Effects of chlorine disinfectants on septic systems, wastewater & drainfields or soakbeds:
What concentration of chlorine will kill septic bacteria? How does chlorine get into a private septic system? Is it a problem? When are chlorine or other disinfectants needed for aerobic or other septic systems? Will septic tank chlorine damage the septic tank or leach fields?
This article series explains how to extend the life of the septic system by being careful about what goes into it.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
In locations where wastewater effluent must be sanitized by chemical treatment before it is discharged to the environment, chlorine products and various dosing methods may be used in some system designs. For example some sand bed filtration systems produce effluent that is treated with chlorine injection before the final discharge of effluent to the environment. .
These are alternative septic system designs which are intended to be chemically treated including using disinfectants such as calcium hypochlorite or chlorine.
The previous section which discussed water chlorinators for drinking water does not normally pertain to chlorine-dosing septic systems.
(Feb 15, 2015) Mo said:
drinking water system officials won't disclose mistaken chlorine residual rate that was high enough to kill biotic action in septic systems. We believe it occurred over a 6 month period, April to September, which is when I discovered and reported our systems failures.
I do not know when the others were discovered.
I would like to know how high the chlorine residual must be to kill the biotics in a septic system. I understand there will be variables, but please consider a home with three occupants performing all typical waters uses.(Another home experiencing failure had six occupants)
Mo
According to the US EPA, the level of chlorine needed to disinfect clarified wastewater effluent ranges between 5 and 20 mg/L.
The required degree of disinfection can be achieved by varying the dose and the contact time for any chlorine disinfection system. Chlorine dosage will vary based on chlorine demand, wastewater characteristics, and discharge requirements. The dose usually ranges from 5 to 20 mg/L. - U.S. EPA Wastewater Technology Fact Sheet, Disinfection for Small Systems (ret. 2015)
But this is hardly the end of the story. To have objective and thus defensible data you'd need to know the concentration of cholorine in your wastewater system. The level of disinfectant (and exposure time) to disinfect wastewater effluent discharged from a conventional septic system varies depending on at least these other factors (some of these are only of minor import):
At BLEACH DISINFECTANT for DRINKING WATER we give information about how much bleach is needed to kill bacteria in water to make it potable.
This is a significantly higher level of disinfection than for wastewater as it is necessary to kill nearly all pathogens in the water to make it safe to drink. In this case, which could be taken as the upper limit when trying to understand how much chlorine would be needed to effectively kill off the necessary soil bacteria and biofilm in an onsite wastewater system or septic system, the bleach levels would be higher for cloudy or debris-containing water than for normal drinking water, and higher still for sewage - almost impossible.
When treating drinking water we use about 10 drops of 1% bleach or 2 drops of 4-6% chlorine bleach per quart of water.
One liquid drop (varying by liquid viscosity and other factors) is about 0.025 cc or 0.0009 fluid ounces.
One Quart contains 32 fluid ounces.
At 2 drops per quart that's (2 x 0.0009 oz) or 0.0018 oz of household bleach per 32 oz of clear water, or approximately a concentration of 0.0018 / 32 = 0.00005625
or converting this to a percent and ignoring the added volume of the droplets to the total volume, that's 100 x 0.00005625 = 0.005625% solution.
As you can read in various expert sources, disinfecting wastewater is not easy.
For optimum performance, a chlorine disinfection system should provide rapid initial mixing and a plug flow contact regime.
The goal of proper mixing is to enhance disinfection by initiating a reaction between free chlorine and ammonia nitrogen. This helps to prevent free chlorine from reacting with organic carbon compounds and forming hazardous byproducts. In order to allow appropriate time for the disinfection reaction, the contact chamber should be designed with rounded corners to eliminate dead flow areas.
It should also be baffled to minimize short-circuiting. This design allows for adequate contact time between the microorganisms and a minimal chlorine concentration for a specific period of time. - Op. Cit.
Keep in mind that this is for clear water. The level of microbial contaminants in sewage is enormously higher so that the concentration of bleach needed to kill all of the bacteria alone would be a much much greater amount. For example, Caldwell (1946) pointed out that you'd need 10 ppm of chlorine to kill algal sells in a wastewater pond.
For aerobic septic systems which must use a disinfectant stage, see our article on what disinfectants to use (not pool chlorine tablets)
at AEROBIC Septic Systems Final Treatment Stage
More about the effects of chlorine (or bleach) on wastewater and the environment is
at WASTEWATER BIOCOMPATIBILITY.
Below is our informal analysis in reply to this interesting question from a reader. The reader proposed backwashing a swimming pool into a large septic tank and an unknown drainfield size, using two alternative load levels which we describe as two options.
Note: The author (D Friedman) is not a septic design engineer. The following comments are opinion based on research and experience and should be amended by a septic engineer and adjusted for the specifics of your particular case.
Option 1: backwash at 355 gpm and produce 5000 gals of waste 2-3 times per week. Chlorine levels are expected to be at 2ppm
5000 gallons of wastewater at 2 ppm chlorine dumped into a 10,000 gallon tank at 355 gpm would mean running that volume of water into the tank in about 15 minutes. Your septic tank will reach about 1 ppm of chlorine at that rate before it is further diluted by other wastewater.
A concentration of 1 ppm chlorine in a septic tank is unlikely to kill all of the septic tank and drainfield bacteria off severely immediately but over time may reduce the total bacterial activity.
We need 10 ppm (10 mg/L) concentration of chlorine in water with an exposure time of 30 minutes to kill virtually all Giardia and bacteria in water; that time needed would be increased for cloudy turbid water (in a septic tank), for higher pH water, and for cold water. -- OSU
There is a risk that putting such a large volume of water from a swim pool into a septic tank or onto the drainfield would ruin the septic system.
High entry rate in gpm of water into the septic tank is also likely to be a problem. Pumping wastewater into the septic tank at 355 gpm is also likely to be a much faster rate of water insertion than normally occurs from a residential building served by a septic tank. This surge and flow rate may agitate the septic tank contents, increasing the level of suspended solids significantly.
A typical residential septic tank and drainfield are designed to receive about one tenth of the pool backwash volume twice a day - or about 1000 to 1200 gallons a day.
See details at WATER QUANTITY REQUIREMENTS
and see the TABLE of SEPTIC TANK SIZE REQUIREMENTS
5000 gallons of water into a tank during one day is about the same as the wastewater usage from perhaps 50 people in a building. That is 2 ½ times the expected usage level for a 5000 gallon septic tank.
High volumes of water from a swimming pool into a septic tank will also flood the tank and prevent proper processing of the waste therein. Flooding a septic tank means that the users are pushing a high level of suspended solids, abnormally high in addition, out into the drainfield - there is not enough settling time -shortens the drainfield life or ruins it promptly.
High volumes of water from a pool backwash onto a drainfield will flood the field and prevent proper processing of the septic tank effluent that is meant to be discharged there.
You would have to tell me that your septic engineer designed the drainfield to handle surges in wastewater volume at a level equal to the sum of the usage load from the building it serves plus the swimming pool. I'd be surprised if someone were willing to foot the bill for such an over design - some sites won't have sufficient space for a working drainfield of the size needed to handle what amounts to a more than 50 person load.
Spreading out the load by only backwashing every other day or two is unlikely to be sufficient to allow the tank or field to recover.
You should not discharge swimming pool backwash into a septic tank. Doing so will flood the tank and push solid waste into the drainfield and there may be some temporary reduction in the bacterial activity, reducing the treatment level in the septic tank and thus increasing the BOD and suspended solids.
You should not discharge swimming pool backwash anywhere within 100 feet of a drainfield. Doing so is likely to saturate the soil, interfere with drainfield treatment of septic effluent, and possibly harm soil bacteria.
Option 2: gravity for a total load of 320 gals per month. Chlorine levels are expected to be at 2ppm.
A once a month additional load of 320 gallons into a septic tank, especially a large 5000g unit, is the equivalent of about 3 more people of load once a month - which should not be a significant percentage increase in load compared to the design level of a 5000 g tank.
The chlorine load of swimming pool water at 2 ppm may have a small impact on bacteria in the tank but at an infrequent insertion is unlikely to have any lasting impact so long as the system is also in normal use as a septic tank receiving black water from a building.
As above, a once a month additional load of 320 gallons into a septic tank, especially a large 5000g unit, is the equivalent of about 3 more people of load once a month - about the same as having a few visitors for a weekend. I would not expect the water volume to have a significant impact on the system.
In general it is better for a septic system to reduce rather than increase the water load into the tank and drainfield. If the septic tank were a typical residential 1000g or 1200g tank, the impact of these wastewater loads could be significant.
At WELL CHLORINATION & SHOCKING we describe the procedure for sanitizing a drinking water well. This procedure is used following certain well, pump, or plumbing repairs and it is often used in a first-stage attempt to diagnose (and on occasion "cure") bacterial contamination of well water.
For a 100' deep well column of water (that is 100' of water is in a 6" steel casing - we don't care the actual well depth, just the amount of water in the well) we suggest using 3 cups Clorox™ to shock the well.
Actually when you are running water into a building as part of flushing out and sanitizing a well, the volume of water being treated is greater as you are drawing water out of the well, more water is running into the well from the earth, and that more dilute solution is entering the building water tank and piping.
Commercial "chlorine" bleaches usually contain 3 to 6% sodium hypochlorite (NaClO). Some bleaches also contain detergents and thickening agents, and other oxygen bleaches using hydrogen peroxide do not contain any chlorine and are based on peroxy-compounds. Bleach in sufficient concentration and at sufficient exposure time will kill bacteria (by attacking certain proteins in the bacteria) and some other pathogens. The temperature of the water-bleach solution also impacts the necessary exposure time (colder means you need longer exposure for the disinfectant to be effective).
At DRINKING WATER - EMERGENCY PURIFICATION we discuss procedures for purifying drinking water, and the concentration of disinfectant needed. There we suggest that 8 drops of bleach will purify one gallon of water.
A 100 foot deep column of water in a standard 6" well casing will equal about (1.5 gpf x 100) 150 gallons of water.
So the health department rule of thumb that suggests we use 3 cups of bleach to shock a 100 foot deep well means we are using a concentration 12 times stronger than we would just to produce drinking water. (700 /150) x 3 cups.
This extra strength chlorine solution must be intended to accommodate disinfection of contaminated surfaces in the well casing, the pump, the piping, water tank, and fixtures, and to handle the dilution that occurs when we run water through the building plumbing system in the well shock procedure.
To look at the effect of shocking the well on a septic tank, let's guess that we dilute the disinfecting solution not at all.
When we flush out the water system after shocking the well let's put about our 150 gallons of water right into a typical 1,500 gallon septic tank, without allowing for the additional dilution that will actually occur as we continue to run water out of our well and through the plumbing system until we no longer smell any chlorine at our sink faucets.
Our 150 gallons is joining a volume ten times larger (1,500 gallons) in the septic tank, so it is diluted by a factor of ten - we're back to a level close to the sanitation of normal drinking water.
Our dilute chlorine solution in the septic tank is further weakened by
Finally, considering that the concentration of sewage bacteria in the septic tank is enormously more than the original concentration of bleach in drinking water could have purified, it is not at all likely that following normal well shocking procedures would damage the septic system due to its chlorine concentration.
Details about the effects of chlorine (in bleach for example) on soils and on ocean bodies or freshwater bodies are
at WASTEWATER BIOCOMPATIBILITY.
(May 26, 2011) Anonymous said:
can you use clorine bleach
If you are asking if it's ok to use chlorine bleach at normal usage levels while doing laundry, yes that should not be a problem.
(Aug 5, 2011) Don Winters said:
Is it advisable to use dishwasher detergent that contains chlorine or would it be better to avoid chlorine as much as possible in a septic system? I thought septic systems relied on bacterial action and it seems that chlorine could inhibit such action.
Don, at normal household usage levels the chlorine in dishwasher detergent won't harm the septic system. Search InspectApedia for TOILETS, DON'T FLUSH LIST - for more detail.
(Oct 31, 2014) Anonymous said:
Hi Don, What do you consider normal levels from a dish machine?
Reply:
Anon:
The use of manufacturer-recommended dishwasher detergent products in the recommended doses should not harm the system. The physical quantity recommended varies a bit by product and whether it's a liquid or powder.
(Oct 24, 2011) Gerry S said:
If chlorination kills harmful bacteria in drinking/tap water, why does it not kill the organisms in a septic tank/system as well?
Gerry the ability of chlorine to kill bacteria depends on its concentration and the duration of exposure of the bacteria to the chlorine solution. In a septic tank, at normal use levels, the concentration of household bleach is not enough to kill bacteria.
(Dec 9, 2012) clyde pearce said:
I am currently on a Well/Septic System. A new water plant is offering to pipe treated/chlorinated water to our home. Will the chlorine in the treated water ruin my septic system?
Not at normal concentrations.
(Feb 29, 2016) Anonymous said:
Why is the pipe I put my bleach in full?
Sounds as if your septic tank or outlet piping or drainfield are blocked or flooded.
...
Continue reading at CHLORINE IMPACT on SEPTIC or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
CHLORINE SOURCES in WASTEWATER at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.
Chlorine kills bacteria, including disease-causing organisms and the nuisance organism, iron bacteria. However, low levels of chlorine, normally used to disinfect water, are not an effective treatment for giardia cysts. A chlorine level of over 10 mg/1 must be maintained for at least 30 minutes to kill giardia cysts. -- http://ohioline.osu.edu/b795/index.html is the front page of this bulletin.