InspectAPedia®

Drawing showing the key parts to a modern air conditioning compressor/condensor unitAir Conditioner / Heat Pump Repair Procedures
How to Fix an A/C or Heat Pump not working, won't start, not cool, weak airflow, noises, etc

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.


Air conditioner & heat pump repair procedures:

The articles listed below describe in detail the inspection, troubleshooting diagnosis, and repair of all types of residential and light commercial central air conditioning and heat pump systems.

Page top image and airhandler image below were provided courtesy Carson Dunlop Associates.



Green links show where you are. © Copyright 2017 InspectApedia.com, All Rights Reserved.

A/C - Heat Pump Repair Guides: How to diagnose and fix an air conditioning system that is not working

Loose blower assembly pulley or belt reduces airflow (C) Carson Dunlop AssociatesList of A/C or Heat Pump Diagnostic Procedures

Since the failure of an air conditioner to turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply, or even loss of air flow entirely can be due to a variety of problems with one or more components of an air conditioner or air conditioning system, after reviewing the lost air conditioner cooling diagnosis procedures described in this article, be sure to also review the diagnostic procedures at each of the individual air conditioning diagnosis and repair major topics listed just below.

Electrical problems on HVAC systems: Keep in mind that despite the depth of technical detail you will find here about all components of air conditioners and heat pumps, most service calls for non-working air conditioners or heat pumps turn up an electrical problem. So if your A/C system is just not working at all be sure to check all of our electrical and control setting suggestions first.

Mechanical problems on HVAC systems: tend to fall into these groups: refrigerant leaks, dirty condenser coil or unit, dirty evaporator or cooling coil, or burned out (or hard-starting) compressor motors. We have also seen a number of problems with fans and fan motors in both the compressor/condenser unit and in the air handler/blower fan unit. Some of those fan problems are mechanical - like a loose fan belt or blade.

If your air conditioning or heat pump system has completely lost cooling capacity or if it plain won't start you can jump right to AIR CONDITIONER NOT WORKING or select one or more of the diagnostic articles listed below.

Honeywell room thermostat

...


Continue reading at AIR CONDITIONER DIAGNOSTIC CHECKS or select a topic from closely-related articles below, or see our complete INDEX to RELATED ARTICLES below.

Suggested citation for this web page

REPAIR GUIDES A/C / HEAT PUMP at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.

INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia


...

Frequently Asked Questions (FAQs)

Click to Show or Hide FAQs

Ask a Question or Search InspectApedia

Use the "Click to Show or Hide FAQs" link just above to see recently-posted questions, comments, replies, try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Comment Box is loading comments...

Technical Reviewers & References

Click to Show or Hide Citations & References

Publisher's Google+ Page by Daniel Friedman