Sewer Line Replacement Procedure - final backfill
This article describes the final backfill stage when a sewer pipe or "drain line" is replaced.
The line which was replaced in this photo-illustrated case runs from the building exterior to a septic tank located downhill from the home.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
We present an actual case study, illustrated with photos of each step in the diagnosis and replacement of a blocked sewer line. Technical reviewers are welcome and are listed at "References."
After the drain pipe was fully bedded on and under sand,
the excavator proceeded to backfill the remainder of the trench by pushing the excavated soil back in place. A skilled excavator can leave the site "rough graded" into a pretty smooth surface.
In this case a little work with an iron rake and some grass seed and the yard surface was back in acceptable condition. We bought a fast-growing fall-seeding grass seed so that grass would grow quickly so as to avoid erosion on the sloped rear yard, and we used some mulch to help hold the new seed in place until grass had sprouted.
The excavator took advantage of the backfill time to crush and bury piping scraps and debris from the excavated old sewer line. However we collected some of the larger debris, rubber and metal scraps, or other suspect items that had turned up during excavating (including a 1920's vintage automobile tire) to be hauled to a proper disposal site instead of permitting them to simply be buried on this residential property.
The final grading over a sewer lineor any other septic piping system (such as drainfield trenches) should be left slightly mounded to accommodate the natural settlement of disturbed soils without leaving a trench or depression in the yard surface.
We picked out plastic and other large debris items that the client did not want to discover later in the property's soil. Some of these materials, such as broken sections of abandoned used sewer piping may involve sharp edges or bacteriological hazards and should be disposed-of appropriately.
...
...
Continue reading at DOCUMENT BURIED COMPONENT LOCATION or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
FINAL BACKFILL SEWER LINE TRENCH at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Search the InspectApedia website
Need to make a private comment? Email editor@inspectApedia.com. We welcome email with your website content critique, corrections, suggestions or questions. Email is monitored daily but our workload may prevent an immediate reply. For immediate results, we hope you'll first try asking your question using the search box just above.
In addition to any citations in the article above, a full list is available on request.