Tankless Water Heater Life Expectancy, Uses & Applications Demand Water Heaters or Instantaneous Water Heaters or
Endless Hot Water Systems
POST a QUESTION or COMMENT about the best or most effective use of tankless water heaters, demand water heaters, & point of use water heaters & about tankless or demand water heater life & warranty periods
What is the life expectancy of a tankless water heater, & what are the types & applications of tankless water heaters - demand water heaters or instantaneous water heaters.
This article describes typical and special applications of tankless or instantaneous water heaters in a variety of uses, and we distinguish among single or point of use demand water heaters, whole-building water heaters, when or how to use a gang of multiple instant water heaters, & the location of tankless water heaters outdoors vs. indoors.
Tankless or demand water heaters are also referred to as point-of-use water heaters when installed close to the fixtures or bath or kitchen where used.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
List of Typical Tankless Water Heater Applications
A single point of use tankless water heater is installed where a boost in hot water temperature is needed such as
Long pipe runs, slow hot water: In a building with long water piping runs the heat loss during delivery of hot water to distant fixtures as well as the delay in delivery of hot water are eliminated if a point of use tankless water heater is installed.
If your concern is only the hot water delivery time,
High temperature applications: such as in restaurants, food processing, or other facilities where dishwashing requires a specific and high hot water temperature
Sketch of a point of use tankless water heater shown above was provided courtesy of Carson Dunlop Associates, a Toronto home inspection, education & report writing tool company [ carsondunlop.com ].
Single point of use tankless water heater
Limited hot water need: To support limited-requirement hot water flow requirements such as a low-usage restaurant bathroom
Intermittent hot water need: to support delivery of hot water that is only occasionally needed in a building, avoiding conventional water heater standby energy losses.
Home heating systems - water to air: Tankless water heaters may also be used to heat the home, either as part of a forced air combination system, or a radiant heating system.
Driveway ice melting: Demand water heaters are also used for heated driveways
Remote bathrooms or hot tubs [15]
Hot Water temperature booster
for appliances, such as dishwashers or clothes washers [15]
To address the limited hot water flow capacity of tankless hot water heaters in a building where lots of hot water is run at once people may install a large unit - which may not be the most efficient design if you do not usually run lots of hot water at many fixtures at once.
If the required hot water volume is large (serving multiple apartments or laundry facilities at once, for example) no single tankless water heater is likely to be sufficient.
Our photo (left) illustrates a Cinsa Hidro Tec instant water heater (calentador) for sale in a Home Depot in Celaya, Mexico.
Multiple or ganged tankless water heaters
Install two or more individual and smaller tankless water heaters, possibly closer to their point of use - a more efficient design but possibly with a larger equipment and installation cost.
Indoor vs. Outdoor Tankless Water Heaters
Tankless water heaters are made in models designed to be installed outdoors, exposed to weather, or indoors in a protected area such as a basement or utility room or near a point of use.
Life Expectancy & Warranty Periods for Demand, Tankless, Instant & Point of Use Water Heaters
According to the U.S. DOE,
Most tankless water heaters have a life expectancy of more than 20 years. They also have easily replaceable parts that extend their life by many more years. In contrast, storage water heaters [water heaters that use a tank to store a reservoir of hot water] last 10–15 years.[15]
Note that this analysis does not include the cost of maintenance and repair for tankless water heaters that may experience extra costs especially in areas of water that is aggressive, corrosive, or high in mineral content.
Watch out: we are doubtful of this DOE claim. In fact tankless water heaters may be particularly vulnerable to installation errors, site conditions, weather exposure, or variations in gas or water pressure to the appliance. And in areas served by water high in mineral content the water heater's life may be short without proper maintenance. [Note that some tankless water heaters such as some more costly Bosch models, are designed to withstand hard water.]
The warranty period for the Bosch 13BP low-pressure LP gas instant water heater described
Causes of Loss of Warranty Coverage on Instant / Tankless / Point-of-Use water heaters
For just about any product, a close look at the terms and conditions of the product warranty also give us clues about the product's particular vulnerabilities or limitations. So it's always worth actually reading the warranty, including that for a tankless water heater.
Watch out: the Bosch warranty described above is voided if the water heater was not installed by an authorized service technician. The company provides telephone numbers of their authorized installer or service agency right on the packaging. Nevertheless, especially as heaters may be installed at buildings remote from larger cities where Bosch maintains a service staff, it is more likely that many installations will be installed by a local plumber or even a handyman - in essence meaning that the unit has no warranty whatsoever. [4a]
Other causes of loss of water heater warranty coverage include:
Damage to the device by work performed by unauthorized service workers
Connection of the device by unauthorized service workers
Operation or maintenance of the tankless heater under conditions not described by the manufacturer's installation instructions. Examples would be installing the heater outdoors in an area not protected from rain and wind
Damage to the device caused by its transport or by malicious vandals
Failure or damage caused by inadequate gas or water pressure to the device
Failure to perform recommended maintenance or installation of components that are not original or OEM.
Watch out: to assure that your instantaneous water heater continues to perform satisfactorily be sure to perform the maintenance recommended by the manufacturer. Particularly in areas where water is high in mineral content, de-scaling the water heater will be required at intervals determined by the amount of use the appliance receives.
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Questions & answers or comments about the best or most effective use of tankless water heaters, demand water heaters, & point of use water heaters & about tankless or demand water heater life & warranty periods.
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted. Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
[1] Thanks to Mark Cramer, Tampa Florida, for assistance in technical review of the "Critical Defects"
section and for the photograph of the deteriorating gray Owens Corning flex duct in a hot attic. Mr. Cramer is a Florida home inspector and
home inspection educator.
[3] HREF="http://www.consumerreports.org/">Consumer Reports offers an article on the efficiency versus the economy of tankless water heaters - see http://www.consumerreports.org/cro/Appliances/heating-cooling-and-air/water-heaters/tankless-water-heaters/overview/tankless-water-heaters-ov.htm
[4a] Bosch, "Instrucciones de instalacion y manejo, Calentador de agua instantaneo, Confort / Confort S 6BP / 6BP n 10BP / 10BP N 13BP / 13BP N"
Robert Bosch, S. de R.L. de C.V., Calle Robert Bosch 405, Zona Industrial, Toluca, Edo de Mexico CP 50070, website: www.bosch.com.mx, Tel: 800-11-26724 (2010)
[14] U.S. Department of Energy on Tankless Water Heaters - http://apps1.eere.energy.gov/consumer/your_home/water_heating/index.cfm/mytopic=12820
[15] "Tankless or Demand Type Water Heaters,"
U.S. Department of Energy, retrieved 10/14/2012, original source: http://energy.gov/energysaver/articles/tankless-or-demand-type-water-heaters [Copy on file as Tankless_Water Heaters_DOE.pdf]
[16] Solar Water Heating, U.S. Department of Energy, retrieved 10/14/2012, original source: http://energy.gov/node/367417