspectors.

Here we describe how to check a building for the presence of aluminum electrical wire: a fire hazard if the wire has not been properly repaired.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?

Home Inspectors' Concerns Regarding Twist-On Connectors for Aluminum Wiring Repairs

Photograph of ALUMINUM WIRE  - Recognizing aluminum wiring may be possible where nonmetallic wiring is visible such as in attics or basements.This article on how to check a home for the presence of aluminum wiring is a companion to ALUMINUM WIRING IDENTIFICATION - how to recognize or identify aluminum wire and when was it used in homes?

We also cite U.S. CPSC oncerns with aluminum wiring hazards and problems with some of the aluminum wiring repair connectors on the market raise safety concerns.

Home inspectors should review the CPSC recommendations for and against various aluminum wiring repair connectors - we give a live link to the US CPSC publication No. 516 below.

In addition to the re-wiring option, there are aluminum-to-copper connection products that perform well for aluminum wiring repair using the copper-pigtailing method.

Based field experience with the inspection of in-service residential electrical wiring, the availability to consumers of any comparatively low-cost "solution," if it is approved for only narrow, specific, limited use, may result in widespread do-it-yourself misapplication and possibly dangerous use of the device.

We've already seen this problem where we've found use of common twist-on connectors as a "retrofit" made by homeowners and electricians who have heard that there is a "pigtailing" "fix" but who have not read the CPSC literature or who considered the AMP TYCO COPALUM aluminum wiring repair too costly or too difficult to obtain in their area.

Improper use of connectors can actually increase the probability of a fire since owners think the aluminum wiring hazard has been eliminated and may ignore important signs of a looming failure.

Ordinarily the CPSC does not "approve" nor "disapprove" specific products. An exception was the case of the "Copalum connector" for aluminum wiring, probably because another product of equal reliability had not been listed, and because of the inherent dangers of improper retrofit attempts.

Misunderstanding: ASHI Does Not Approve Products

In a 7/27/95 conversation with a representative from the Ideal corporation, the author was told that the American Society of Home Inspectors (ASHI) was in the process of approving these connectors. This appears to have been a misunderstanding. Home inspectors who may have heard that such an approval was forthcoming should be advised that ASHI does not approve (nor disapprove) specific products.

7 Points of Key Aluminum Wiring Repair Advice Home Inspectors Should Give to their Clients

  1. Watch out: Aluminum Electrical Wiring is a Fire Hazard in Homes -

    see ALUMINUM WIRING SAFETY ASSESSMENT - CPSC.

    For help in recognizing aluminum electrical wiring in homes

    see ALUMINUM WIRING IDENTIFICATION.
  2. Aluminum Electrical Wiring repairs in a home where that work has not been performed will be a significant expense
  3. Aluminum wiring repairs should not be deferred, as the risk increases with age and use of the electrical system; meanwhile be sure that the home has working smoke detectors, and turn off any circuits behaving oddly.
  4. Aluminum wiring repairs should be performed only by a licensed electrician who is well informed about the correct repair methods. Using an improper repair method may actually increase the risk of a fire.

    See ALUMINUM WIRING REPAIR ELECTRICIANS
  5. Do use one of the following aluminum wiring repair methods:

    Replace all of the aluminum wire with copper.

    Use the AMP / TYCO COPALUM connector to pigtail copper extensions to every aluminum branch circuit wire end

    See PIGTAILING USING AMP "COPALUM" CONNECTORS.

    Use the AlumiConn™ connector to pigtail copper extensions to every aluminum branch circuit wire end

    ALUMINUM WIRE AlumiConn describes using this device and how it is connected, wired, and torqued.

    Details of procedures to make aluminum wiring safe are

    at ALUMINUM WIRING REPAIR METHODS - home
  6. Do not use any of these aluminum wiring repair methods
    1. COALR or CU-AL devices -

      see ALUMINUM WIRING REPAIR COALR & CU-AL
    2. Twist-on connectors such as the Ideal-65 purple "twister" or other connection methods not recommended by the CPSC -

      see ALUMINUM WIRING REPAIRS NOT-RECOMMENDED
  7. Feel free to copy and place the following ALUMINUM WIRIING SUMMARY free to copy page at your website or to make printed copies to give to consumers at no charge

...

Continue reading at ALUMINUM WIRING IDENTIFICATION or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

ALUMINUM WIRING GUIDE for HOME INSPECTORS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to ELECTRICAL INSPECTION & TESTING

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT