Hot water temperature improvement:
This article explains how to diagnose & improve the hot water water temperature that is too cool, and how to check water temperature safety in a building.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Here is a list of what to check when your domestic Hot Water Temperature is Too Low - What to Do When the "Hot Water" is Not Hot Enough:
If your hot water temperature is just not ever hot enough here are some things to check:
Check the water temperature settings on the water heater control. You can increase the water temperature setting, but beware of scalding.
See MIXING / ANTI-SCALD VALVES for a discussion of the installation and use of anti-scald valves to avoid hot water burns, and for a table of temperatures at which hot water burns occur.
The temperature control on the gas fired water heater shown in our photo at left has been set to "Low" and could be turned "up" to a hotter temperature if building hot water is found to be too cool.
Long hot water piping runs can mean not enough or not hot enough hot water, especially if the piping runs through cold walls, basements, crawl spaces, or attics
If this is the cause of water not being hot enough, the problem will not usually occur suddenly, but it will vary by season, with "hot" water being "cooler" in cold weather.
Even sudden appearance of hot water running cooler could be caused by uninsulated water pipe runs if the water pipes happen to be located in an area normally protected from weather but suddenly left exposed, such as a basement door left open or a mobile home surrounding skirt falling off..
If the water is leaving your water heater at a high temperature but arriving too cool at the sink, shower, or tub, see Insulate Hot Water Piping for details.
(Sketch courtesy Carson Dunlop Associates ) at your water heater tank. If your water is heated by an electric, gas, oil, or even solar-heated water tank, the tank probably uses a dip-tube to direct incoming cold water to the bottom of the hot water tank.
If the dip tube is leaking (metal dip tubes are often intended to corrode) it may be leaking incoming cold water into the top of the water heater tank.
Or the dip tube may have corroded away or dissolved completely, or parts of it may have fallen into the water heater tank.
See WATER HEATER DEBRIS FLUSH for an example of a dip tube that dissolved and fell into the water heater interior.
Either of these dip tube problems means that cold water running into the water heater tank is no longer delivered to thte tank bottom. Rather it enters at the heater tank top where it mixes with and cools the "hot" water in the water heater.
Watch out: another water heater defect can also result in hot water that's not hot enough.
If the dip tube in the water heater has fallen off or disintegrated, cold water will enter the water heater at its top rather than at its bottom.
The result will be constant dilution of the hottest water in the heater (at its top) with incoming cold water. The result is that the hot water may be just tepid, not hot enough, though the total quantity of hot water is unchanged.
Watch out: a bad dip tube OR a burned out electric water heater lower heating element both give the symptom of tepid hot water output.
So test the lower water heater element and also inspect for debris coming out of the water heater; debris from hot water piping clogging a sink strainer might be traced to a deteriorated tip tube. .
Thanks to Carson Dunlop Associates, a Toronto Home Inspection Firm and to Alan Carson, a Home Inspection Educator, for permission to use sketches shown in this article.
Details about water heater anodes and dip tubes, how they work and why they are needed, are
at ANODES & DIP TUBES on WATER HEATERS.
if your water heater is electric it probably has two heating elements, an upper and a lower unit. It's easy to diagnose a bad electric water heating element, and you can suspect a problem with the heating elements in an electric water heater even before doing any testing: (Sketch courtesy Carson Dunlop Associates )
If the hot water coming out of the electric water heater is hot but runs out more quickly than previously, we suspect that the lower heating element has burned out.
The upper water heating element is heating up just the water in the top of the water tank. So you have just a small amount of hot water before you run out.
If the hot water coming out of the electric water heater has become tepid when it used to be hot (and no one has changed any other hot water settings), we suspect that the upper heating element has burned out.
When only the lower heating element in an electric water heater is working, it will warm the water but it will normally be unable to raise the temperature in the whole water tank to a high enough level.
So you have plenty of tepid "hot" water.
Watch out: as we described just above, a failed water heater dip tube also causes "hot" water to come out tepid or at a lower temperature than normal.
Oil fired heating equipment, when properly adjusted, does not burn perfectly clean.
Burning heating oil produces soot which over time sticks to the interior surfaces of the water heater's interior.
There the soot acts like an insulator, reducing the transfer of heat from the burning heating oil through the metal of the water heater's heat exchanger, into the hot water itself.
You may have plenty of water but its temperature is not as hot as it used to be.
Often service people called to clean and tune an oil fired heating boiler do not clean and adjust the oil-fired water heater unless specifically asked (and paid) to do so.
Just as your oil fired furnace or boiler should be serviced annual (for safety and to lower heating costs), so should your oil-fired water heater be cleaned and tuned annually.
It's likely that this service will be earned back easily in reduced heating oil costs.\
See HOW TO CUT HEATING COSTS for details.
Check the temperature settings at the mixing valve installed on your water heating system.
See MIXING / ANTI-SCALD VALVES for a discussion of the installation and use of anti-scald valves to avoid hot water burns, and for a table of temperatures at which hot water burns occur.
At the top of this page we show a photo of a mixing valve on a heating boiler.
Check the temperature settings at the aquastat combination control if your hot water is made by a tankless coil on a heating boiler.
The "low limit" control shown in our photograph at left maintains hot water in the heating boiler to assure that the tankless coil can produce domestic hot water.
During the heating season, the "high limit" will control boiler operation and boiler temperatures will normally be hotter than what was set here at the "LO" control.
See MIXING / ANTI-SCALD VALVES for a discussion of the installation and use of anti-scald valves to avoid hot water burns, and for a table of temperatures at which hot water burns occur.
Setting water temperature above 100 degF may cause serious scalding burns.A.O. Smith, the manufacturer of this water heater warns about water temperatures over 125 degF.
See MIXING / ANTI-SCALD VALVES for a discussion of the installation and use of anti-scald valves to avoid hot water burns, and for a table of temperatures at which hot water burns occur.
See SCALDING TEMPERATURES & TIMES for details about how long it takes to be injured in hot water of different temperatures.
As we discussed beginning in the previous section of this article, there are several different hot water problems:
As we warn in more detail below, setting the water temperature too high can cause dangerous, even fatal scalding burns. Yet many of us (author DF included) often set the water heater thermostatic control to a high number.
Why?
Because the hot water delivery piping distance between the water heater or calorifier and the point of use plumbing fixture varies in a building and because by the time hot water reaches its destination it may be too cool.
A second reason we set the water heater output temperature to a high number is to increase the total volume of hot water available at the plumbing fixcture. If your water heater is small in capacity you may not be able to fill a large bath tub with enough hot water to satisfy building occupants.
A "solution" is to increase the temperature of hot water supplied to the tub, mixing it there with enough cold such that the total volume of hot-enough water will also be sufficient.
But the result can be scalding burns especially when people unfamiliar with the home use that plumbing fixture.
A proper, safe solution to "not enough hot water" can be obtained by increasing the water heater output temperature but also including an anti-scald device either at the point of use or at the water heater itself.
See ANTI_SCALD VALVES & HOT WATER QUANTITY
Depending on the type of water heater, cylinder or calorifier that you use and its fuel: electric, gas, oil, solar, the controls that manage hot water temperature will vary.
...
Continue reading at ELECTRIC WATER HEATER THERMOSTATS for electric water heaters or water cylinders, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see WATER HEATER TEMPERATURE TOO COLD or TOO HOT FAQs - questions and answers posted originally on this page
Or see these
WATER HEATER TEMPERATURE TOO COLD or TOO HOT at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.