Water Pump Prime Procedure FAQ
Q&A on how to prime the well pump & how to diagnose & fix repeated loss of well pump prime:
This article series describes how to prime a water pump to restore water pressure to a building.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
These questions and answers about troubleshooting a pump that keeps on losing prime were posted originally at PUMP PRIME, REPEATED LOSS - be sure to review that article.
Also see our index to all Q&A about priming a pump at WATER PUMP PRIMING DIAGNOSTIC FAQs
...
Tip: See PRIME the PUMP, HOW TO
Hi. I have read the article on losing prime and have been very grateful for all of the information on the site.
I'm new to wells and still would like some more experienced opinions. I have a well with a low flow that pumps into a below-ground 6000 gallon reservoir which is then jet-pumped into my two above ground pressure tanks.
Recently, I have lost prime on it a couple of times. If I leave the system idle for 24 hours don't use any water, when the jet pump kicks in there is a discharge of air and then the water pressure returns. Where is the air coming from? Is something going faulty?
There is a screw cap located on the line between the foot in the reservoir and the check valve before the jet pump where I can fill the intake up with water before priming the pump from the output. When I fill the intake I can see the water level drop a little after 10 minutes.
Does this mean I have a bad foot valve or when the cap screw is replaced should the check valve at the pump prevent the water level drop? Sorry for the long description.
On 2018-12-12 by Bryan
by (mod) - you need to find the leak in piping, at a foot valve or check valve, or at the pump itself
When priming a pump it's normal for water to go down in the pump chamber as water flows out into the well pipe - which also needs to be filled as part of the priming process.
But once you've put enough water into the system to fill both pump and well pipe(s), then if the level keeps dropping, there's a leak somewhere in the pipe, foot valve, or even right at the pump.
So how much water should be enough to prime the pump?
The answer is one we can calculate, as I explain at WATER VOLUME NEEDED to PRIME THE PUMP - how much water will you need?
As you keep losing prime it's probably one of the causes in the article
The natural place to start is by looking for a bad check valve for leak in the water piping. You could also have a leak in the pump body itself.
Find the leak.
Our well and pump work fine after I found and fixed the leak
Thanks for all of your help. I fixed the small, (very small), leak in the output and the well has now been functioning flawlessly for 4 days. I'm still concerned that the level drops in the pipes when I prime it but it doesn't seem to affect the operation at the moment. I'll leave it until I need to address it. Thanks again.
I was about to say I've checked those places, but I went and checked again and there was a tiny leak in the output pipe. I fixed that by tightening it, snapping the PVC joint and rebuilding that section of pipe
....oh boy. .....
.So now I am waiting to see if there are any more leaks.
There still is, however, a noticeable drop in the water level when I am priming the pump and no conspicuous water leaking out. Does that bring me back to the check and foot valve? How long should these valves hold the water in the pipes?
Minutes/days? Since I am seeing the water drop where I fill the line on the output, does that point to a failing check valve, (much easier to replace)?
Thanks again. On 2018-12-17 by Bryan
...
Continue reading at PUMP PRIME, REPEATED LOSS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
PUMP PRIME PROCEDURE, WATER LEVEL DROPS Q&A at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.